Metrologic Instruments MS863 user manual

User manual for the device Metrologic Instruments MS863

Device: Metrologic Instruments MS863
Category: Barcode Reader
Manufacturer: Metrologic Instruments
Size: 1.11 MB
Added : 10/2/2014
Number of pages: 52
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Metrologic Instruments MS863. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Metrologic Instruments MS863.

For your convenience

If looking through the Metrologic Instruments MS863 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Metrologic Instruments MS863 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Metrologic Instruments MS863 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Metrologic Instruments MS863 User manual - Online PDF
Advertisement
« Page 1 of 52 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Metrologic Instruments MS863 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Metrologic Instruments MS863. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

METROLOGIC INSTRUMENTS, INC.
MS860 / MS863 Mini-Slot
Laser Bar Code Scanner
Installation and User’s Guide

Summary of the content on the page No. 2

Summary of the content on the page No. 3

LOCATIONS Corporate Headquarters North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com European Headquarters Germany, Metrologic Instruments GmbH Tel: +49 89 89019 0 Middle East and Africa Dornierstrasse 2 Fax: +49 89 89019 200 82178 Puchheim b. Email: info@europe.metrologic.com Munich, Germany Germany Email: info@de.metrologic.com Spain Met

Summary of the content on the page No. 4

TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Scanner Connections to the Host......................................................................... 3 Configuration of the Scanner to the Host System................................................. 4 Cloning Feature............................

Summary of the content on the page No. 5

INTRODUCTION Metrologic's MS860 and MS863 laser bar code Scanners are high-speed, aggressive in-counter scanners. Both models have compact, durable housings for use with applications where counter top space is limited. The MS860 and MS863 autodiscriminate all standard bar codes. Each model © includes a code-correcting feature (MECCA ) that enables the scanner to decode damaged or truncated codes on the first pass. Both models can be programmed ® by using the bar code menus from the ScanSelect

Summary of the content on the page No. 6

SCANNER AND ACCESSORIES • MS860 or MS863 Laser Bar Code Projection Scanner • Installation and User’s Guide ....................................................MLPN 00-02202 ® • ScanSelect Scanner Programming Guide ...............................MLPN 00-02186 • Volume Control Card .................................................................MLPN 00-02346 • Installation Plate for MS860 models only ...................................MLPN 45-45471 Optional Accessories • Power Supply ............

Summary of the content on the page No. 7

SCANNER CONNECTIONS TO THE HOST To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the 25-pin D-type connector on the scanner’s head cable to the communication cable. 3. Connect the other end of the communication cable to the host device. 4. If the scanner will not receive power from a transformer, skip to Step 5. If the scanner will receive power from an external power source, check the AC input

Summary of the content on the page No. 8

CONFIGURATION OF THE SCANNER TO THE HOST SYSTEM The MS860/MS863 is shipped from the factory programmed to a set of default conditions noted in the Default Settings section of this guide and in the ® ScanSelect Scanner Programming Guide provided. The default settings in the ScanSelect guide have an asterisk that appears before the brief definition next to the bar code. Since each host system is unique, the scanner will need to be configured to ® match the specific host system’s requirements. If

Summary of the content on the page No. 9

CLONING FEATURE The cloning feature is used to program several scanners with the same settings. To clone a scanner: 1. Turn OFF the power to both scanners by unplugging the transformers. 2. Connect the cloning cable (MLPN 51-51544) between the two scanners. 3. Turn ON the power to both scanners by plugging in the transformers. 4. When each scanner is ready, scan the cloning bar code with the scanner that has the settings that need to be transferred to the other scanner. CLONING 0 12345 77777 6

Summary of the content on the page No. 10

VERSION 11 IBM 46XX SCANNER Output Format: IBM RS-485 serial input/output for the 4680 and 4690 (46XX) point-of-sale terminals The Version 11 46XX interface can be used in several different ways. Both the 46XX terminal and the scanner must be configured to match each other. Warning: Power to the scanner and 46XX terminal should be turned off before making physical connection. The 4680 and 4690 series terminals have different types of physical ports for connecting bar code scanners. Scanner port

Summary of the content on the page No. 11

CONFIGURING THE MS860-11/MS863-11 SCANNER Located in the Version 11 scanner are two computer boards. One computer board is for decoding and the other for 46XX IO processing. The decode board is configured using ScanSet or ScanSelect while the IO board is configured with an internal DIP Switch bank. For UPC/EAN scanning, the decode board should be set as follows: Enable IBM 4680 Communication Enable UPC/EAN Beep after Transmit Enable Communication Timeouts Transmit UPC-A Check Digit Transmit U

Summary of the content on the page No. 12

CONFIGURING THE IBM 46XX The 4683 and 4693 terminals are configured on the store controller. The 4684 and 4694 terminals are typically configured on the individual terminals. Follow the appropriate guide for your type of equipment. IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Running 4680.OS or 4690.OS Access the terminal configuration menu on the store controller. If not already selected, select an IBM 1520 laser hand scanner (4680.OS Port 5B), an IBM 4500 hand-held bar code

Summary of the content on the page No. 13

VERSION 17 KEYBOARD WEDGE SCANNER The MS860/MS863 scanner (version 17) provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. The following are the supported keyboard and country types: PC Type • AT (includes IBM PS/2 and compatible models 50, 55, 60, 80) • XT • PS/2 (includes IBM PC and compatible models 30, 70, 8556) Keyboard Country Type • USA • Germany • France • Spain • Italy • Belguim • United Kingdom • Swiss With the appropriate commun

Summary of the content on the page No. 14

CONNECTION OF A MS860-17 SCANNER TO A PC 1. If the PC is on, exit your application and turn the PC off. 2. Disconnect the keyboard from the PC. Plug the Keyboard Wedge cable to the PC and the keyboard. Use the adapter cable if necessary. 3. Connect the 25-pin D-type connector on the scanner’s head cable to the Keyboard Wedge cable. 4. Check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. A socket outlet should installed near the equipment and be e

Summary of the content on the page No. 15

OPTIONAL IN-COUNTER MOUNTING OPTIONS FOR THE MS860 Metrologic has designed three plates to accommodate in-counter installation of the MS860. Included automatically with the purchase of the MS860 is Metrologic part #45-45471, Installation Plate. The universal and replacement plates are available for an additional charge. Contact the distributor, dealer or Metrologic customer service representative to order one of these plates. Metrologic Part Number mlpn 45-45471, Installation Plate: This plat

Summary of the content on the page No. 16

VERTICAL STAND KIT Vertical Stand Kit, MLPN 45-45472 includes: a. Vertical Stand [ MLPN 45-45472 ] Qty. 1 b. #6-32 x 3/8” Phillips Head Screw [ MLPN 18-18317 ] Qty. 2 c. #8 x 1.00” Round Head Wood Screw [ MLPN 18-18057 ] Qty. 3 Installation Orientation Note: The arrow on the top of the scanner indicates the direction that items must be presented to the scanner. 1. Drill four #39 pilot holes into the counter top (See Figure 2). 2. Screw the stand to the counter top with the four #8 wood screws

Summary of the content on the page No. 17

SCANNER PARTS Touch Plate When a specified time has elapsed without any scanning, the unit will enter a “standby” mode. Touching the touch plate arrow on the top cover will reactivate the scanner. Red LED When the red LED flashes ON, the scanner has read a bar code successfully. When the red light turns OFF, communication to the host is complete. Green LED When the green LED is ON, this indicates the unit is receiving power and the laser is ON. Output Window This aperture emits laser lig

Summary of the content on the page No. 18

The MS860 TOUCH PLATE The MS860 will enter “standby” when it remains dormant for a time. When the scanner’s computer is on “standby," touching the touch plate will “wake up” the scanner and activate the laser. When the green LED comes on, the scanner is powering up for full operation. After approximately three seconds, the scanner will be ready to operate. The default touch plate timeout is ten minutes. However, this can be changed through ScanSet or by scanning a bar code in Section C of th

Summary of the content on the page No. 19

VISUAL INDICATORS There is a red and green LED at the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the scan and scanner. Steady Green When the laser is on, the green LED is also on. This occurs when the touch plate has been touched. The green LED will remain on until the touch plate timeout elapses or until the scanner turns off. Steady Green; Red Flash When the scanner successfully reads a bar code, the red LED will flash

Summary of the content on the page No. 20

VISUAL INDICATORS Signaux optiques Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous informent sur l'état du scanner. Ni la diode rouge, ni la diode verte n'est allumée Il existe deux raisons possibles pour que les diodes ne s'allument pas. Premièrement: si le scanner reçoit de l'énergie sans que les diodes ne s'allument, le scanner est resté sans servir pendant un


Alternative user manuals
# User manual Category Download
1 Metrologic Instruments IS1000 User manual Barcode Reader 7
2 Metrologic Instruments FOCUSE IS1650 User manual Barcode Reader 7
3 Metrologic Instruments 8 User manual Barcode Reader 1
4 Metrologic Instruments QUANTUME IS3480 User manual Barcode Reader 8
5 Metrologic Instruments VOYAGERGS MS9590 User manual Barcode Reader 57
6 Metrologic Instruments VOYAGER MS9530 User manual Barcode Reader 6
7 Metrologic Instruments MS5100 User manual Barcode Reader 7
8 Metrologic Instruments IS4220 User manual Barcode Reader 8
9 Sony BRAVIA KDL-20S2020 User manual Barcode Reader 73
10 Sony BRAVIA KDL-20S2000 User manual Barcode Reader 35
11 Philips 3121 233 42852 User manual Barcode Reader 0
12 Philips GoGear SA2526 User manual Barcode Reader 0
13 Philips SA2540 User manual Barcode Reader 0
14 Philips SA2516 User manual Barcode Reader 0
15 Philips SA2520 User manual Barcode Reader 0