Honeywell NIAGARA CP-700 user manual

User manual for the device Honeywell NIAGARA CP-700

Device: Honeywell NIAGARA CP-700
Category: Barcode Reader
Manufacturer: Honeywell
Size: 2.16 MB
Added : 10/2/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell NIAGARA CP-700. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell NIAGARA CP-700.

For your convenience

If looking through the Honeywell NIAGARA CP-700 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell NIAGARA CP-700 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell NIAGARA CP-700 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell NIAGARA CP-700 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell NIAGARA CP-700 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell NIAGARA CP-700. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

WEB-700
WEB-700-O
CP-700
INSTALLATION INSTRUCTIONS

APPLICATION
The WEB-700 and CP-700 are compact, embedded
controller/server platforms that allow integrated control and
management of external devices over the Internet. They
provide suppport for two optional communications boards as
well as optional remote I/O expansion modules.
CONTENTS
About This Guide 2 External 12V Backup Battery 18
Related Documentation 2 Wiring to Remote I/O Modules 19
Product Description 3 Power Up and Initial Chec

Summary of the content on the page No. 2

WEB-700 WEB-700-O CP-700 ABOUT THIS GUIDE This document covers the mounting and wiring of the Tridium® WEB/CP-700 (T-700) controller. It assumes that you are an engineer, technician, or service person who is performing control system installation. Instructions in this document apply to the following products: Model Description WEB-700 DIN mount 7 series controller, powered by separate plug-in power supply module or wall mount AC WEB-700-O power adapter. Controller supports optional remote I

Summary of the content on the page No. 3

WEB-700 WEB-700-O CP-700 PRODUCT DESCRIPTION The WEB/CP-700 controller is a compact embedded processor platform using on-board Flash memory for backup, in an expandable DIN-modular package. Designed for use in commercial environments, the WEB/CP-700 runs the NiagaraAX Framework to provide integrated control, supervision, and network management solutions for wide variety of networked field devices. NiagaraAX-3.5 or later is required. Packaging and Features The WEB/CP-700 features a DIN-mount c

Summary of the content on the page No. 4

WEB-700 WEB-700-O CP-700 . NiMH battery pack Removed and shield removed option cards Main controller board DIN-mount base with screw tabs for panel mount Connector ports Fig. 2. WEB/CP-700 main controller board and 2 option cards uninstalled. As a 7 series controller, the WEB/CP-700 uses a PowerPC 440EPx processor, 1GB Flash storage, and 1 GB DDR-2 RAM. TCP/ IP access is via two standard Gigabit Ethernet ports. Serial communications ports (RS-232, RS-485) are standard. One or two option ca

Summary of the content on the page No. 5

WEB-700 WEB-700-O CP-700 Technical Specifications WEB/CP-700 PLATFORM • PowerPC 440Epx @ 667MHz processor (speed approximate due to spread spectrum clock). • 1GB on-board NAND Flash storage. • 1 GB DDR-2 333Mhz RAM (maximum Java Heap size 384MB). • Two (2) Gigabit Ethernet ports. • Standard RS-232 port. • 6-position end connector with isolated RS-485/15Vdc power (usable as a standard non-powered isolated RS-485 port, or to support remote I/O modules). • MiniPCI option slot, for optional NPB-WIF

Summary of the content on the page No. 6

WEB-700 WEB-700-O CP-700 PREPARATION Unpack the WEB/CP-700 and inspect the package contents for damaged or missing components. If damaged, notify the appropriate carrier at once and return any damaged components for immediate repair or replacement. See “Returning a Defective Unit” on page 25. • Included in this Package • Material and Tools Required Included in this Package Included in this package you should find the following items: • WEB/CP-700 controller. • WEB/CP-700 Installation Instructi

Summary of the content on the page No. 7

WEB-700 WEB-700-O CP-700 WARNING A 120Vac or 240Vac circuit powers the NPB-PWR-UN-H power supply for the controller. 15Vdc input (DC only) to controller. Disconnect power before installation or servicing to prevent electrical shock or equipment damage. Make all connections in accordance with national and local electrical codes. Use copper conductors only. To reduce the risk of fire or electrical shock, install in a controlled environment relatively free of contaminants. This device is only inte

Summary of the content on the page No. 8

WEB-700 WEB-700-O CP-700 Physical Mounting The following information applies about physically mounting the unit. • You can mount the WEB/CP-700 in any orientation. It it not necessary to remove the cover before mounting. • Mounting on a 35mm wide DIN rail is recommended. The WEB/CP-700 unit base has a molded DIN rail slot and locking clip, as does the NPB-PWR-UN-H power supply module and any I/O expansion modules. Mounting on a DIN rail ensures accurate alignment of connectors between all modu

Summary of the content on the page No. 9

WEB-700 WEB-700-O CP-700 To mount on DIN rail 1. Securely install the DIN rail with at least two screws, near the two rail ends. 2. Position the NPB-PWR-UN-H power supply module on the rail, tilting to hook DIN rail tabs over one edge of the DIN rail (Fig. 3). 3. Use a screwdriver to pry down the plastic locking clip, and push down and in on the module, to force the locking clip to snap over the other edge of the DIN rail. 4. Mount the WEB/CP-700 controller onto the DIN rail in the same way, s

Summary of the content on the page No. 10

WEB-700 WEB-700-O CP-700 Board Layout Fig. 5 shows the location of connectors, option slots, and other features of the main board in the WEB/CP-700. For side views of communications ports and other features, see Fig. 6, page 13. Option card 2 area including socket header Serial mode select jumper NiMH battery connector (keyed) Earth grounding lug MiniPCI socket LED header PS - OUT PS - PS + OUT PS + DDR-2 BB 12V RAM RS-485 - RS-485 + 485 GND RS-485 support of remote IO modules LEDs LANn De

Summary of the content on the page No. 11

WEB-700 WEB-700-O CP-700 ABOUT EXPANSION OPTIONS The WEB/CP-700 provides for field-installable expansion using these types of options: • Option card — Install on connectors inside the WEB/CP-700 base unit. See About Option Cards, page 11. • Remote I/O modules — To wire to the WEB/CP-700’s right-side 6-pin connector. See About Remote I/O Modules, page 12. • MiniPCI option card — (future use). See About MiniPCI Cards, page 12. About Option Cards The WEB-700/CP has two (2) available option slots to

Summary of the content on the page No. 12

WEB-700 WEB-700-O CP-700 OPTION CARD COM PORT ASSIGNMENTS COM port assignments for option cards installed in a WEB/CP-700 start at COM5, with Slot 1 evaluated first, then Slot 2. (COM1 and COM2 are always assigned to the onboard RS-232 and RS-485 ports, while COM3 and COM4 are reserved for slots.) INSTALLING AN OPTION CARD For option-specific details, see the mounting & wiring document that accompanies the particular option card. The following procedure provides a basic set of steps. WARNING I

Summary of the content on the page No. 13

WEB-700 WEB-700-O CP-700 WIRING DETAILS See Fig. 5, page 10 to locate connectors and other components on the WEB/CP-700 controller. Make connections to the WEB/CP-700 in the following order. 1. Install any option board (LON, RS-485, RS-232, etc.) in the available option slots. See Installing an Option Card, page 12 for a procedure. For complete details, refer to the specific documentation that accompanied the option. 2. Connect communications cables. See Communications Wiring, page 13 for port

Summary of the content on the page No. 14

WEB-700 WEB-700-O CP-700 SERIAL There are two “RS” serial ports on the WEB/CP-700 base board. Each has a UART capable of operation up to 115,200 baud. At the bottom of the board (see Fig. 6, page 13) is an RS-232 port using an DB-9 plug (male) connector. On the right side of the unit is an isolated RS-485 port, using the bottom three terminals of a 6-position screw-terminal connector plug. NOTE: Additional serial ports may be added with option card(s) in Option Slot 1 and Slot 2, such as an NP

Summary of the content on the page No. 15

WEB-700 WEB-700-O CP-700 WEB/CP-700 NPB-PWR-UN-H Grounding lug (remove cover) Supplied earth grounding wire 20-pin connector not used L AC Input L N Line Grounding lug Neutral 120 or 240Vac 50–60 Hz Earth Ground Single Phase Fig. 7. Grounding and power wiring connections to NPB-PWR-UN-H module. Power Wiring There are two power options for the WEB/CP-700 controller: the NPB-PWR-UN-H power supply module (typical), or a NPB- WPM-US (Wall Mount AC Adapter). NPB-PWR-UN-H The NPB-PWR-UN-H module le

Summary of the content on the page No. 16

WEB-700 WEB-700-O CP-700 Wiring NPB-PWR-UN-H input power and earth ground. 1. Remove power from the AC circuit being wired to the NPB-PWR-UN-H—see previous . 2. Remove the NPB-PWR-UN-H cover. To do this, press in the four tabs on both ends of the unit, and lift the cover off. If the WEB/CP-700 is plugged into the unit, you may need to slide it away to get to the cover tabs. 3. Connect the supplied earth grounding wire to a nearby grounding point. See Fig. 7. 4. Make AC circuit connections lin

Summary of the content on the page No. 17

WEB-700 WEB-700-O CP-700 Contact Inputs Three contact inputs (CIs) are available on a 6-position connector next to the 2-position external battery connector. CIs are typically used to monitor normally-closed (N.C.) alarm contacts, if available on a UPS and/or the “door tamper” switch of an enclosure. These CIs are unsupervised—no end-of-line resistors are required. Fig. 9 shows example wiring to all three CIs of the WEB/CP-700. WEB/CP-700 UPS Alarm Contacts Tamper switch Power Fail (if avai

Summary of the content on the page No. 18

WEB-700 WEB-700-O CP-700 EXTERNAL 12V BACKUP BATTERY A 2-position connector provides support for an external 12V sealed lead-acid (SLA) type rechargable battery. For more details, see About the Backup Batteries, page 20. WEB/ CP-700 15Vdc power and backup battery passed through 6-position connector 712BNP 12V Sealed Lead Acid Backup Battery(ies) Fig. 10. Sealed lead-acid backup battery connection on WEB/CP-700. 2 2 NOTE: The minimum wire size for battery connections is 18AWG (1.0mm ) for

Summary of the content on the page No. 19

WEB-700 WEB-700-O CP-700 Wiring to Remote I/O Modules Wiring to remote I/O modules typically provides both 15Vdc power and 12V battery backup, along with RS-485 communications to the modules. See Fig. 11. Connect shield wire to ground at one end only WEB/CP-700 Power Supply (15V) and 12V Backup Battery is routed to remote IO modules using a 3-conductor with shield cable. Use the shortest wiring route possible for power wiring—star, tee, bus, and loop topologies are all permissible. IO-16-R

Summary of the content on the page No. 20

WEB-700 WEB-700-O CP-700 If after applying power, the STATUS LED goes out, or if the BEAT LED comes on (steady) and stays lit longer than 2 minutes, contact your local distributor for technical assistance. See also “About LEDs” on page 21. About the Backup Batteries A WEB/CP-700 controller has two different backup batteries: • An on-board NiMH battery pack, and • An optional external, sealed lead-acid, rechargeable backup battery (or batteries). See below. For continuous system operation durin


Alternative user manuals
# User manual Category Download
1 Honeywell 3800gHD3800gHD User manual Barcode Reader 36
2 Honeywell SUB Series Interval Data Recorders 62-0342-01 User manual Barcode Reader 3
3 Honeywell EGPWS User manual Barcode Reader 15
4 Honeywell 1900 EZ User manual Barcode Reader 44
5 Honeywell PRO-2200 User manual Barcode Reader 3
6 Honeywell 3800 User manual Barcode Reader 18
7 Honeywell NIAGARA WEB-700-O User manual Barcode Reader 5
8 Honeywell NIAGARA WEB-700 User manual Barcode Reader 42
9 Sony BRAVIA KDL-20S2020 User manual Barcode Reader 73
10 Sony BRAVIA KDL-20S2000 User manual Barcode Reader 35
11 Philips 3121 233 42852 User manual Barcode Reader 0
12 Philips GoGear SA2526 User manual Barcode Reader 0
13 Philips SA2540 User manual Barcode Reader 0
14 Philips SA2516 User manual Barcode Reader 0
15 Philips SA2520 User manual Barcode Reader 0