SUB Series Interval Data Recorders
INSTALLATION MANUAL
NOTE: IDRs with modular jacks can be powered from either
PRE-INSTALLATION
the first Honeywell meter or by an external power
supply (requires 120 VAC). IDRs with removable
INFORMATION
screw-type connectors require an external power
supply (provided).
The SUB Series Interval Data Recorder (IDR) is an energy
data collection device. Installation must be performed by
SUBIDR-16’s are supplied with an ID letter for each group of 8
qualified
Summary of the content on the page No. 2
SUB SERIES INTERVAL DATA RECORDERS 3. Modular Jacks & Screw-Type Connectors (SUBIDR-16 Connect this meter to jack #1 on the IDR using an 8- ONLY): Supplied with 8 modular jacks and 8 screw-type conductor flat modular cable. (See Chapter 5.0 if the connectors. Used with a mixture of Honeywell and third- IDR has the optional AC adapter.) party meters. (Requires external power supply.) 3. *All remaining Honeywell meters must be connected to the meter jacks #2-8 using 6-conductor flat modular cab
Summary of the content on the page No. 3
SUB SERIES INTERVAL DATA RECORDERS removed. The third-party meter IDR uses a DIP switch to — D7 (Low Battery) -> This LED must be OFF. This perform this function. This switch is preset at the factory and LED indicates a low or missing battery. requires no further adjustment. — D6 (System Error) -> This LED must be OFF. 3. Meter pulse indicators — Yellow LEDs P1 through P8 may be flashing. These LEDs indicate each meter’s pulse rate. The flash rate depends on how much load the meter is measur
Summary of the content on the page No. 4
SUB SERIES INTERVAL DATA RECORDERS IMPORTANT: METHOD 1: MODULAR PLUG METHOD The AC adapter is designed to be used with a 120 This method requires using 4 stranded conductors inside a VAC outlet only. cable that is fitted with an RJ-11 type plug for 4-conductor modular systems at each end of the cable. 5. The IDR should now be energized. Perform the visual * Do not use any pre-made telephone cables. See Appendix A checks outlined in section 4. for correct cable configuration. NOTE: The AC ad
Summary of the content on the page No. 5
SUB SERIES INTERVAL DATA RECORDERS Using the USB connection on your APPENDIX A - CABLE computer CONFIGURATION As an alternative to the SUB-RS232K converter, we offer the SUB-USBK that allows you to convert the RS485 output from A. Four-Conductor Cables (IDR RS-485 Communication) your IDRs for direct connect to your USB connection on your computer. Baud Rate Selection The communication baud rate is selected by means of a jumper on the circuit board (See appendix C for location.) There are
Summary of the content on the page No. 6
SUB SERIES INTERVAL DATA RECORDERS APPENDIX B - LED INDICATORS D7-Clear Red LED L1-Green LED Low Battery Serial Communications MUST be "OFF" Power Supply (Indicates low battery Always "ON" when lit) (Indicates power supply is okay if LED is ON) D4-Red LED D6-Clear Red LED CPU Status System Error Flashes once per Always "OFF" when second system is operating normally D1-Green LED D2-Yellow LED See "Serial Communications" L3-Green LED P1-P8-Yellow LED Main Power Indicator Meter Pulse Indicators Alw
Summary of the content on the page No. 7
SUB SERIES INTERVAL DATA RECORDERS APPENDIX C - IDR CIRCUIT BOARD COMPONENTS J3-J4-RS-485 Communications Jacks Battery CPU Reset Button See "Serial Communications" (Ports used to connect one IDR to another IDR or Key) Baud Rate Selection See "Serial Communications" (Selects communication baud rate ALWAYS set at 9600 BPS when modem is present) Baud Rate Selection M1-M8-Meter Inputs JMP-8-Meter Power Selection See Chapter 6 (Ports used to connect See “Main Circuit Board d"Communications" meters
Summary of the content on the page No. 8
SUB SERIES INTERVAL DATA RECORDERS APPENDIX D - SYSTEM WIRING GUIDES Wiring Guide for SUBIDR-8 DB-9 (DTE) Connector RJ-45 SUB-RS232K PC RJ-11 6' cable provided by Honeywell (15 ft max.) AC Adapter 8-conductor cable & modular plug 4-Conductor Flat Modular Cable Up to 4000 Feet Total Daisy-Chain or Star Connection Channel 1 of 3 (One of three channels shown for clarity.) (Up to 8 Meters) IDR A 6-Cond. 8-Cond. 6-Cond. RJ-45 RJ-45 RJ-45 RJ-11 (Up to 8 Meters) Up to 52 SUBIDR-8
Summary of the content on the page No. 9
SUB SERIES INTERVAL DATA RECORDERS Wiring Guide for SUBIDR-16 DB-9 (DTE) Connector RJ-45 SUB-RS232K PC RJ-11 6' cable provided by Honeywell (15 ft max.) AC Adapter 8-conductor cable & modular plug 4-Conductor Flat Modular Cable Up to 4000 Feet Total Daisy-Chain or Star Connection Channel 1 of 3 IDR A-B (One of three channels shown for clarity.) (Up to 16 Meters) 6-Cond. 8-Cond. 6-Cond. RJ-45 RJ-45 RJ-45 RJ-11 (Up to 16 Meters) IDR Y-Z Up to 26 SUBIDR-16s per channel ~ (3
Summary of the content on the page No. 10
SUB SERIES INTERVAL DATA RECORDERS APPENDIX E - HARDWIRED SYSTEM CONFIGURATION DIAGRAMS SUBIDR-8, Using Honeywell Meters: IDR Up to 8 Meters Up to 4000 Feet Total ~ Up to 52 ~ Channel 1 SUBIDR-8’s IDR Up to 8 Meters PC RS-232 Serial Port COM1 - COM4 15’ max SUB-RS232K* Channel 2 IDR AC Adapter Up to 8 Meters Channel 3 Up to 4000 Feet Total ~ Up to 52 ~ SUBIDR-8’s IDR Up to 8 Meters NOTE: Meter #1 must be installed within 100 feet of IDR. Meters #2-16 must be installed within 500 feet of IDR
Summary of the content on the page No. 11
SUB SERIES INTERVAL DATA RECORDERS SUBIDR-16, Using Hone ywellMeters IDR Up to 16 Meters Up to 4000 F eet T otal ~ Up to 26 ~ Channel 1 SUBIDR-16’s IDR Up to 16 Meters PC RS-232 Ser ial P or t COM1 - COM4 SUB-RS232K* Channel 2 6' cab le pro vided b y IDR Honeywell (15 ft max.) A C Adapter Up to 16 Meters Channel 3 Up to 4000 F eet T otal ~ Up to 26 ~ SUBIDR-16’s IDR Up to 16 Meters NO TE: Meter #1 m ust be installed within 100 f eet of IDR. Meter s #2-#16 m ust
Summary of the content on the page No. 12
SUB SERIES INTERVAL DATA RECORDERS APPENDIX G - IDR TECHNICAL SPECIFICATIONS Enclosure: Lockable steel JIC box NEMA 12. Dimensions: 9.5” H x 6.75” W x 3.875” D. Knockouts: Three (3) on bottom of enclosure (3/4” Cond.) Power Supply: Powered by meter or optional 120 VAC adapter. Back Up: Lithium Power Cell LTC-3PN (10 year lifetime) LED Indicators: Input pulse, CPU operation, alarm, power, communication Inputs SUBIDR-8: Eight (8) eight-pin modular ports or Eight (8) 2-screw plug-in terminals SUB
Summary of the content on the page No. 13
SUB SERIES INTERVAL DATA RECORDERS LIMITED WARRANTY Subject to the exclusions listed below, Honeywell will either accident or the negligence of any party; (iv) damaged as a repair or replace (at its option) any product that it result of events beyond Honeywell’s control or other force manufactures and which contains a defect in material or majeure events or (v) used in conjunction with equipment, workmanship. components, accessories, parts or materials not supplied or approved by Honeywell.
Summary of the content on the page No. 14
SUB SERIES INTERVAL DATA RECORDERS 62-0342—01 14
Summary of the content on the page No. 15
SUB SERIES INTERVAL DATA RECORDERS 15 62-0342—01
Summary of the content on the page No. 16
SUB SERIES INTERVAL DATA RECORDERS Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive ® U.S. Registered Trademark Toronto, Ontario M1V 4Z9 © 2011 Honeywell International Inc. 62-0342—01 M.S. 02-11 www.honeywell.com/buildingsolutions Printed in U.S.A.