Anaheim DPG1004-01 user manual

User manual for the device Anaheim DPG1004-01

Device: Anaheim DPG1004-01
Category: Impact Driver
Manufacturer: Anaheim
Size: 0.67 MB
Added : 5/15/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Anaheim DPG1004-01. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Anaheim DPG1004-01.

For your convenience

If looking through the Anaheim DPG1004-01 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Anaheim DPG1004-01 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Anaheim DPG1004-01 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Anaheim DPG1004-01 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Anaheim DPG1004-01 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Anaheim DPG1004-01. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DPG10002-01, DPG10003-01, DPG10004-01
Microstep Driver Pack
User’s Guide
ANAHEIM AUTOMATION
910 East Orangefair Lane, Anaheim, CA 92801 (714) 992-6990 fax: (714) 992-0471
e-mail: info@anaheimautomation.com website: www.anaheimautomation.com
#L010167 December 2004

Summary of the content on the page No. 2

DPG10002-01, DPG10003-01, DPG10004-01 Microstep Driver Pack Features • Integrated MBC10641, Power Supply, and Cooling Fan • 90-265 VAC Input • Output Current 10.0 Amps Peak • 200 to 12,800 steps/rev (1,2,5,8,10,16,32 and 64 selectable step operations) • Short Circuit Protection • Motor Miss-Wire Detection • No minimum Inductance • Optical Isolation • Motor ON/OFF Input Introduction The MBC10641 Microstep Driver has an output current capability of 1.5 Amps minimum to 10.0 Amps maximum (Peak Ratin

Summary of the content on the page No. 3

TB1: 8 Pin Terminal - All Connections INTERNALLY Wired to 25DB Port Pin # Description 1: Step Clock Input Anode (+) A positive going edge on this isolated input advances the motor one increment. The size of the increment is dependent on the Microstep Select Inputs of Switch 1. 2) Step Clock Input Cathode (- 3: Direction Anode (+) This isolated input is used to change the direction of the motor. Physical direction also depends on the connection of the motor windings. 4) Direction Cathode (- 5: ON

Summary of the content on the page No. 4

Absolute Maximum Ratings Input Voltage: 90-265 VAC Output Current: 10.0 AMPS PEAK Max Plate Temperature: 70° C Storage Temperature: 0° to +50° C Input Voltage (For isolated inputs): +5V to +24V at 2.5mA Electrical Specifications Item Min Typ Max Units Input Voltage 95 0 2C 6 VA Phase Output Current11 .0 7) . A (RMS Phase Output Current10 .5 1) 0. A (PEAK Clock Frequency 004z 0 kH Chopping Frequency 27 0 233z kH +5VDC 45 .8 5V .2 +5VDC 005A m Operation Temperature007C Hook Up Drawings Hook Up fo

Summary of the content on the page No. 5

DB25 PIN Port Connection Description 1. No Connection 14. Enable All Windings 2. No Connection 15. No Connection 3. No Connection 16. No Connection 4. No Connection 17. No Connection 5. No Connection 18. No Connection 6. No Connection 19. A Direction Input 7. No Connection 20. Z Direction Input 8 No Conneciton 21. Y Direction Input 9. X Direction 22. +5VDC Input Required to Power Driver OPTO 10. A Step ( Clock Input) 23. +5VDC Input Required to Power Driver OPTO 11. Z Step ( Clock Input) 24. No

Summary of the content on the page No. 6

Microstep Selection (SW1 Settings) Switches 2, 3 and 4, of the DIP switch select the number of microsteps per step. Table 7 shows the standard resolution values along with the associated positions for the select switches. The standard wave- forms are sinusoidal. Resolution Steps/Rev Select 1 Select 2 Select 3 Select 4 Auto Reduce Current 1 2F 00 ON F ONONOd Disable 2 4F 00 ON F ONOFOd F Disable 5 1F 000 ON F OFON FOd Disable 8 1F 600 ON F OFOF FOd F Disable 10 2F 000 OF F ON F ONOd Disable 16 3F

Summary of the content on the page No. 7

Step Motor Selection Guide Series Parallel Motor Current Unipolar Series Peak Parallel Peak Motor Example Current Current Number Code Rating Rating Rating Setting Setting 22 3D10S 02 1A .0A 1A .0 2- .0 -% -- 5 23 3L308 D-LW 03 1A .5A 1A .5 3% .0 0% 20 34 4N108 S-LW 04 2A .0A 2A .0 4% .0 5% 30 25 3L4008 D-LW 05 2A .5A 2A .5 5% .0 1% 0 40 36 4A10B 06 3A .0A 3A .0 6% .0 2% 0 50 37 4N208 S-LW 07 3A .5A 3A .5 7% .0 2% 5 60 38 4K108 S-LW 08 4A .0A 4A .0 8% .0 3% 0 70 49 2N20B S-C 09 4A .5A 4A .5 9% .0

Summary of the content on the page No. 8

Step Motor Configurations Step motors can be configured as 4, 6, or 8 leads. Each configuration requires different currents. Refer to the lead configurations and the procedures to determine their output current. WARNING! Step motors will run hot even when configured correctly. Damage may occur to the motor if a higher than specified current is used. Most specified motor currents are maximum values. Care should be taken to not exceed these ratings. 6 Lead Motors When configuring a 6 lead motor in

Summary of the content on the page No. 9

8 Lead Motors Series Connection: When configuring the motor windings in series, use the per Phase (or unipolar) current rating to determine the current setting potentiometer value. Parallel Connection: When configuring the motor windings in parallel, multiply the per Phase (or unipo- lar) current rating by 2.0 to determine the current setting potentiometer value. NOTE: After the current has been determined, according to the motor connections above, use Table 3 to choose the proper setting for th

Summary of the content on the page No. 10

Dimension Drawings DPG10002-01, DPG10003-01 and DPG10004-01 Micostep Driver Pack User’s Guide # L010167

Summary of the content on the page No. 11

COPYRIGHT Copyright 2001 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. DISCLAIMER Though every effort has been made to supply complete and accurate informatio

Summary of the content on the page No. 12

Torque Speed Curves ANAHEIM AUTOMATION User’s Guide # L010167


Alternative user manuals
# User manual Category Download
1 Anaheim DPG10003-01 User manual Impact Driver 1
2 Anaheim DPG10002-01 User manual Impact Driver 1
3 Sony MDS-NT1 User manual Impact Driver 39
4 AMD GA-7VASFS-FS User manual Impact Driver 41
5 Alpine VOLUME 1.3 User manual Impact Driver 3
6 Anaheim DPG10003-01 User manual Impact Driver 1
7 Anaheim DPG10002-01 User manual Impact Driver 1
8 ATD Tools atd-2102 User manual Impact Driver 0
9 ATD Tools ATD-2112 User manual Impact Driver 1
10 ATD Tools ATD-10521 User manual Impact Driver 0
11 ATD Tools ATD-112 User manual Impact Driver 1
12 ATD Tools ATD-2114 User manual Impact Driver 0
13 ATD Tools ATD-2150 User manual Impact Driver 0
14 ATD Tools ATD-2151 User manual Impact Driver 0
15 Bahco IZO-D User manual Impact Driver 74