Summary of the content on the page No. 1
Installation and
Quick Configuration
Manual
®
NetBotz Room
Monitor 455
NBWL0455
NBWL0456
Summary of the content on the page No. 2
This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Este manual está disponible en español en el CD-ROM adjunto. Ce manuel est disponible en français sur le CD-ROM ci-inclus. Questo manuale è disponibile in italiano nel CD-ROM allegato. 本マニュアルの日本語版は同梱の CD-ROM からご覧になれます。 Instrukcja obs ługi w j ęzyku polskim jest dost ępna na CD. O manual em Português está disponível no CD-ROM em anexo. Данное ру к о во дс тво на ру с с к
Summary of the content on the page No. 3
Contents Introduction 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Document Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Additional Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 InfraStruXure-certified . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Physica
Summary of the content on the page No. 4
The APC Configuration Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Access an Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Administrator account user ID and password . . . . . . . . . 20 Root account user ID and password . . . . . . . . . . . . . . . 20 Lost password recovery . . . . . . . . . . . . . . . . . . . . . . . . . 21 Basic View . . . . . . . . . . . .
Summary of the content on the page No. 5
Introduction Product Description ® ® The American Power Conversion (APC ) NetBotz Room Monitor 455 functions as the central hardware appliance for a NetBotz security and environmental monitoring system. The NetBotz 455 can be installed anywhere in a room and includes an integrated camera and internal sensors that monitor temperature, humidity, air flow, and motion. It also includes four sensor ports for connecting temperature, humidity, smoke, door, vibration, spot fluid, and third-party d
Summary of the content on the page No. 6
Attention: THE EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, VISUAL RECORDING CAPABILITIES, THE IMPROPER USE OF WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY REQUIRE AMONG OTHER THINGS EXPRESS WRITTEN CONSENT FROM RECORDED SUBJECTS. YOU ARE SOLELY RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR STRICT ADHERENCE TO ANY/ALL RIGHTS OF PRIVACY AND PERSONALTY. USE OF THI
Summary of the content on the page No. 7
Additional Options The following options are available for the NetBotz 455. For more information about any of the options, contact your APC representative or the distributor from whom you purchased your APC product. • NetBotz Camera Pod 160 (NBPD0160) • NetBotz Rack Sensor Pod 150 (NBPD0150) • NetBotz Room Sensor Pod 155 (NBPD0155) • Temperature Sensor (AP9335T) • Temperature/Humidity Sensor (AP9335TH) • Temperature Sensor with Digital Display (AP9520T) • Temperature/Humidity Sensor wit
Summary of the content on the page No. 8
Physical Description Front Item Description Vented internal Vented opening for airflow, temperature, and humidity sensors. sensors Network link LED Shows the status of the network connection. Blinks to indicate network traffic (green—connected at 10 Mbps; yellow—connected at 100 Mbps). Power LED Indicates whether the unit is receiving power (green—receiving power; dark—not receiving power). Camera LED Blinks steadily when the integrated camera is active. Alert LED Indicates the alert s
Summary of the content on the page No. 9
Rear Item Description Microphone jack Supports audio sensing, audio recording, and two-way audio. Maximum length of microphone cable: 3 m (9.8 ft). Speaker jack Supports two-way audio. Maximum length of speaker cable: 3 m (9.8 ft). A-Link port Used for cascading NetBotz sensor pods and temperature and humidity sensors with digital displays. Provides communications and power to the connected devices over standard CAT-5 cabling with straight-through wiring. For details, see “Connect Senso
Summary of the content on the page No. 10
Inventory Inspect the contents of the package to ensure that the parts included match those shown below. Report missing or damaged contents to APC or your APC reseller. However, if damage was due to shipping, immediately report the damage to the shipping agent. The shipping and packaging materials are recyclable. Please save them for later use or dispose of them appropriately. 6 NetBotz 455 Installation and Quick Configuration Manual
Summary of the content on the page No. 11
Item Description NetBotz Room Monitor 455 Bracket mounting plate for electrical boxes Extender arms Ball-joint adjuster arms T-bar mounting plate Rubber bracket cover Mounting plate Cable retainer Mounting screw wall anchors Extender arm set screw 203-mm (8-in) tie wraps Adhesive cable tie holders 13-mm (0.5-in) machine screws (for electrical box) 19-mm (0.75-in) sheet metal screws (for wall or enclosure) 1.8 m (6-ft) NEMA 5-15P to IEC-320-C13 power cord (only inc
Summary of the content on the page No. 12
Installation Install the NetBotz 455 Choose an installation option that meets your needs. Take the following into consideration: Caution: Only connect approved devices to ports on the NetBotz 455 as directed in this manual. Plugging in other devices may result in equipment damage. Note: Consider the location of the nearest network port. Note: Make sure the camera will not be obstructed. Note: Consider cable routing for all sensors that you plan to connect to the appliance. Note: If the direc
Summary of the content on the page No. 13
Wall Note: Drill 4.76-mm (3/16-in) pilot holes for wall anchors. Caution: Do not overtighten the screws. NetBotz 455 Installation and Quick Configuration Manual 9
Summary of the content on the page No. 14
Ceiling 10 NetBotz 455 Installation and Quick Configuration Manual
Summary of the content on the page No. 15
Enclosure Note: Use a #32 drill to make four 2.94-mm (0.116-in) pilot holes. NetBotz 455 Installation and Quick Configuration Manual 11
Summary of the content on the page No. 16
Connect the NetBotz 455 to Your Network Power-over-Ethernet (PoE) injector Caution: Before you energize the NetBotz 455, review the electrical specifications on page 31 to avoid overloading the circuit. Caution: Be sure the appliance is properly grounded by plugging the power cord directly into a wall outlet or by verifying the ground path if you are using a power strip. Non-PoE-capable hub or switch PoE-capable hub or switch To appliance 10/100 Base-T network port 12 NetBotz 455 Installation
Summary of the content on the page No. 17
Connect Sensors to Sensor Ports This procedure applies to the following sensors, which are supported by the NetBotz 455 and connect to the sensor ports: • Temperature Sensor (AP9335T) • Temperature/Humidity Sensor (AP9335TH) • NetBotz Vibration Sensor (NBES0306) • NetBotz Smoke Sensor (NBES0307) • NetBotz Spot Fluid Sensor (NBES0301) • NetBotz 0-5 V Sensor Cable (NBES0305) • NetBotz Door Switch Sensor for APC Racks (NBES0303) • NetBotz Door Switch Sensor for Rooms or Third Party Racks
Summary of the content on the page No. 18
Connect Sensors and Sensor Pods to A-Link Ports You can cascade up to a combined total of two NetBotz Rack Sensor Pod 150s (NBPD0150) and NetBotz Room Sensor Pod 155s (NBPD0155) and up to a combined total of eight Temperature Sensors with Digital Display (AP9520T) and Temperature/Humidity Sensors with Digital Display (AP9520TH). You cannot cascade appliances. Use one appliance per system. A-Link is an APC proprietary CAN (Controller Area Network) bus. Devices compatible with A-Link are not
Summary of the content on the page No. 19
Adjust the Lens View the camera feed during the adjustment of the camera in lens housing order to correctly adjust the focus of the feed and field of view settings. To access the adjustment screws, remove the lens lock housing by turning the lens unlock housing counter-clockwise until the latches disengage. aperture To reattach the lens housing, engage the latches and rotate the housing clockwise until a click is heard. To adjust the aperture of the lens, rotate the aperture ring c
Summary of the content on the page No. 20
Initial Configuration Note: Disregard the procedures in this section if you have APC InfraStruXure Central as part of your system. See the documentation for your InfraStruXure device for more information. Overview You must configure the following TCP/IP settings before the appliance can operate on a network: • IP address of the appliance • Subnet mask • Default gateway Note: If a default gateway is unavailable, use the IP address of a computer that is located on the same subnet as the ap