Honeywell 11280S user manual

User manual for the device Honeywell 11280S

Device: Honeywell 11280S
Category: Automobile Parts
Manufacturer: Honeywell
Size: 0.62 MB
Added : 5/21/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell 11280S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell 11280S.

For your convenience

If looking through the Honeywell 11280S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell 11280S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell 11280S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell 11280S User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell 11280S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell 11280S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



61-86-03-13
Herculine 11280S
9/01
Page 1 of 14
Smart Actuator

Specification

Overview

Honeywell’s HercuLine 11280S Smart
actuators incorporate all of the high
quality and reliable features of the

traditional HercuLine actuators plus
the added benefits of a microprocessor-
based Enhanced Electronics Unit (EEU).
These additional benefits provide:
• Faster set-up and commissioning
• Network capability
• Health parameter monitoring for
proactive maintenance planning.
He

Summary of the content on the page No. 2

61-86-03-13 Page 2 Features (continued) Health Monitoring A standard feature on all 11280S Operation  actuators accumulates information • Factory Calibration – Factory • Control Signals – 0/4 to 20 mA, about actuator operation. This 0/1 to 5 Vdc, 0 to 10 Vdc, Digital calibration is stored in non-volatile information then can be used to remote setpoint (RS485 Modbus memory and can be restored via evaluate and determine predicted or the local HMI at any time. RTU protocol).

Summary of the content on the page No. 3

61-86-03-13 Page 3 Local Display and Keypad Configuration and set-up is through the local HMI, consisting of a display and keypad interface (Figure 2). A high intensity 10-character LED display and simple pushbuttons provide quick access for actuator set up and status information. If relay outputs are specified, all configuration can be done through either the local HMI interface. If mechanical switches are specified, then the user must manually set the auxiliary output. Control

Summary of the content on the page No. 4

61-86-03-13 Page 4 Set Up/Configuration Parameters Configuration parameters are logically grouped and accessed using the local HMI. Actuator calibration is also accomplished through a simple procedure using the keypad. By pressing the SETUP button on the HMI, you can step through the set up groups that contain all of the configuration parameters. The table below summarizes the configuration parameters available within the various set up groups. Full details of all configuration para

Summary of the content on the page No. 5

61-86-03-13 Page 5 Set Up Group Configuration Parameter Selections/Settings LOCKID – Set Security Password SET LOCK Enables lock out or access to selected LOCK – Lock Out set up group parameters and calibration values. FAILSF – Failsafe CFGTST – Configuration Test Diagnostic READ STATUS Displays failsafe condition RAMTST – RAM Test Diagnostic CALTST – Calibration Test Diagnostic and the results of various SEETST – Serial EEPROM Test diagnostics performed Diagnostic durin

Summary of the content on the page No. 6

61-86-03-13 Page 6 Specifications – General, Continued Physical Torque Output Shaft Key Output Maximum Handwheel Approx. Model # lb-ft (N_M) Shaft Size Size Shaft Overhang Diameter Maximum Length Load Weight 11284S 425 2" 1/2" 5" 3700 lb. 18" 300 lb. (576) (51 mm) (13 mm) (127 mm) (1678 kg) (457 mm) (136 kg) 11285S 840 2" 1/2" 5" 3700 lb. 18" 300 lb. (1139) (51 mm) (13 mm) (127 mm) (1678 kg) (457 mm) (136 kg) 11286S 1500 2" 1/2" 5" 3700 lb. 18" 300 lb. (2033) (51 mm) (13 mm) (127

Summary of the content on the page No. 7

61-86-03-13 Page 7 Specifications – Actuator Electrical Input Signals Analog: 0/4 to 20 mA (With supplied 250 ohm shunt resistor for current range) 0/1 to 5 Vdc 0 to 10 Vdc Digital: Remote Setpoint via Modbus RTU (RS485) Input Impedance Input Input Impedance 0/4 to 20 mA 250 ohms 0/1 to 5 Vdc 10 K ohms Provides characterization of the input signal. Input Characterization Selections are: Linear, Square Root or Custom. Sensitivity 0.2 % to 5 % of 90° span, proportion

Summary of the content on the page No. 8

61-86-03-13 Page 8 Pipe Linkage Kit Pipe linkage kits are available from Honeywell and can be used for linkage lengths from 24 to 240 inches (61 to 610 cm). The kits include the mechanical pipe couplings, load rod end (left-hand thread), connecting rods and locking nuts. See Figure 4. The actuator rod end (right-hand thread), nut and bolt are supplied with the actuator. The customer must supply a piece of schedule 40 pipe 2 ½” * (both ends with right-hand NP threads) and a nut and

Summary of the content on the page No. 9

61-86-03-13 Page 9 External Transformers 120 Vac (Single Phase) For customer applications requiring 120/240 Vac single phase operation, a step-up transformer is mounted in a separate enclosure (Model Selection Guide Table I, option 1). Figure 6 shows the installation for the transformer enclosure. 575 Vac (3 Phase) For customer applications requiring 575/460 Vac 3 phase operation, a step-down transformer is mounted in a separate enclosure (Model Selection Guide Table I, option 6). Fig

Summary of the content on the page No. 10

61-86-03-13 Page 10 Model Selection Guide Reference 62-86-16-19 Instructions Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Tables I thru VIII using the column below the arrow. A dot ( ) denotes unrestricted availability. Key Number I II III IV V VI VII VIII IX _ _ _ _ _ _ _ - _ - _---- _ _ _ _ _ _ _ _ _ - _ - _ _ _ _ _ _ - _ _ KEY NUMBER - Electronics Selection Availability Output Torque (lb. - ft.) (N - M) 4

Summary of the content on the page No. 11

61-86-03-13 Page 11 Model Selection Guide, continued 01128_ _ 4S 5S 6S 8S TABLE V - SWITCH AND RELAY OUTPUTS (2 mech end-of-travel limits standard) Selection 9S 7S Auxiliary Switches None 00 _ and 2 Aux. SPDT Switches 20 _ 2 Aux. + 2 Programmable Relay Outputs 22 _ 2 Programmable Relay Outputs 02 _ 4 Programmable Relay Outputs 04 _ Auto/Manual Switch None _ _0 One Auto/Manual Switch with Out-of-Auto Contact _ _1 TABLE VI - CONFIGURATION INTERFACE RemoteNone 0 Local Integrally mounted

Summary of the content on the page No. 12

61-86-03-13 Page 12 Figure 7 Mounting and Outline Dimensions for 11284S, 11285S, 11286S, 11288S, and 11289S Weather-Proofed Motor Actuators - Right Hand Floor Mounting, Handwheel Shaft Horizontal (D-MTG-616-200)

Summary of the content on the page No. 13

61-86-03-13 Page 13 Figure 8 Mounting and Outline Dimensions for 11284S, 11285S, 11286S, 11288S, and 11289S Weather-Proofed Motor Actuators - Left Hand Floor Mounting, Handwheel Shaft Horizontal (D-MTG-616-210)

Summary of the content on the page No. 14

61-86-03-13 Page 14 Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantabilit


Alternative user manuals
# User manual Category Download
1 Honeywell ML6425 User manual Automobile Parts 6
2 Honeywell 500 User manual Automobile Parts 22
3 Honeywell EXCEL 10 W7751H User manual Automobile Parts 99
4 Honeywell HERCULINE 2000 User manual Automobile Parts 59
5 Honeywell ALF502L User manual Automobile Parts 2
6 Honeywell ALF502R User manual Automobile Parts 2
7 Honeywell V4055F User manual Automobile Parts 0
8 Honeywell LF507 User manual Automobile Parts 0
9 Honeywell 2000 User manual Automobile Parts 1
10 Honeywell M7410F User manual Automobile Parts 3
11 Honeywell M6410A User manual Automobile Parts 5
12 Honeywell C7150B User manual Automobile Parts 1
13 Honeywell V4055G User manual Automobile Parts 0
14 Honeywell ML7425 User manual Automobile Parts 4
15 Honeywell M8405 User manual Automobile Parts 10
16 Sony BP-GL95 User manual Automobile Parts 25
17 Sony BP-GL65 User manual Automobile Parts 2
18 Philips Epic 50PF9966 User manual Automobile Parts 3
19 Philips HTS3011 User manual Automobile Parts 2
20 Philips SDJ6040W User manual Automobile Parts 1