Teledyne 730 Bubbler user manual

User manual for the device Teledyne 730 Bubbler

Device: Teledyne 730 Bubbler
Category: Automobile Parts
Manufacturer: Teledyne
Size: 1.14 MB
Added : 5/21/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 730 Bubbler. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 730 Bubbler.

For your convenience

If looking through the Teledyne 730 Bubbler user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 730 Bubbler on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 730 Bubbler to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 730 Bubbler User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 730 Bubbler but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 730 Bubbler. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

730 Bubbler Module
Installation and Operation Guide
Part #60-9003-063
Copyright © 1995. All rights reserved, Teledyne Isco, Inc.
Revision K, May 9, 2007

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Foreword This instruction manual is designed to help you gain a thorough understanding of the operation of the equipment. Teledyne Isco recommends that you read this manual completely before placing the equipment in service. Although Teledyne Isco designs reliability into all equipment, there is always the possi- bility of a malfunction. This manual may help in diagnosing and repairing the malfunc- tion. If the problem persists, call or e-mail the Teledyne Isco Technical Service Department for a

Summary of the content on the page No. 4

Summary of the content on the page No. 5

730 BubblerModule Safety 730 BubblerModule Safety General Warnings Before installing, operating, or maintaining this equipment, it is imperative that all hazards and preventive measures are fully understood. While specific hazards may vary according to location and application, take heed in the following general warnings: WARNING This instrument has not been certified for use in “hazardous locations” as defined by the National Electrical Code. WARNING Avoid hazardous practices! If you use thi

Summary of the content on the page No. 6

730 BubblerModule Safety DANGER DANGER – limited to the most extreme situations to identify an imminent hazard, which if not avoided, will result in death or serious injury. Hazard Symbols The equipment and this manual use symbols used to warn of hazards. The symbols are explained below. Hazard Symbols Warnings and Cautions The exclamation point within the triangle is a warning sign alerting you of important instructions in the instrument’s technical reference manual. The lightning flash and

Summary of the content on the page No. 7

730 Bubbler Module Table of Contents Section 1 Introduction 1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 Connecting to the Sampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.3 Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.4 Calibrating the Bubbler Module. . . . . . . . . . . . .

Summary of the content on the page No. 8

730 Bubbler Module Table of Contents Appendix B Technical Specifications Appendix C Material Safety Data Sheets List of Figures 1-1 730 Module Mounted on Sampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 2-1 Sample Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2-2 Sampler Programming: 730 Module Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-3 Sampler Programmin

Summary of the content on the page No. 9

730 Bubbler Module Section 1 Introduction 1.1 Introduction The 730 Bubbler Module is one of Teledyne Isco’s inter- changeable modules for the Avalanche and 6700 Series Sam- plers. The module uses a differential pressure transducer and a flow of bubbles to measure liquid levels up to ten feet. The bubbler is unaffected by wind, fluctuations in air or liquid tem- peratures, turbulence, steam, foam on the surface, corrosive chemicals, debris, oil, floating grease, or lightning. You can install the

Summary of the content on the page No. 10

730 Bubbler Module Section 1 Introduction 1.2 Connecting to the To install the module: Sampler 1. Turn the sampler off. 2. Remove the connector cap in the module bay and move it aside. 3. Slide the module into the bay. 4. Push against the module to be sure the connector is fully seated. To remove the module: 1. Turn the sampler off. 2. Press the silver button on top of the module and pull the module from the bay. 3. Replace the connector cap in the module bay. 1.3 Installation Checklist 1.

Summary of the content on the page No. 11

730 Bubbler Module Section 1 Introduction 1.6 General Mounting This section contains some general information regarding the installation of the 730 module. More detailed installation infor- Considerations for the mation can be found in Section 3 Installation Methods. Bubbler 1 1.6.1 Line Length A standard 25 foot (7.6 m) length of /8" (0.32 cm) ID vinyl line is shipped with the module. We recommend that you do not use lengths longer than 25 feet. Please consult with the factory if your installa

Summary of the content on the page No. 12

730 Bubbler Module Section 1 Introduction 1.6.4 Bubble Line For some applications, a stainless steel tube may be easier to Extensions install in the flow stream than the plastic bubble line because of its relative rigidity. The vinyl bubble line attaches by simply slipping the vinyl tube over the end of the extension. Contact your Teledyne Isco representative about purchasing a stainless steel bubble line extension. A copper extension to the bubble line is advantageous in applica- tions where al

Summary of the content on the page No. 13

730 Bubbler Module Section 2 Programming the Module 2.1 Module Screens When the controller is configured with the module, it adds the necessary screens for programming. The screens appear on the following pages in Figures 2-2 through 2-4. These figures outline the steps for module programming and calibration. For 6712 pro- gramming and general programming information refer to the sampler manual. 2.2 Programmed Enable When the 730 Module is installed, additional sampler enable options are availab

Summary of the content on the page No. 14

730 Bubbler Module Section 2 Programming the Module Summary Report Settings Report Flow Summary - 13 SEP-03 (FR) SAMPLER ID# 11343009 15:25 13-SEP-03 *********** PROGRAM SETTINGS *********** Flow at "FACTORY " Site ---------- On 13-SEP-03 SITE DESCRIPTION: "FACTORY " ---------- BUBBLER MODULE: 638324458 UNITS SELECTED: Day's Flow: 0.678964 Mg

Summary of the content on the page No. 15

730 Bubbler Module Section 2 Programming the Module MODULE INSERTED-- This screen appears only when a module has been DOWNLOAD DATA NOW changed or if the module was unplugged while OR LOSE ALL DATA! the sampler was powered. If NO is selected, DONE the sampler responds as if there is no module. Standard Extended 6712 SAMPLER 6712 SAMPLER STANDARD PROGRAMMING EXTENDED PROGRAMMING FOR HELP AT ANY FOR HELP AT ANY SCREEN PRESS ? KEY SCREEN PRESS ? KEY RUN RUN "EXTENDED 1' PROGRAM PROGRAM VIEW REPO

Summary of the content on the page No. 16

730 Bubbler Module Section 2 Programming the Module Module Setup V-NOTCH V-NOTCH WEIR ANGLE: RECTANGULAR 120 90 60 CIPOLLETTI 45 30 22.5 MODE OF OPERATION: FLOWMETER LEVEL ONLY END CONTRACTIONS ON RECTANGULAR WEIR? YES NO Weir WEIR FLUME DATA POINTS EQUATION MANNING FLOW-INSERT ENTER CREST LENGTH: _.__ ft (min, max) Flume PALMER-BOWLUS PALMER-BOWLUS SIZE: PARSHALL 4" 6" 8" 10" TRAPEZOIDAL 12" 15" 18" 21" H 24" 27" 30" 48" EDIT DATA POINTS CLEAR DATA SET SELECT NEW SET

Summary of the content on the page No. 17

730 Bubbler Module Section 2 Programming the Module This screen appears only when a module has been MODULE INSERTED-- changed or if the module was unplugged while DOWNLOAD DATA NOW the sampler was powered. If NO is selected, OR LOSE ALL DATA! the sampler responds as if there is no module. DONE Standard Extended 6712 SAMPLER 6712 SAMPLER Note: STANDARD PROGRAMMING EXTENDED PROGRAMMING FOR HELP AT ANY FOR HELP AT ANY To program the module or SCREEN PRESS ? KEY SCREEN PRESS ? KEY run a program t

Summary of the content on the page No. 18

730 Bubbler Module Section 2 Programming the Module 2.4 Operation of the When measuring flow rate, the module is used with a primary measuring device (typically a weir or a flume) or other open Bubbler System channel flow arrangement where a known relationship exists between level and flow rate (refer to Table 2-1 Flow Conversion Types). The level measuring device is a bubbler which measures the liquid level in the flow stream. The level reading is converted into a properly scaled flow rate valu

Summary of the content on the page No. 19

730 Bubbler Module Section 2 Programming the Module The following table contains programming information for each of the conversion types. Table 2-1 Flow Conversion Types Conversion Type Device, Formula, or Table Size or Parameters Weir V- Notch Weir 22.5, 30, 45, 60, 90, 120 degrees Rectangular Weir with End Crest length Contractions Rectangular Weir without End Crest length Contractions Cipoletti Weir Crest length Flume Palmer-Bowlus Flume 4, 6, 8, 10, 12, 15, 18, 21, 24, 27, 30, 48 inches Par

Summary of the content on the page No. 20

730 Bubbler Module Section 2 Programming the Module 2-8


Alternative user manuals
# User manual Category Download
1 Teledyne HASTINGS 200 User manual Automobile Parts 3
2 Teledyne 203 User manual Automobile Parts 0
3 Teledyne 201 User manual Automobile Parts 1
4 Teledyne 202 User manual Automobile Parts 0
5 Teledyne 200 User manual Automobile Parts 0
6 Teledyne 207 User manual Automobile Parts 0
7 Teledyne HFC-302 User manual Automobile Parts 0
8 Teledyne HFC-303/307 User manual Automobile Parts 0
9 Teledyne 205 User manual Automobile Parts 0
10 Teledyne HFM-I-401 User manual Automobile Parts 0
11 Teledyne HFM-300 User manual Automobile Parts 1
12 Teledyne HFM-I-405 User manual Automobile Parts 1
13 Sony BP-GL95 User manual Automobile Parts 25
14 Sony BP-GL65 User manual Automobile Parts 2
15 Philips Epic 50PF9966 User manual Automobile Parts 3
16 Philips HTS3011 User manual Automobile Parts 2
17 Philips SDJ6040W User manual Automobile Parts 1