Summary of the content on the page No. 1
550
System Controller WV-CU CJ
AF
IRIS
RESET CLOSE OPEN
1
2 3
4
5 6
7
8 9
ZOOM
FOCUS
TELE
NEAR
MON CAM
0
SLOW
WIDE
FAR
ESC
SET
ALARM
BUSY
F1 F2
F3
F4
ACK
BACK FORWARD
RESET
SEQ SEQ ALT
AUX
DEC INC
1 2 -1CAM +1CAM STOP
System Controller
Operating Instructions
Model No. WV-CU550CJ
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
FRANÇAIS ENGLISH
Summary of the content on the page No. 2
ENGLISH VERSION CONTENTS IMPORTANT SAFETY INSTRUCTIONS ........................................................................................................................................ 3 PREFACE ...................................................................................................................................................................................... 4 FEATURES ........................................................................................................
Summary of the content on the page No. 3
IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarize
Summary of the content on the page No. 4
PREFACE The WV-CU550CJ System Controller, when combined with the optional WJ-SX550C Matrix Switcher and WJ-AD550 Extension Unit, allows for flexible control of 128 cameras and 16 monitors. When used in a system with either Receivers (WV-RC100 or WV-RC150) or with Panasonic’s Combination cameras, the WV- CU550CJ can control camera functions such as zoom and focus and can also control accessory equipment such as Pan/Tilt Heads. In addition, the WV-CU550CJ can control sequential switching in system
Summary of the content on the page No. 5
PRECAUTIONS • Refer all work related to the installation of this •Do not use strong or abrasive detergents when product to qualified service personnel or system cleaning the appliance body. installers. Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent • Do not attempt to disassemble the appliance. and wipe gently. To prevent electric shock, do not remove screws or covers. • Do not operate the appliance beyond its specified There are no
Summary of the content on the page No. 6
4 3 2 1 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ■ Front View q w e r t ALARM BUSY y u F1 F2 F3 F4 @0 @1 ACK BACK FORWARD IRIS ALT 1 2 3 RESET SEQ SEQ PRESET CLOSE OPEN @3 4 5 6 AF @2 7 8 9 AUX DEC INC ZOOM FOCUS 1 2 -1CAM +1CAM STOP TELE NEAR MON 0 CAM WIDE FAR SLOW ESC SET System Controller WV-CU CJ 550 !9 !8 !7 !6 !5 !4 !3 !2 !1 !0 o i ■ Rear View DATA CONTROLLER CONTROLLER IN OUT UNIT No. MODE 1-8 TERM. 0 ON OFF ON OFF @4 @5 @6 @7 @8 @9 6 9 8 7 6 5
Summary of the content on the page No. 7
q Alarm Indicator (ALARM) !2 Preset Button (PRESET) Blinks to indicate that an alarm condition exists. Auto Focus Button (AF) It changes to steady light when the alarm is reset auto- PRESET: This button, in combination with the Numeric matically. keys, is used to move the selected camera to a pre- To turn the indicator off, press the ACK RESET button. set position in a system equipped with the specified cameras. w Busy Indicator (BUSY) Lights up when you attempt to control a monitor or a AF: Pre
Summary of the content on the page No. 8
!8 Decrement Button (DEC –1CAM) @7 Mode Selection Switch (MODE) When a sequence running in forward direction has These switches are used to set the mode of the System been paused with the STOP button, pressing this button Controller connected to the Matrix Switcher. Set the will move the sequence one frame to the previous step switches as shown below. (in forward run direction). If the sequence was running in reverse direction, the button will move the sequence MODE one frame to the previous ste
Summary of the content on the page No. 9
System Controller WV-CU CJ 550 AF IRIS RESET CLOSE OPEN 1 2 3 4 5 6 7 8 9 ZOOM FOCUS TELE NEAR MON CAM 0 SLOW WIDE FAR ESC SET ALARM BUSY F1 F2 F3 F4 ACK BACK FORWARD RESET SEQ SEQ ALT AUX DEC INC 1 2 -1CAM +1CAM STOP INSTALLATION ■ System Controller for the WJ-FS616 Series Video Multiplexer When combined this System Controller with the optional WJ-FS616 Series Video Multiplexer, place the display sheets and label on the controller shown below. Refer to the Operat
Summary of the content on the page No. 10
SYSTEM INFORMATION Please note that the following functions were added to ■ Version Information improve the operation of the combination cameras. ● WJ-SX550 Series Matrix Switcher The onscreen display indicates the version in “Cold Start” or “Normal Start” during the power up procedure. ■ Additions ● Selection of Pan/Tilt Speed Matrix Switcher The Pan/Tilt speed can be changed by selecting a mode in Model WJ-SX550C the menu (A1) displayed on the LCD display of the con- "Normal Start" troller. CP
Summary of the content on the page No. 11
SPECIFICATIONS Power Supply: 120 V, AC 60 Hz Power Consumption: Approx. 4 W Data Input/Output: 6-conductor Modular Jack (RS-485, 4-wire) Switching Functions: Program Sequence/Tour Sequence Group Sequence/Backward Sequence Forward Sequence/Inc Dec Camera Functions: Electronic Shutter: On/Off, Shutter Speed Select Electronic Sensitivity Up Mode Select: Auto/Manual/Off Electronic Zoom: On/Off, Zoom Position: Area Select Back Light Compensation: Auto/Preset/Off Lens Functions: Iris: Open/Close/Prese
Summary of the content on the page No. 12
Panasonic Security and Digital Imaging Company Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, A Division of Matsushita Electric Corporation of America Ontario, L4W 2T3 Canada (905)624-5010 Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Panasonic Sales Company Regional Offices: Division of Matsushita Electric of Puerto Rico Inc. Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Ave. 65 de Infanteria. Km. 9.5 Southern: 1225 Northbrook Parkway, Suite 1-160