Summary of the content on the page No. 1
INST ALLA TION
Spectra IV IP Series
SD4E Dome System
In-Ceiling
Heavy-Duty In-Ceiling
Pendant (shown)
C3468M (4/10)
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Contents Important Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Legal Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Regulatory Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Open Source Software Notice . .
Summary of the content on the page No. 4
List of Illustrations 1 Preparing the Ceiling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Attaching the Conduit Fitting, Lock Nut, and Safety Chain Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3 Marking the Screw Hole Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4 Installing the Plates . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 5
List of Tables A Video Coaxial Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 B 24 VAC/24 VDC Wiring Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 C Troubleshooting the Spectra IV IP Dome System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 D Switch Settings for SW2 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 6
Important Notices LEGAL NOTICE SOME PELCO EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, AUDIO/VISUAL AND RECORDING CAPABILITIES, THE IMPROPER USE OF WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY REQUIRE, AMONG OTHER THINGS, EXPRESS WRITTEN CONSENT FROM RECORDED SUBJECTS. YOU ARE SOLELY RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR STRICT ADHERENCE TO ANY/ALL RIGHTS OF PRIVA
Summary of the content on the page No. 7
Description ® Spectra IV IP was designed with ease of installation and ease of maintenance in mind. Each dome system consists of three components: a back box, a dome drive, and a lower dome. Spectra IV IP back box options include the following models: environmental in-ceiling (ideal for outdoor soffits), indoor in-ceiling, standard and environmental pendant, heavy-duty, and stainless steel. Depending on the dome drive model with which it will be used, a back box can be ordered with or withou
Summary of the content on the page No. 8
Mounting IN-CEILING 1. Prepare the ceiling (refer to Figure 1): a. Locate the center point of the mounting location, and insert the compass tool into the ceiling. b. Place the end of a pencil in the hole on the end of the compass tool, and draw a circle. c. Cut out the circle. Figure 1. Preparing the Ceiling 2. Attach a conduit fitting (not supplied), lock nut (not supplied), and safety chain bracket (refer to Figure 2). 3. Install a safety chain/cable (not supplied), which will support up to
Summary of the content on the page No. 9
4. Open the hinged door to the back box by pushing the tab lock toward the wall of the unit and lifting the door open. 5. Pull the wiring into the back box through the conduit fitting. 6. Connect all required wiring (refer to Wiring on page 12). 7. Install the back box by compressing the spring clips and pushing the back box through the hole. 8. Tighten the screws until you hear a clicking noise. HEAVY-DUTY IN-CEILING 1. Prepare the ceiling (refer to Figure 1 on page 8): a. Locate the center po
Summary of the content on the page No. 10
Figure 4. Installing the Plates ì Back Mounting Plates î Ceiling ï Mounting Ring 5. Attach a conduit fitting (not supplied), lock nut (not supplied), and safety chain bracket (refer to Figure 2 on page 8). 6. Install a safety chain/cable (not supplied), which will support up to 16 pounds (7.3 kg). 7. Open the hinged door to the back box by pushing the tab lock toward the wall of the unit and lifting the door open. 8. Pull the wiring into the back box through the conduit fitting. 9. Connect all
Summary of the content on the page No. 11
PENDANT, HEAVY-DUTY PENDANT, AND STAINLESS STEEL 1. Install the mount for the pendant dome. Refer to the instructions supplied with the mount. NOTE: If the mount is outdoors, make sure it is properly sealed to keep moisture out. 2. Open the hinged door to the back box by pushing the tab lock towards the wall of the unit and lifting the door open. 3. Pull the wiring into the back box. 4. Connect all required wiring (refer to Wiring on page 12). 5. Screw the back box onto the mount (refer to Figu
Summary of the content on the page No. 12
Wiring 1. Open the hinged door to the back box by pushing the tab lock toward the wall of the unit and lifting the door open (refer to Figure 7). Figure 7. Back Box Door 12 C3468M (4/10)
Summary of the content on the page No. 13
2. Remove the TXB-N from the back box circuit board (refer to Figure 8): a. Loosen the captive screw on the TXB-N. b. Carefully unplug the TXB-N from the back box circuit board. + - Figure 8. Removing the TXB-N ì s RJ-45 Connector Standoff î t Ethernet Cable UTP Connector ï u Video Coaxial Cable Back Box Circuit Board ñ ~í 16-Pin Connector Audio Connectors ó ~â Heat Sink Standoff TXB-N r Captive Screw C3468M (4/10) 13
Summary of the content on the page No. 14
3. Connect the auxiliary, alarm, and other wiring to the back box circuit board (refer to Figure 9). NOTES: � Aux 1: Maximum 2 A at low voltage (<40 V) Aux 2: Maximum 30 mA at 32 VDC � If you are installing an environmental back box in a railway application, attach a ground wire from the circuit board power connector to a structural ground using at least 18-gauge wire. 1 2 3 ALARMS 4 5 6 7 GND NO AUX1 COM NC AUX2 GND VIDEO PWR- GND PWR+ RX- RX+ TX- TX+ UTP+ UTP- Figure 9. Connect the Wiring to
Summary of the content on the page No. 15
4. If you plan to use the audio functions, install your audio cables into the audio line-in and line-out connectors on the TXB-N. NOTES: � To take full advantage of the distance and noise immunity benefits of audio, you must use a 600-ohm impedance matching transformer and twisted pair cable (refer to Figure 10). � A stable power supply is required for optimal audio performance. Figure 10. Connecting Audio to the TXB-N ì ó Microphone Line-Out Audio Twisted Pair Cable î r Amplifier 600-Ohm Impe
Summary of the content on the page No. 16
5. Reinstall the TXB-N: a. Plug the TXB-N into the 16-pin connector located on the back box circuit board. b. Secure the TXB-N to the standoff on the circuit board using the captive screw on the TXB-N. 6. Plug your network Ethernet cable into the RJ-45 connector on the TXB-N to connect the Spectra IV dome system to your existing network. WARNING: An electrical short in the back box may occur if the metal BNC connector on the video coaxial cable is not completely covered by the protective boot.
Summary of the content on the page No. 17
Table A. Video Coaxial Cable Requirements Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) *Cable requirements: � 75-ohm impedance � All-copper center conductor � All-copper braided shield with 95 percent braid coverage Refer to Table B for the recommended maximum distances for 24 VAC and 24 VDC applications, which are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC- or DC-powered d
Summary of the content on the page No. 18
Installing the Dome Drive 1. Perform one of the following options: � View video using both analog and IP connections: Set the DIP switches on the top of the Spectra IV dome drive (refer to Figure 12). For DIP switch settings, refer to the labels located on the top of the dome drive, or refer to Switch Settings on page 28. � View video using the IP connection: You do not need to set the DIP switches. NOTE: When connecting more than one Spectra dome to a single controller, terminate the unit f
Summary of the content on the page No. 19
Installing the Lower Dome IN-CEILING 1. Snap the clip on the end of the trim ring leash into the hole on the lip of the back box (refer to Figure 13). Figure 13. Installing the In-Ceiling Lower Dome 2. Snap the trim ring into the plastic snap washers on the mounting screws. C3468M (4/10) 19
Summary of the content on the page No. 20
HEAVY-DUTY IN-CEILING 1. Snap the clip of the lower trim ring leash into the hole on the lip of the back box (refer to Figure 14). 2. Insert both keys in the barrel locks. Turn the keys clockwise to the unlocked position. NOTE: Keys cannot be removed from the lock while in the unlocked position. 3. Align the ball studs, located on the mount ring, with the ball stud receivers, located on the inside of the lower dome. Push the lower dome into the back box. 4. Hold and turn both keys to the locked