Summary of the content on the page No. 1
Control/Communicator D7212G
Operation and Installation Guide
Summary of the content on the page No. 2
D7212G Operation and Installation Guide D7212G Operation and Installation Guide 4998138544C Page 2 © 2003 Bosch Security Systems
Summary of the content on the page No. 3
D7212G Contents 1.0 Introduction .........................................................................................................................................................9 1.1 Guide Organization .............................................................................................................................................................. 9 1.2 Related Documentation ......................................................................................................
Summary of the content on the page No. 4
D7212G Contents 4.0 Power Supply .................................................................................................................................................. 25 4.1 Primary Power Terminals ................................................................................................................................. 25 4.1.1 Primary (AC) Power Circuit ...........................................................................................................................
Summary of the content on the page No. 5
D7212G Contents 8.0 Off-board Points ............................................................................................................................................ 37 8.1 Point (ZONEX) Bus D7212G Terminals ..............................................................................................37 8.2 D8125, D8127 and D9127 POPIT Modules .............................................................................................................. 38 8.2.1 Listings .............
Summary of the content on the page No. 6
D7212G Contents 11.5 SDI Address 88 .................................................................................................................................................................. 54 11.5.1 D9133DC Direct Connect Programming Module ...................................................................................................... 54 11.5.1.1 Connecting the D9133DC ...............................................................................................................
Summary of the content on the page No. 7
D7212G Contents Figures Figure 1: System Configuration...................................................................................................................................................... 13 Figure 2: Enclosure Mounting ......................................................................................................................................................... 21 Figure 3: Ground Fault Detect.............................................................................
Summary of the content on the page No. 8
D7212G Contents Tables Table 1: D7212G Operation and Installation Guide Organization ......................................................................................... 9 Table 2: Related Documentation .................................................................................................................................................... 10 Table 3: Differences between the 9000G Series Panels .......................................................................................
Summary of the content on the page No. 9
D7212G Introduction 1.0 Introduction This guide addresses the operation and installation of the D7212G Control/Communicator only and should not be used in conjunction with the D9412G, D7412G, D9412, D9112, D9112B1, D7412, D7212 or D7212B1 Panels. Throughout this guide, unless expressly stated, the words “panel” and “control/communicator” refer to the D7212G. Section 2.1 9000G Series Panel Differences on page 13 provides an overview of the differences between the D9412G, D7412G, and D7212G panels
Summary of the content on the page No. 10
D7212G Introduction 1.2 Related Documentation Table 2 is a comprehensive list of all documentation (with part numbers) directly related to the D7212G Control/ Communicator. Throughout this guide, references are made to this documentation. If you need one or more of these documents, please contact Bosch Security Systems Technical Support and request the documentation by part number. Name of Document Part Number D1255 Installation Instructions 74-06819-000 D1256/D1257 Installation Instructions 74-
Summary of the content on the page No. 11
D7212G Introduction 1.3.2 Tips, Notes, Cautions and Warnings Throughout this document helpful tips and notes will be presented concerning the entire application and/or programming the unit. They will be set off as follows: Application Notes should be heeded for successful operation and programming. Helpful tips and/or shortcuts may be included here. Application Note Cautions the operator that physical damage to the equipment or improper execution of the program may occur. CAUTION Warns of possib
Summary of the content on the page No. 12
D7212G Introduction Notes: D7212G Operation and Installation Guide 4998138544C Page 12 © 2003 Bosch Security Systems
Summary of the content on the page No. 13
D7212G Overview 2.0 Overview Each D8128D OctoPOPIT combines D8129 OctoRelay provides alarm eight POPIT points in one module. and auxilliary relay output. (Other functions available.) Control/ Communicator D8125 or D8125MUX Interface D9133TTL-E allows communication used for point expansion. over a Local or Wide Area network. On-Board Points 1 to 8 Use command centers and/or keyswitches to arm the D8132 Modules (two 12 VDC, 7Ah batteries) panel by area. Each panel can have up to four areas. provid
Summary of the content on the page No. 14
D7212G Overview 2.2 Specifications (The black and white circles with numbers indicate the specific panel terminal.) Voltage Input Primary: 16.5 VAC 40 VA class 2 plug-in transformer (D1640) (Power Supply) Secondary: Sealed lead-acid rechargeable (12 VDC, 7 Ah or 12 VDC, 17.2 or 18 Ah) battery. The panel supports a maximum of two 12 VDC, 7 Ah batteries using the D122 Dual Battery Harness or two D1218 (12 VDC, 17.2 or 18 Ah) batteries using a D122. Current Requirements Panel : 500 mA alarm, 200 mA
Summary of the content on the page No. 15
D7212G Overview Telephone Connections Telephone Line RJ31X or RJ38X jack can be interfaced with the panels. Connection Supervision supplied by the panel. Battery Discharge Cycle 13.9 VDC Charging float level Discharge/Recharge 13.8 VDC Charging Status LED on Schedule 12.1 VDC Low Battery & AC Fail reports if programmed, Low Battery LED on 10.2 VDC Battery load shed (processing functions continue if AC is present) Recharge Cycle AC ON Load shed relay resets battery charging begins, Battery Troubl
Summary of the content on the page No. 16
D7212G Overview 2.2.1 Compatible Accessories See the Bosch Security Systems Intrusion Catalog for a complete list. D122 Dual Battery Harness D1256 Fire Command Center D125B Powered Loop D1257 Fire Annunciator Interface Module D126 12 V, 7 Ah D1260 Alpha V Command Center Rechargeable Battery D127 Reversing Relay D1640 16.5 VAC 40 VA Transformer D129 Dual Class A Initiation D5200 Programmer Circuit Module D130 Relay Module D5500 Remote Account Manager IV D136 Plug-In Relay D8004 Transformer Enclos
Summary of the content on the page No. 17
D7212G Overview 2.3.3 Added Feature When Using Ground Fault Detect When Ground Fault Detect is enabled (S4 closed), Points 1-8 can be used for non-powered fire-initiating devices, such as Heat Detectors, 4-Wire Smoke Detectors, Pull Stations, etc. A D125B Powered Loop Interface or a D129 Dual Class A Interface Module is no longer required when connecting non-powered fire-initiating devices to Points 1 through 8. 2.3.4 NetCom Functionality The D6600 NetCom System supports data network communicati
Summary of the content on the page No. 18
D7212G Overview 2.4.4 Command Centers A maximum of 32 unsupervised command centers can be connected to the system. The available power, number of supervised command centers, and number of areas that will be used, affect the total number of command centers that can be connected. The system can supervise up to eight command centers. The panel transmits a serial device trouble report SDI FAILURE in 2 the Modem IIIa format or TROUBLE ZN D in the BFSK format, if it loses communication with a supervi
Summary of the content on the page No. 19
D7212G Overview 2.4.10 Other Features The D7212G Control/Communicator has many programmable features. A short list of some of the features follows. Complete details on all the features can be found in the D7212G Program Entry Guide (P/N: 4998138538). Supervision of AC (primary power), battery (secondary power), ZONEX and SDI buses, the CPU (Central Processing Unit), up to three printers, and two telephone lines Automatic system test reports Remote access for programming, diagnostics, and l
Summary of the content on the page No. 20
D7212G Overview The following literature is available in a separate literature package for dealers: - D7212G Approved Applications Compliance Guide (P/N: 4998138560) - D7212G Operation and Installation Guide (P/N: 4998138544) - D7212G Program Entry Guide (P/N: 4998138538) - D7212G Program Record Sheet (P/N: 4998138542) - D7212G Release Notes (P/N: 4998138543) - D9412G/D7412G/D7212G Installation and Troubleshooting Quick Reference Guide (P/N: 43700) - 9000/9000G Series Technogram: Smoke Detector