Aiphone LEW-5-NE user manual

User manual for the device Aiphone LEW-5-NE

Device: Aiphone LEW-5-NE
Category: Home Security System
Manufacturer: Aiphone
Size: 0.1 MB
Added : 10/2/2013
Number of pages: 5
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Aiphone LEW-5-NE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Aiphone LEW-5-NE.

For your convenience

If looking through the Aiphone LEW-5-NE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Aiphone LEW-5-NE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Aiphone LEW-5-NE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Aiphone LEW-5-NE User manual - Online PDF
Advertisement
« Page 1 of 5 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Aiphone LEW-5-NE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Aiphone LEW-5-NE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

0113
LEF-5-NE/LEW-5-NE
5-call Master Station
Master Station for use with the NEM and NDR Systems
- INSTRUCTIONS -
The LEF-5-NE is a 5-station master, equipped with a door release button, and able to integrate into a larger
NEM or NDR system. In applications where up to 5 door stations needs to be answered from the main NEM/
NDR master as well as additional small master stations, the LEF-5-NE can be used. The LEW-5-NE adaptor
is required. This system can be used with the following subs: NE-D

Summary of the content on the page No. 2

WIRING DIAGRAM: using NE-SS/SSR and NE-NVP-2DC-LE subs LEW-5-NE/B NE-SS/SSR NDR-40 Adaptor 1 N1 D1 Red 2 N2 D2 Blk 3 N3 D3 Wht 4 N4 D4 Grn wire 5 N5 D5 ~ 40 Wire each door E NE station to a H H designated number station Q Q as shown here. PS-2420UL + + - - LEF-5-NE NE-NVP-2DC-LE 1 L1 To Door K1 K1 Red NOTE: "K" Strike for Yel RY-PA Blk L2 Blk 2 Terminal Door #1 connections are Diode value: K2 K2 Wht required in this 1N4001 ~ 4007 L3 Pur 3 application, with Blu K3 K3 or without door

Summary of the content on the page No. 3

WIRING DIAGRAM: using NE-NVP-RA and NE-NVP/C subs LEW-5-NE/B NDR-20A-RS NE-NVP-RA Adaptor 1 N1 D1 Red 2 N2 D2 Blk 3 N3 D3 Gray 4 N4 D4 5 N5 D5 Grn wire ~ 20 NAR-2A* E NE Blue Blue H H Pur Blue Q Q Org PS-2420UL S Yel + + * Reset Button: - - (Any normally closed LEF-5-NE button or keyswitch. Not required when 1 L1 To Door using the NEM-RS K1 K1 master.) NOTE: "K" Strike for RY-PA Yel Blk 2 L2 Terminal Door #1 connections are Diode value: K2 K2 NE-NVP/C required in this 1N4001 ~ 4007 L3

Summary of the content on the page No. 4

WIRING DIAGRAM: with no NEM or NDR master being used LEW-5-NE/B NE-NVP-2DC-LE Adaptor N1 D1 Red N2 D2 Blk N3 D3 Wht N4 D4 Pur N5 D5 Blu Grn PS-1225UL wire - NE Org + H Org Q Yel Yel Connect with wires LEF-5-NE LEF-5-NE of the standard call button to activate a call when the 1 1 L1 RED button is pressed. K1 K1 K1 2 2 L2 K2 3 3 L3 K3 4 4 L4 K4 L5 5 C C 5 K5 E E LE R R RF L L + + + - - - PS-1225UL Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 Toll Free Technical Support:

Summary of the content on the page No. 5

OPERATION: 1. Pressing the call button at the door/sub station will activate the call tone, plus light the appropriate station LED at the NEM/NDR master. The call tone will be heard at the LEF-5-NE master(s) continually until the call is answered from any master in the system. 2. To answer the call on the LEF or NEM/NDR master, press the station button corresponding to the lit LED, then press TALK to speak to the visitor. When the first master answers the call, the Occupied lamp will


Alternative user manuals
# User manual Category Download
1 Aiphone AI-RS150 AI-RS160 AI-RS170 AI-RS180 User manual Home Security System 1
2 Aiphone AI-RS180 User manual Home Security System 0
3 Aiphone 0102bkjd User manual Home Security System 0
4 Aiphone AP-5M User manual Home Security System 2
5 Aiphone AC-10F User manual Home Security System 13
6 Aiphone AI-RS170 User manual Home Security System 1
7 Aiphone AI-RS150 User manual Home Security System 0
8 Aiphone AI-900 User manual Home Security System 3
9 Aiphone KC-DAR User manual Home Security System 1
10 Aiphone LEM-1DL User manual Home Security System 0
11 Aiphone MKW-DK/A User manual Home Security System 0
12 Aiphone LEF User manual Home Security System 0
13 Aiphone LE-SSV User manual Home Security System 0
14 Aiphone JF-DVF-HID-I User manual Home Security System 0
15 Aiphone LS-NVP-W User manual Home Security System 0
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9