Vista Ademco N7227V5 user manual

User manual for the device Vista Ademco N7227V5

Device: Vista Ademco N7227V5
Category: Home Security System
Manufacturer: Vista
Size: 0.65 MB
Added : 4/9/2013
Number of pages: 100
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vista Ademco N7227V5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vista Ademco N7227V5.

For your convenience

If looking through the Vista Ademco N7227V5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vista Ademco N7227V5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vista Ademco N7227V5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vista Ademco N7227V5 User manual - Online PDF
Advertisement
« Page 1 of 100 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vista Ademco N7227V5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vista Ademco N7227V5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



• •
• •
• •
• •
• •








  

AWAY NO AC
ARMED
STAY CHIME
ALARM INSTANT BAT
CHECK BYPASS READY
FIRE NOT READY
OFF AWAY STAY
1 2 3
MAX TEST BYPASS
4 5 6
INSTANT CODE CHIME
7 89
READY
0 #
*
PANIC
®
N7227V5 10/00
*




Summary of the content on the page No. 2

RECOMMENDATIONS FOR PROPER PROTECTION The following recommendations for the location of fire and burglary detection devices help provide proper coverage for the protected premises. Recommendations for Smoke and Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early-warning fire detection is best achieved by the installation of fire detection

Summary of the content on the page No. 3

Table of Contents •••••••••••••••••••••••••••••••••••••••••••••••••• SECTION 1. Introduction............................................................................................................................1–1 Description ........................................................................................................................................................1-1 Features........................................................................................................

Summary of the content on the page No. 4

SECTION 11. Final Power-Up ....................................................................................................................11–1 Earth Ground Connections ............................................................................................................................11-1 Wiring the AC Transformer ...........................................................................................................................11-1 AC Power-Up ................................

Summary of the content on the page No. 5

SECT ION 1 Introduction •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Description Features •••••••••••••••••••••••••••••••••••••••••••••••••• Description The VISTA–10SE is a control that supports up to 22 hardwired and wireless zones, plus remote keypads. Features Basic Hardwired Zones Provides 6 basic hardwired zones having the following characteristics: • Zones 1-6 response time is 300–500 milliseconds. • Zone 3 programmable fast response time is 10–15 milliseconds. •

Summary of the content on the page No. 6

VISTA-10SE Installation and Setup Guide Security Codes  One Master code for entire system (User 2). Installer code is User 1.  4 secondary user codes (Users 3–6).  One duress code (User 8). Duress Code: An emergency code that, when used to disarm or arm the system, will send a . silent duress message to the central station Keypad Panic Keys • Up to 3 programmable panic key functions are provided. • Designated as Zones 7, 95, 96. • Activated by wired and wireless keypads. • Reported separate

Summary of the content on the page No. 7

Section 1 - Introduction Alarm Output • Provides a 12VDC, 2 AMP output that can drive the compatible sounders listed in the EXTERNAL SOUNDERS section (assumes a fully charged battery is connected). • Steady output for burglary/panic, or temporal pulse sounding output for fire notification, as required by UL. • Uses current-limiting circuitry for protection. Auxiliary Power Output • Provides 12VDC, 500mA maximum. Uses current limiting circuitry for protection. • This output interrupts for smoke d

Summary of the content on the page No. 8

VISTA-10SE Installation and Setup Guide 1-4

Summary of the content on the page No. 9

SECT ION 2 Installing the Control •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Mounting the Control and RF Receiver Circuit Mounting the Cabinet Board in the Cabinet Installing the Lock Standard Phone Line Connections Mounting the Control's Circuit Board Alone in the Cabinet •••••••••••••••••••••••••••••••••••••••••••••••••• Mounting the Cabinet Mount the control cabinet to a sturdy wall using fasteners or anchors (not supplied), in a clean, dry area that is not r

Summary of the content on the page No. 10

VISTA-10SE Installation and Setup Guide Mounting the Control's Circuit Board Alone in the Cabinet To mount the circuit board alone in the cabinet, follow these steps: 1. Hang two mounting clips* (provided) on the raised cabinet tabs (see Detail B in Figure 2 below). 2. Insert the top of the circuit board between the rows of slots at the top of the cabinet as shown in Detail A. 3. Position the base of the board onto the mounting clips and secure both to the cabinet with the supplied screws (see D

Summary of the content on the page No. 11

Section 2 - Installing the Control HOLES FOR ANTENNAS CABINET AND GROUNDING LUGS CIRCUIT BOARD BOARD RECEIVER CIRCUIT BOARD SUPPORTING DETAIL A (See Detail D) SLOTS SIDE VIEW + + OF BOARD SUPPORTING SLOTS MOUNTING CLIP CONTROL CIRCUIT BOARD MOUNTING CLIP DETAIL B SIDE VIEW SCREW OF MOUNTING (2) CLIP ANTENNA (2) GROUNDING LUG (2) CABINET DETAIL C RCVR BRD SIDE VIEW OF MOUNTING + + CLIP ANTENNA MOUNT (2 PLACES) DETAIL D ANTENNA AND GROUNDING LUG INSTALLATION V10SE-004-V0 Figure 3. Mounting the PC

Summary of the content on the page No. 12

VISTA-10SE Installation and Setup Guide INCOMING TELECOM LINE HANDSET 17 18 19 20 21 TERMINALS ON CONTROL EARTH GROUND INCOMING TELECOM LINE PLUG TIP RJ31X JACK PREMISES RING PHONES DIRECT CONNECT CORD V10SE-024-V0 Figure 4. Standard Telephone Line Connections 2-4 BROWN (TIP) GREY (RING) GREEN (TIP) RED (RING) GROUND TIP RING

Summary of the content on the page No. 13

SECT ION 3 Remote Keypads •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Keypads That May Be Used Supplementary Power for Additional Keypads Wiring to the Keypads Preliminary Checkout Procedure Mounting the Keypads •••••••••••••••••••••••••••••••••••••••••••••••••• This section lists the wired keypads that may be used and provides instructions for wiring and mounting the keypads. A preliminary checkout procedure is also provided to ensure that the connected keypads

Summary of the content on the page No. 14

VISTA-10SE Installation and Setup Guide Wiring Run Chart for Devices* Drawing Aux Power From the Control (12V+ & 12V–) TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE RUN Wire Size 50mA or less 100mA 300mA 500mA #22 500 ft (152m) 250 ft (76m) 80 ft (24m) 50 ft (15m) #20 750 ft (228.6m) 380 ft (116m) 130 ft (39.6m) 80 ft (24m) #18 1300 ft (396m) 650 ft (198m) 220 ft (67m) 130 ft (39.6m) #16 1500 ft (457m) 1000 ft (305m) 330 ft (100.5m) 200 ft (70m) * Includes keypads, RF receivers,

Summary of the content on the page No. 15

Section 3 - Installing Remote Keypads Keypads powered from supplies that do not have a backup battery will not function when AC power is lost. Therefore, be sure to power at least one keypad from the Control's auxiliary power output. Connect the additional keypads as shown in Figure 6, using the keypad wire colors shown. Be sure to observe the current ratings for the power supply used. Make connections directly to the screw terminals as shown in Figure 6. Make no connection to the keypad blue wi

Summary of the content on the page No. 16

VISTA-10SE Installation and Setup Guide If the “Ready” message is not displayed on any of the keypads in the system, or a “Not Ready” message is displayed, check the keypad wiring connections, and make sure each of the 6 basic hardwired zones has a 1000 ohm resistor connected across its terminals. Do not remove the EOL resistors until you are ready to make connections to the hardwired zones, to allow for testing later in the manual. If an OC or OPEN CIRCUIT display is present on the keypad, data

Summary of the content on the page No. 17

SECT ION 4 Basic Hardwired Zones 1–6 •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section Installing the Hardwired Zones Programming Hardwired Zones •••••••••••••••••••••••••••••••••••••••••••••••••• Installing the Hardwired Zones Common Characteristics for Zones 1–6 • Response time from 300 - 500 milliseconds (400 milliseconds nominal). • Zone 3 can be programmed (in field ✱ 52) for normally-closed sensor fast response (10mSec max) to an open (suitable for vibration type conta

Summary of the content on the page No. 18

VISTA-10SE Installation and Setup Guide 3. To meet NFPA 72 requirements, you must use a supervisory module to supervise power (e.g., System Sensor No. A77-716B Relay module). + 5 AUX PWR OUTPUT _ BLK + RED TERMINALS _ 4 4-WIRE SMOKE EOL OR COMBUSTION POWER DETECTORS SUPERVISION + + RELAY MODULE _ _ A77-716B VIOLET 1000 OHMS TO HI SIDE OF + EOLR HEAT HEAT ZONE 5 DETECTOR DETECTOR _ V10SE-010-V0 TO LO SIDE Figure 7. 4-wire Smoke Detector Connections (Zone 5) Compatible System Sensor 4-Wire Smoke/

Summary of the content on the page No. 19

SECT ION 5 Wireless Expansion (5800 System) •••••••••••••••••••••••••••••••••••••••••••••••••• In This Section About Wireless Expansion About Jam Detection and Reporting Installing the 5881/5882 Receiver 5800 Series Transmitters Installing the 5800TM Module Installing 5800 Series Transmitters •••••••••••••••••••••••••••••••••••••••••••••••••• About Wireless Expansion The VISTA-10SE supports up to 16 wireless zones that may be used exclusively or in addition to hardwired zones 1 throu

Summary of the content on the page No. 20

VISTA-10SE Installation and Setup Guide Installing the 5881/5882 Receiver RF System Installation Advisories Follow the guidelines below when installing the RF receiver. (Disregard if the receiver is mounted in the control cabinet.) • Place the RF receiver in a high, centrally located area for best reception. • Do not locate the receiver or transmitters on or near metal objects. This decreases range and/or block transmissions. • Do not locate the receiver in an area of high RF interference (revea


Alternative user manuals
# User manual Category Download
1 Vista Ademco -10SE User manual Home Security System 286
2 Vista -20SE User manual Home Security System 8
3 Vista -20HWSE User manual Home Security System 0
4 3Com 1000BASE-T-GBIC User manual Home Security System 0
5 Sony BRCSDP12 User manual Home Security System 3
6 3Com TECHD-0000000122 User manual Home Security System 1
7 Sony SSC-M354 User manual Home Security System 3
8 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
9 Sony SNC-RX SNC-CS50 User manual Home Security System 4
10 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
11 Sony CD-7226 User manual Home Security System 1
12 Sony Ssc-M383 User manual Home Security System 6
13 Sony Snc Df50n User manual Home Security System 1
14 Sony SNC-RX SNC-RZ50 User manual Home Security System 20
15 Sony BLUETOOTH MEX-BT2500 User manual Home Security System 10