Samsung SSA-P401 user manual

User manual for the device Samsung SSA-P401

Device: Samsung SSA-P401
Category: Home Security System
Manufacturer: Samsung
Size: 2.71 MB
Added : 8/21/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Samsung SSA-P401. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Samsung SSA-P401.

For your convenience

If looking through the Samsung SSA-P401 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Samsung SSA-P401 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Samsung SSA-P401 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Samsung SSA-P401 User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Samsung SSA-P401 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Samsung SSA-P401. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SSA-P400
SSA-P400T
SSA-P401
SSA-P401T
Access Control Panel
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
www.samsungsecurity.com

Summary of the content on the page No. 2

safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accom

Summary of the content on the page No. 3

SAFETY INFORMATION 5. Keep out of direct sunlight and heat radiation sources. It may cause fi re. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time. FCC Statement This device comp

Summary of the content on the page No. 4

contents 5 Features PRODUCT INTRODUCTION 7 What’s included 12 Cable Selection 5 13 Connecting the termination resistor and INSTALLATION AND EXTERNAL diode CONNECTION 14 Earth-grounding the communication cables 15 Power, Reader, and I/O Connection 18 Communication Line Connection 13 22 System Initialization INITIALIZATION 23 Board ID Setting 22 24 Troubleshooting TROUBLESHOOTING 24 26 Product Specifi cations PRODUCT SPECIFICATIONS 26 4_ contents

Summary of the content on the page No. 5

PRODUCT INTRODUCTION product introduction FEATURES State-of-the-art Access Controller SSA-P400(T)/SSA-P401(T) is a state-of-the-art door access controller device that provides a high level security system in an affordable price, meeting the needs in the security industry. SSA-P400(T)/SSA-P401(T) can control access of 2-4 doors with simple manipulation and high level stability as well as its affordable cost. You can specify up to 1000 ~ 20,000(30,000/ 40,000/50,000) instances of card registrat

Summary of the content on the page No. 6

product introduction Input Port Format Setup 15 input ports are provided by default. For these ports, you can specify if the format of the incoming signal is blocked (NO) or connected (NC) in normal operation. This setting will make all ports operate same regardless of the output status of the input device. Time Scheduling You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range for a schedule code, which will be transferred to the app

Summary of the content on the page No. 7

PRODUCT INTRODUCTION WHAT’S INCLUDED Check if the following items are included in the product package. Main Unit Quick Guide Diode (x12) CD Manual (UF4004, 1N4001~4007) English7

Summary of the content on the page No. 8

product introduction Main Board 1 2 3 24 25 4 23 22 16 5 21 17 6 20 15 7 19 10 8 18 9 14 13 12 11 Board ID Setup The address number specifi ed by the address setup switch should match that of the 1 Switch host computer as it is used for communications with the host computer. I/O Board Connection Communication ports to connect to the I/O board, which include Input #8 through Input 2 Port #15 and Output #8 through Output #15. Pressing both of the switches at the same time for about 2 seconds will

Summary of the content on the page No. 9

PRODUCT INTRODUCTION 6 RJ-45 Connect the LAN cable for TCP/IP communications. RS-232 One RS-232 communication port is provided. Used to exclusively connect to a PC in a Communication 7 local area. Port RS-422 One RS-422 communication port is provided. 8 Communication You can establish up to 32 multi-drop communications. Port Power Connection 9 DC +12V is used for the power source. Port Port used to extend the power and communication indicators so that they can display LED Extension Port 1

Summary of the content on the page No. 10

product introduction I/O Board 1 2 3 19 4 20 18 5 6 17 16 7 15 8 14 9 21 13 10 11 12 Fixing Hole Used to fi x the main board to the I/O board using screws. 1 Power LED Indicator The red indicator turns on in the normal power supply condition. 2 Main Board Connection Connector used to connect to the main board. 3 Port Output (Relay #5) Port Output port #5. 4 Output (Relay #6) Port Output port #6 (FORM-C). 5 Output (Relay #7) Port Output port #7 (FORM-C). 6 Output (Relay #8) Port Output port #8 (F

Summary of the content on the page No. 11

PRODUCT INTRODUCTION INPUT #8 Input port #8. 8 INPUT #9 Input port #9. 9 INPUT #10 Input port #10. 10 INPUT #11 Input port #11. 11 INPUT #12 Input port #12. 12 INPUT #13 Input port #13. 13 INPUT #14 Input port #14. 14 INPUT #15 Input port #15. 15 Output (Relay #9) Port Output port #9 (FORM-C). 16 Output (Relay #10) Port Output port #10 (FORM-C). 17 Output (Relay #11) Port Output port #11 (FORM-C). 18 Output (Relay #12) Port Output port #12 (FORM-C). 19 Output LED Indicator LED Indicator that ind

Summary of the content on the page No. 12

product introduction CABLE SELECTION RS-232 RS-422/RS-232 Converter HOST P.C. RS-422 RS-422 RS-422 DC12V DC12V Power Supply Power Supply RF Reader Lock/Alarm RF Reader Lock/Alarm Exit Button/Sensor Input Exit Button/Sensor Input Item C Cable Type able Type Power (DC12V) Belden #9409, 18 AWG 2 Conductor, Unshielded Belden #9409, 18 AWG 2 Conductor, Unshielded 1 DC Power Device Belden #9512, 22 AWG 4 Conductor, Shielded Reader (power and

Summary of the content on the page No. 13

INSTALLATION AND EXTERNAL CONNECTION installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor A resistor is inserted for matching the line’s impedance to prevent distortion and reduction in RS-422 or RS-485 long distance data communications, which is referred to as termination resistor. Note that termination resistors of lower than 90 are not allowed, neither more than one termination resistor is accepted for the communications system. A RS-485

Summary of the content on the page No. 14

installation and external connection EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable. However, the earth-grounding of the communication cable is not easy at all, and it also causes an increased installation cost. There are three grounding points available for installation: 1. Earth Ground 2. Chassis Ground 3. Power Ground The mo

Summary of the content on the page No. 15

INSTALLATION AND EXTERNAL CONNECTION POWER, READER, AND I/O CONNECTION Power Connection DC +12V GND - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the GND (-) line of DC 12V to the GND (-) port. Reader Connection Reader #4 Reader #1 Reader #3 Reader #2 GND D1 D0 DC+12V - Connect the plus (+) line of the reader to the corresponding port (DC +12V). - Connect the minus (-) line of the reader to the GND (-) port. - Connect the data 0 line of the reader to its port

Summary of the content on the page No. 16

PUSH PUSH installation and external connection Input Connection GND Input #7 GND Input #6 GND Input #5 GND Input #4 Door Open Sensor GND Exit Button Input #3 GND Input #2 Door Open Sensor GND Exit Button Input #1 - Exit Button Connection (Input #1, Input #3) 1. Connect one line of the Exit button to an input port (Door 1: Input #1, Door 2: Input #3) of the Exit button. 2. Connect the other line of the Exit button to GND (-). - Door Sensor Connection (Input #2, Input #4) 1. Connect one line (COM)

Summary of the content on the page No. 17

INSTALLATION AND EXTERNAL CONNECTION Output Connection DC +12V GND Door Lock NC POWER FAIL SAFE COM COM NO Alarm Device GND POWER FAIL SECURE - If the door lock is in POWER FAIL SAFE mode: (Door 1: Relay #1, Door 2: Relay #3) 1. Connect the COM line of the Door Lock relay to DC +12V. 2. Connect the plus (+) line of the Door Lock to the Normal Close (NC) line of the Door Lock relay. 3. Connect the minus (-) line of the Door Lock to GND (-). - If the Door Lock is in POWER FAIL SECURE mode: (Door 1

Summary of the content on the page No. 18

installation and external connection COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: HOST PC RS-232 2 3 5 9-Pin Female Connector 1. Connect RS-232 TX to pin #2 of the 9-pin connector. 2. Connect RS-232 RX to pin #3 of the 9-pin connector. 3. Connect RS-232 GND to pin #5 of the 9-pin connector. 4. Connect the serial communication

Summary of the content on the page No. 19

INSTALLATION AND EXTERNAL CONNECTION RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: RS-422/232 Converter RxD RS-232C TxD Power HOST T+ T- R+ R- MAX. 1200m TX- TX+ RX- RX+ 1. Connect RS-422 TX(-) to the RX(-) port of the converter. 2. Connect RS-422 TX(+) to the RX(+) port of the converter. 3. Connect RS-422 RX(-) to the TX(-) port of the converter

Summary of the content on the page No. 20

installation and external connection RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications. RS-422/232 Converter RxD RS-232C TxD Power T+ T- R+ R- HOST MAX. 1200m TX- TX+ RX- RX+ - Follow the guidelines below to make connection between devices. 1. Connect TX(-) of one device to TX(-) of other one. 2. Connect TX(+) of one device to TX(+) of other one. 3. Connect RX(-) of one device to RX(-) of other one. 4. Connect RX(+) o


Alternative user manuals
# User manual Category Download
1 Samsung 720p Hdtv Camera SDC8340BU User manual Home Security System 29
2 Samsung Scc-B2305 User manual Home Security System 35
3 Samsung 4 Channel Sd Dvr SDR3100 User manual Home Security System 17
4 Samsung SPD-2300 User manual Home Security System 4
5 Samsung 4 Channel 4 Camera Sd Kit SDSV3040 User manual Home Security System 3
6 Samsung SCV-2080R User manual Home Security System 11
7 Samsung Sbr-100dcm User manual Home Security System 9
8 Samsung SHG-220S User manual Home Security System 1
9 Samsung 8 Channel Hdtv Hybrid Dvr SDR4200 User manual Home Security System 23
10 Samsung SMC-213 User manual Home Security System 2
11 Samsung Scc-C6475 User manual Home Security System 1
12 Samsung SHG-220 User manual Home Security System 10
13 Samsung Sadt-110cm User manual Home Security System 1
14 Samsung SMO-150QN User manual Home Security System 0
15 Samsung SSA-C120 User manual Home Security System 0
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9