Summary of the content on the page No. 1
ADDENDUM
Addendum No. C1573M
Date February 1, 2006
Manuals Affected C1572M, C1555M-F, C1566M-C
Manual Update The front and rear mounting rails and the mounting brackets are no longer supplied with the CM9700-CC1.
Disregard the CM9700-CC1 mounting information in the above referenced manuals.
To mount the CM9700-CC1 into a standard 19-inch EIA rack follow these instructions:
1. Insert the CM9700-CC1 into the rack.
2. Tighten the CM9700-CC1 to the rack using the four supplied Phi
Summary of the content on the page No. 2
INSTALLATION/OPERATION ® System 9760 Video Matrix Switching Control System C1572M (9/05)
Summary of the content on the page No. 3
Summary of the content on the page No. 4
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 System Overview . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 5
Setting and Adjusting System Time in a Single-Node System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 Setting and Adjusting System Time in a Multi-Node System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 DOS Filename Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 6
List of Illustrations 1 Basic Components of a 9760 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 2 Mounting the CM9700-CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 3 CM9700-CC1 Connections . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 7
60 ACD DB9 to CM9700-CC1 DB9 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 61 ACD DB9 to CM9700-CC1 RJ-45 Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 62 Sideframing: 736 x 16 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 8
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose o
Summary of the content on the page No. 9
Regulatory Notices CM9700-CC1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These
Summary of the content on the page No. 10
System Overview ® This section provides an overview of the System 9760 video matrix switching control system, hereinafter referred to simply as the 9760 system. The following information is provided: Description of the basic components of the 9760 system Summary listing of 9760 system device models and compatible equipment DESCRIPTION The 9760 system allows control and monitoring of up to 2,048 video input devices (for example, cameras) and 512 video output devi
Summary of the content on the page No. 11
Note the following: To ensure uninterrupted operation, the 9760 system can be equipped with a backup CM9700-CC1 by means of a CM9760-HS hot switch. For detailed information about the CM9760-HS, refer to the CM9760-HS Hot Switch Installation/Operation manual. The CM9700-NW1, commonly referred to as the network interface unit (NIU), can be used to connect two or more CM9700-CC1 units to create a networked system. Each CM9700-CC1 unit and attached devices comprise a node in
Summary of the content on the page No. 12
NETWORK INTERFACE UNIT CM9700-NW1 Network CPU and software necessary for joining two or more independent systems together. Allows multiple systems to share video and control. Commonly referred to as the network interface unit (NIU). OPTIONAL COMPONENTS CM9760-ALM Alarm interface unit. Connects directly to each system. Each unit can monitor up to 64 alarms. Up to four units can be connected in a series from one SERCOM port. CM9760-CDU-T Code distribution unit. Sixteen-chan
Summary of the content on the page No. 13
System Setup This section provides information about the following: Overview of tasks necessary to set up a 9760 system Unpacking the CM9700-CC1 controller and CM9760-MXB matrix bay Installing the CM9700-CC1 controller Installing CM9760-MXB matrix bay(s) Verifying system operation SYSTEM SETUP OVERVIEW The following provides an overview of the tasks necessary to set up a 9760 system and prepare the system for operation. It is recommended that you
Summary of the content on the page No. 14
UNPACKING Various items are supplied with the CM9700-CC1 and with the CM9760-MXB. Refer to the Unpacking the CM9700-CC1 and Unpacking the CM9760-MXB sections for a list of items supplied with the units. UNPACKING THE CM9700-CC1 The following items are supplied with the CM9700-CC1: 1 CM9700-CC1 unit, with front rack ears installed 1 120 VAC, 60 Hz power cord (USA standard) 1 230 VAC, 50 Hz power cord (European standard) 1 Keyboard, PS/2 1 PS/2-to-AT keyboard adapter 1 BNC extractio
Summary of the content on the page No. 15
INSTALLING THE CM9700-CC1 CONTROLLER Installation of the CM9700-CC1 includes the following tasks: Selecting a location for the CM9700-CC1 in a standard EIA rack Mounting the CM9700-CC1 Connecting the CM9700-CC1 Powering on the CM9700-CC1 To perform each of the above tasks, refer to the sections that follow. SELECTING A LOCATION FOR THE CM9700-CC1 The CM9700-CC1 is designed to be mounted into a standard 19-inch (48.26 cm) EIA rack. When selecting a location in a r
Summary of the content on the page No. 16
(8) SCREWS, REAR MOUNTING 10-32 X 0.375-INCH SUPPORT RAIL FLAT HEAD FRONT MOUNTING SUPPORT RAIL (6) SCREWS, 8-32 X 0.375-INCH PAN HEAD WITH WASHERS RACK (4) SCREWS 10-32 X 0.375-INCH FLAT HEAD BRACKET (SIDE VIEW) CM9700-CC1 (6) SCREWS, 8-32 X 0.250-INCH PAN HEAD (3 EACH SIDE) (4) SCREWS, 10-32 X 0.750-INCH PHILLIPS, PAN HEAD WITH WASHERS SLOTTED HOLES TAPERED ENDS TOWARDS FRONT TOWARDS REAR OF UNIT OF UNIT Figure 2. Mounting the CM9700-CC1 C1572M (9/05) 15
Summary of the content on the page No. 17
CONNECTING THE CM9700-CC1 System 9760 devices and other equipment connect to the rear panel of the CM9700-CC1 (refer to Figure 3). CM9700-MGR PC VGA MONITOR CM9700-CC1 36 28 20 12 35 27 19 11 RS-422 SERCOM PORT 34 26 18 10 CONNECTIONS 33 25 17 9 32 24 16 8 POWER CORD 31 23 15 7 30 22 14 6 PRINTER COM1 COM2 29 21 13 5 PS/2 KEYBOARD Figure 3. CM9700-CC1 Connections As illustrated in Figure 3, CM9700-CC1 connections include the following: CM9700-MGR PC (RS-232 serial
Summary of the content on the page No. 18
TO CM9700-CC1 TO CM9700-MGR PC COM 1/COM 2 PORT COM 1/COM 2 PORT PIN 3 (TX) PIN 2 (RX) PIN 2 (RX) PIN 3 (TX) PIN 5 (GND) PIN 5 (GND) NULL MODEM CABLE (RS-232) DB9 FEMALE DB9 FEMALE Figure 4. CM9700-MGR PC to CM9700-CC1 Null Modem Cable Connections Connecting a VGA Monitor to the CM9700-CC1 When connected to the CM9700-CC1, a VGA monitor displays the CM9700-CC1 diagnostic screen (refer to Monitoring CM9700-CC1 Functions in the System Diagnostics section for detailed information about the CM9700
Summary of the content on the page No. 19
Using the System 9760 Port Assignment Table The System 9760 port assignment table, titled “System 9760 Factory Default Port Settings,” lists the CM9700-CC1 port numbers (1-36) and each device that has been assigned to a particular CM9700-CC1 port and configured for your system at the factory. Figure 5 illustrates a sample port assignment table for a system containing a CM9700-MGR (System Manager) PC, three CM9760-MXBs, and one CM9760-KBD. Note that the port assignment table for your system wil
Summary of the content on the page No. 20
In the sample port assignment table shown in Figure 5, note the following: CM9700-CC1 port 1 (COM 1) is assigned and configured for the System Manager; therefore, the System Manager PC should be connected to COM 1 on the CM9700-CC1. NOTE: For all systems configured at the factory, COM 1 is always configured as the port to be used with the System Manager PC. CM9700-CC1 port 2 (COM 2) is not assigned or configured for any device. Because CM9700-CC1 ports 3 and 4 are not present on the CM9700-C