Pelco C1043M-A user manual

User manual for the device Pelco C1043M-A

Device: Pelco C1043M-A
Category: Home Security System
Manufacturer: Pelco
Size: 0.31 MB
Added : 10/6/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Pelco C1043M-A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Pelco C1043M-A.

For your convenience

If looking through the Pelco C1043M-A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Pelco C1043M-A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Pelco C1043M-A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Pelco C1043M-A User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Pelco C1043M-A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Pelco C1043M-A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
ICI3000P
Inter-Check Point-Of-Sale
Monitoring System
Installation/Operation Manual
C1043M-A (2/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827

Summary of the content on the page No. 2

TABLE OF CONTENTS Section Page 1.0 WARNINGS ....................................................................................................................................... 1 2.0 SCOPE .............................................................................................................................................. 2 2.1 DESCRIPTION ........................................................................................................................ 2 3.0 INSTALLATION .......

Summary of the content on the page No. 3

6.0 HOT KEY SUMMARY LIST ............................................................................................................. 21 7.0 TROUBLESHOOTING .................................................................................................................... 23 8.0 POWER-UP PROCEDURE FOR THE ICI3000P ............................................................................ 24 9.0 SPECIFICATIONS ...................................................................................

Summary of the content on the page No. 4

(This page intentionally left blank.) iv Pelco Manual C1043M-A (2/96)

Summary of the content on the page No. 5

INSTALLATION/OPERATION MANUAL ® ICI3000P INTER-CHECK POINT-OF- SALE MONITORING SYSTEM 1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1.Installation and servicing should only be done by 4. Only use replacement parts recommended by qualified service personnel and conform to all PELCO. Local codes. 5.After replacement/repair of this unit’s electrical 2. Unless the unit is specifically marked as a NEMA components, conduct a resistance measurem

Summary of the content on the page No. 6

2.0 SCOPE 2.1 DESCRIPTION The information contained within this manual covers These units are point-of-sale (POS) monitoring devices the installation and operation of the Inter-Check capable of monitoring up to sixteen (16) POS termi- ICI3000P cash register interface system. Installation nals simultaneously with up to thirty-two (32) units in- should be in accordance with all applicable local and stalled at one time. Standard features include: fifteen national electric codes, using approved ma

Summary of the content on the page No. 7

3.0 INSTALLATION 7. To verify communication between your ICI1000PIM and the ICI3000P, press [I] on the 3.1 SETTING UP ICI1000PIM keyboard and the following will be displayed: PARAMETERS AND BENCH TESTING Poll initialized! Reg. polled = 1 1 Reg. answer! NOTE: Please familiarize yourself with the Reg. polled = 2 2 No reg. answer! information in this manual prior to installation Reg. polled = 3 3 No reg. answer! etc. and operation. Contact the customer's register dealer/installer pr

Summary of the content on the page No. 8

3.2 ICI3000WK INSTALLATION NOTE: Do not mount the Inter-Check unit until all connections are made and program- 1. Install an 18 AWG, 3-conductor shielded cable be- ming is complete. Video adjustments on the tween each RJ14 phone jack at each cash register. underside of the unit may need to be accessible Refer to Figure 2 for appropriate wiring configu- during initial setup. ration. NOTE: Do not power up the ICI3000P unit until all other connections have been made. Use only the transformer suppl

Summary of the content on the page No. 9

3.3 ICI3008/ICI3016 INSTALLATION 0000 1000 where 0 = ON and 1 = OFF (refer to Figure 8). Refer to Figure 1 for a typical ICI3000P configuration. 6. Connect the desired alarm outputs to any peripheral 1. Connect the 9-pin switcher interface cable (supplied equipment requiring a normally open contact. (Refer with the ICI3008/ICI3016 switcher) into the port to Figure 5 for pin assignment information.) labeled “RS 232” of the ICI3000P. 7. Connect an “IBM AT” compatible keyboard into the 2. Connect

Summary of the content on the page No. 10

12 34 567 8 1 2 3 4 5 6 7 8 O PE N OPEN - DI P S WI T CH DE S CRI P T I ON- Swi t c h # F unc t i on 1 Bank addr es s Bank Address 2 Bank addr es s Bank Address 3 Bank addr es s Bank Address 4 Bank addr es s Bank Address 5 l oop Loop Select se l e c t 6 baud Baud Rate Select r a t e se l e ct 7 NC NC 8 NC NC Co v e r NOTE: mu s t Cover must be removed to access this dip switch. beremov ed t o ac c e s s t his DI P S wi t c h * Loop = 0 CAMERAS 16- 31 Addr es s = 0001 VI D E O O UT 16 1 5 14 13 1

Summary of the content on the page No. 11

3.3.1 Alarm Pin-out Configuration For detailed 25-pin and 9-pin alarm pin-out configura- tion information, see Figure 5 below. 25-PIN CONNECTOR FOR ICI3016 9-PIN CONNECTOR FOR ICI3008 5 4 3 2 1 1 13 9 8 7 6 25 14 Pin # Alarm Output Pin # Alarm Output 1Alarm Output 1 1Alarm Output 5 2Alarm Output 2 2Alarm Output 7 3Alarm Output 3 3Alarm Output 6 4Alarm Output 4 4Alarm Output 8 5Alarm Output 5 5Alarm Output 1 6Alarm Output 6 6Alarm Output 3 7Alarm Output 7 7Alarm

Summary of the content on the page No. 12

3.4 EXTERNAL VIDEO ADJUSTMENTS 5. Adjust the video GAIN of the monitor by adjusting There are five potentiometer adjustments located on the the potentiometer labeled “G”. This should be turned bottom of the Inter-Check unit. These video text ad- all the way down for normal application. justments are for fine tuning only. Major adjustments should be done through the operating software. Use a 6. Use the two DIP switches labeled "C" to adjust the small tipped, nonmetallic screwdriver for adjusting

Summary of the content on the page No. 13

4.0 PROGRAMMING 4.1 REGISTER 1 OR 2 SELECT To enter the SELECT MENU press enter. The following This menu allows you to manually display the transaction menu will be displayed on monitor: data from a specific register on either Screen 1 (the left- hand side of the monitor) or Screen 2 (the right-hand side of the monitor). (See Figure 7.) To enter this menu, press [1]. The monitor will display: Screen 1 or 2? SELECT MENU Select the screen (1 or 2) on which you want your register 1. Register #

Summary of the content on the page No. 14

4.2.1 Operator Selection Using • Press [3] to select internal synchronization (no the Hot Key F2 video). To select a specific operator for monitoring while in the •Pressing F9 will enable you to select an external monitoring mode: camera from PELCO’s ICI3008/ICI3016 Inter- Check switchers. 1. Press [F2] After pressing F9, the following prompt will be displayed: 2. Select appropriate Screen # (no prompt is displayed): Enter select # Pressing [1] selects Screen 1 Pressing [2] selects Sc

Summary of the content on the page No. 15

4.6 AUTO CAMERA SEARCH ON/OFF 4.8 SYSTEM PROGRAM When enabled, this feature monitors your camera This menu is used for programming text displays; system’s sync generation. If your monitoring camera communication and printer parameters; clock features; loses power or is disconnected, the system will auto- camera selections and alarm dwell time. matically switch to the next camera for synchroniza- tion. If an active video is not detected, the system will To enter the System Menu, Press [8]. The

Summary of the content on the page No. 16

4.8.2 Number of Lines for Small Using the cursor control keys, move the block to the Screens 1 and 2 desired position on the monitor. Press [ENTER] to save. This feature enables you to select the number of data lines NOTE: Overlapping the two screens will result displayed on each screen. The difference between the in “clipping” of the displayed text. “small” and “large” screens is that you may reduce the number of lines displayed on the small screen, while the 4.8.4 Large Screen Position 1 or 2

Summary of the content on the page No. 17

4.8.6 Channel Program Menu Exception Follow Alarm Time This option is used to set the length of time the 4.8.6.1 Partyline Inter-Check unit will dwell on an exception when using the Exception Follow or Hot Key E. When Press [6]. The following prompt will be displayed: this option is selected, the video screen will dis- CHANNEL PROGRAM MENU play: 4. Group Poll List 5. Exception Follow Alarm Time Alarm Dwell = 10 6. Group Select Enter Alarm Dwell Time 0 - 255 4.8.6.2 Channel Program Menu Group

Summary of the content on the page No. 18

4.8.7 Printer Parameters 4.8.9 External Camera Select From this menu the baud rate for the auxiliary output port This feature selects the screen (1 or 2) to be used for may be adjusted to communicate with an optional serial controlling the Inter-Check switcher. The selected screen printer. The Inter-Check defaults to 9600 baud. will have an “S” displayed at the bottom. To edit the baud rate, press [7]. The following prompt • To change the settings, press [9]. The monitor will will appear: di

Summary of the content on the page No. 19

4.8.10 Shadow List Programming Example 1: Shadow List This list tells the 8- or 16-position Inter-Check Switcher REG CAM DWL which camera and POS terminal are linked together. It is 1. 115 also used to program sequential video switching. The [S] 2. 216 hotkey is used to turn switcher sequencing on and off. 3. 324 4. 462 Press [0]. A long list of numbers will scroll up the screen. 5. 5 9 The following prompt will appear: 30. 30 30 During sequencing, with the above parameters set, the 31. 31 31 f

Summary of the content on the page No. 20

4.9 EXCEPTIONS Exceptions are cash register transactions of special interest that can be programmed into the ICI3000P units. Typical transactions are VOID, REFUND, CASH PAID OUT and NO SALE. These types of transactions can then be used to alarm your VCR or other alarmable device for video recording. Exceptions can also be printed out on an external serial printer for immediate hard-copy evidence. NOTE: Exceptions can only be displayed on screen #2. Therefore, you cannot monitor a register or op


Alternative user manuals
# User manual Category Download
1 Pelco ENDURA WS5000 User manual Home Security System 566
2 Pelco Kbd300 User manual Home Security System 105
3 Pelco 12VA6-13 User manual Home Security System 2
4 Pelco Dx8000 User manual Home Security System 12
5 Pelco 13VA1-3 User manual Home Security System 0
6 Pelco 12VD4-10 User manual Home Security System 0
7 Pelco ESPRIT ES30PC User manual Home Security System 22
8 Pelco 13VA2.5-6 User manual Home Security System 0
9 Pelco 12VD6-13 User manual Home Security System 0
10 Pelco CAMCLOSURE C2410M-G User manual Home Security System 0
11 Pelco 13VA2.8-12 User manual Home Security System 1
12 Pelco 1.6 User manual Home Security System 1
13 Pelco 13VA3-8 User manual Home Security System 0
14 Pelco ESPRIT ES31PC User manual Home Security System 12
15 Pelco 13VA5-40 User manual Home Security System 0
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9