Linear REMOTE ACCESS SOFTWARE DVS-2400 user manual

User manual for the device Linear REMOTE ACCESS SOFTWARE DVS-2400

Device: Linear REMOTE ACCESS SOFTWARE DVS-2400
Category: Home Security System
Manufacturer: Linear
Size: 2.4 MB
Added : 10/29/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Linear REMOTE ACCESS SOFTWARE DVS-2400. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Linear REMOTE ACCESS SOFTWARE DVS-2400.

For your convenience

If looking through the Linear REMOTE ACCESS SOFTWARE DVS-2400 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Linear REMOTE ACCESS SOFTWARE DVS-2400 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Linear REMOTE ACCESS SOFTWARE DVS-2400 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Linear REMOTE ACCESS SOFTWARE DVS-2400 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Linear REMOTE ACCESS SOFTWARE DVS-2400 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Linear REMOTE ACCESS SOFTWARE DVS-2400. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PRINTER’S INSTRUCTIONS:
INSTR,DVS-2400 - LINEAR P/N: 212734 H - INK: BLACK - MATERIAL: 20 LB. MEAD BOND WITH 80 LB. WHITE COATED COVER - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM FOLD - BINDING: SADDLE-STITCH
SECURITY
SUPERVISED WIRELESS
SECURITY CONSOLE
Installation & Programming Instructions
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com

Summary of the content on the page No. 2

INTRODUCTION CONGRATULATIONS for selecting Linear’s DVS-2400 Security System. The DVS-2400 Console incorporates many advanced and sophisticated features. The system can be expanded and customized to fi t the installation’s specifi c needs. The DVS-2400 Console and its accessories are designed and manufactured by the oldest wireless security company in North America. You can look ahead to many years of reliable service with this Console and its accessories. Many insurance companies offer disc

Summary of the content on the page No. 3

TABLE OF CONTENTS 1. THE DVS-2400 SECURITY SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 12. ADVANCED PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 CONSOLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CHANGING A SENSORS SUPERVISION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 DOOR/WINDOW SENSORS . . . . . .

Summary of the content on the page No. 4

1. THE DVS-2400 SECURITY SYSTEM DXT-41 & DXT-42 DXT-21 & DXT-23 REMOTES REMOTES † DXT-61 REMOTE † DVS-2400 DXS-10 CONSOLE WIRELESS DXS-62A KEYPAD REMOTE DXS-73 SMOKE DETECTOR † NOTE: These accessories are not listed by UL. DXS-31 DXS-32 MINI DXS-91 GLASS DXS-81 DXS-54 DOOR/WINDOW DOOR/WINDOW BREAK DETECTOR † BILL TRAP † PIR SENSOR SENSOR The Console has 24-hour capabilities that are always ready CONSOLE to operate, even when the Console is disarmed. They can be The DVS-2400 Console is the hea

Summary of the content on the page No. 5

DOOR/WINDOW SENSORS PANIC BUTTONS The DXS-31 and DXS-32 sensors monitor doors and windows. The DXT-21, DXS-21 single-button, and DXT-23, DXS-23 two-button They send radio signals to the Console. One type of signal is sent transmitters can be used as portable “panic buttons”. Pressing the when the door or window is opened, and a different type of signal front or top button on the DXT-21 or DXS-21 at any time will trigger is sent when the door or window is closed. If the Console is armed, the e

Summary of the content on the page No. 6

2. SECURITY SYSTEM FLOOR PLAN EXAMPLE SYSTEM ✦ The example shows a typical DVS-2400 system. ✦ Any or all of the accessories shown can be used. ✦ A total of 24 sensors can be used with each Console. DESIGN THE INSTALLATION 1. Draw a fl oor plan for the installation. 2. Consider the security needs of the premises. 3. Determine which doors and windows are vulnerable to intrusion. 4. Figure which interior areas an intruder might go to if unlawful entrance is gained. 5. Indicate locations for door/

Summary of the content on the page No. 7

3. TYPICAL SYSTEM SENSORS DOOR/WINDOW SENSOR ✦ Sensor mounts on door or window with adjacent magnet. ✦ Opening door or window moves magnet away, triggering sensor. ✦ Pressing the case causes sensor to send a test signal. ✦ Jumper inside for INSTANT or DELAYED alarm setting. ✦ Press the case for testing, the red transmit light shows that battery is in good condition. ✦ Internal lithium batteries are monitored by the Console. ✦ Sends hourly status reports to the Console. ✦ Up to 3 years batt

Summary of the content on the page No. 8

4. CONSOLE FEATURES 3 MODE INDICATORS ★ Specifi c indicator will light showing the mode the Console is in. 5 ★ HOME indicator will blink during Secure Exit and Home Instant modes. ★ AWAY indicator will blink during the exit delay in the Away Mode. 4 4 CONSOLE STATUS INDICATORS ★ Shows the current status of the Console. 3 POWER LIGHT ★ Glows when AC power is on. ★ Blinks when AC power is off and backup battery is installed. 2 ★ Blinks when the backup battery is low, recharging or missing. ★ Off wh

Summary of the content on the page No. 9

13 14 16 15 12 11 10 17 22 18 21 19 20 10 AUXILIARY FUSE 19 RADIO TEST POINTS ★ Type 2AG, 1-amp fuse. ★ Used to monitor the Console's radio receiver during troubleshooting. ★ Protects the external relay output when used with wet contacts (12 VDC ★ Provides connection for an audio amplifi er to listen to the receiver's output. switched out). ★ Helpful to determine sources of radio interference. ★ Fuse will blow when load exceeds 1 amp. 20 MICROPHONE (WITH MODEL VB-2 INSTALLED ONLY) ✎ WARNING: For

Summary of the content on the page No. 10

5. CONSOLE INSTALLATION CONSOLE LOCATION ✎ NOTE: Wireless sensor signals must be able to reach the Console. ✔ Try to centrally locate the Console. ✔ Keep Console away from large metal USE A PAPER appliances. CLIP TO REMOVE THE CLEAR ✔ Maximum recommended sensor range is 400 DISPLAY WINDOW feet (system tested at 1000 feet). ✎ NOTE: If you don't use the Wireless Keypad, the Console should be easily accessible to the usual entrance. ✔ When the Console is set in the Away Mode, REMOVE CASE t

Summary of the content on the page No. 11

EXTERNAL CONSOLE SPEAKER CONNECTION ✦ An external console speaker sounds system tones EXTERNAL and alerts occupants with a loud siren during alarm. CONSOLE SPEAKER ✦ With the VB-2 module installed, the Central Station can talk to the occupants through the external console speaker. ✦ Use an 8-ohm, 10 watt minimum rated speaker. Do not use a horn/siren with a built-in siren driver. LINEAR SECURITY CONSOLE MODEL DVS-2400 MAIN TERMINAL BLOCK ✦ Up to two 8-ohm speakers can be used with each AC C

Summary of the content on the page No. 12

R T R1 T1 TELEPHONE LINE CONNECTION TELEPHONE ✦ Connect the Console to the telephone line if the TERMINAL LINEAR SECURITY CONSOLE MODEL DVS-2400 BLOCK system is monitored, requires 2-way audio, or requires telephone remote command. TELEPHONE TERMINAL BLOCK SEIZED RING TIP ✦ Telephone RING & TIP terminals are for connection SEIZED TIP RING to the incoming telephone line. TO LOCAL TO PHONE PHONES LINE OPTIONAL ✦ Seized telephone ring & tip are for connection VOICE MODULE MODEL: VB-2 to local

Summary of the content on the page No. 13

CONSOLE POWER CONNECTION ✦ The Console is powered by a low voltage plug-in LINEAR SECURITY CONSOLE MODEL DVS-2400 MAIN TERMINAL BLOCK transformer. AC AC ✦ Use up to 25 feet of 20 AWG or larger EXT. SPKR PLUG-IN TRANSFORMER (-) two-conductor wire to connect the transformer to 16 VAC, 28 VA H/A - MAIN H/A + the Console. TERMINAL BLOCK OPTIONAL RELAY N.O. VOICE MODULE RELAY DRY 1. Route the power wires from the plug-in transformer MODEL: VB-2 to the Console. 2. Connect the wires to the transfor

Summary of the content on the page No. 14

6. BASIC CONSOLE PROGRAMMING ✦ In a new installation, when power is fi rst applied the system's master user code is “1234”. CREATE THE MASTER USER CODE ✎ NOTE: Local programming must be entered on ENTERING SETTING A the Console's keypad, not on a wireless remote SETUP NEW MASTER keypad. MODE USER CODE 1. Press (clears keypad if any other keys have START IN OFF START IN SETUP been pressed). CLEARS 2. Place the Console in Test Mode (enter 1234 and KEYPAD PROGRAMMING press TEST. STEP #99 ✴ A

Summary of the content on the page No. 15

PROGRAMMING DIFFERENT SENSOR TYPES ✦ Follow the instructions on the previous page to select a sensor number to program the sensor into. ✎ NOTE: A sensor can be programmed into more than one location. Be sure to choose an UNUSED sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. ✦ To add DXS-10 wireless keypads, press and hold the keypad's key until programmed into the Console. ✦ For DXS-31 and DXS-32 door/window sen

Summary of the content on the page No. 16

7. BASIC SENSOR INSTALLATION ✦ Each accessory sensor is packaged with its own set of installation instructions specifi c to the model of sensor. ✦ Refer to the sensor's instructions for details on installing, operating, and testing of the sensor. FROM TOP OF CASE TWIST SCREWDRIVER BETWEEN CASE HALVES UNTIL IT ✦ Following are basic instructions for installing two POPS OPEN popular DVS-2400 accessories: The Model DXS-10 Wireless Remote Keypad and the Model DXS-31 or DXS-32 Door/Window Transmi

Summary of the content on the page No. 17

EXAMPLE INSTALLATION (WITH DXS-31 SHOWN) DXS-31 & DXS-32 DOOR/WINDOW SENSORS ✦ The DXS-31 and DXS-32 sensors can be used LEFT OPENING DOOR SLIDING WINDOW to monitor doors, windows, cabinets, crawl space TRANSMITTER MOUNTED ON doors, gates, freezer doors, and many other moving DOOR JAMB MAGNET MOUNTED ON WINDOW FRAME objects that could be used for intrusion or need to (NOTE: SMALL END OF TRANSMITTER UP) be monitored. MAGNET MOUNTED ✦ A built-in magnetic switch triggers the sensor when ON DOOR

Summary of the content on the page No. 18

8. CUSTOMIZING THE CONSOLE USE SENSOR ✦ The Console can be customized for the specifi c LABELS PROVIDED installation. ✦ A label sheet with sensor location names is provided with the Console. ✦ Labeling the sensors allows quick and easy identifi cation of where a door or window is open, WRITE IN SPECIAL LOCATIONS ON where any alarms have occurred, where a sensor BLANK LABELS with a low battery is, or where a sensor with trouble is. BEND TABS DOWN LABELING THE SENSORS AND INSERT IN SLOTS 1.

Summary of the content on the page No. 19

9. CONSOLE OPERATING MODES OFF MODE ✦ Use this mode to disarm the burglary portion of the system. ✦ Switching to Off Mode stops any alarms in progress. OFF MODE ✦ The 24-hour functions are still active in Off Mode and can be triggered by pressing the FIRE or START HERE EMERGENCY button. (OPTIONAL) 1. Switch to Off Mode by entering the user code, and pressing OFF. ✴ When the system is disarmed to Off Mode, the Console will sound one “Gong”. YOUR ✴ If an alarm has occurred, multiple Beeps w

Summary of the content on the page No. 20

HOME MODE MANUAL BYPASSING OF SENSORS ✦ Use this mode when sleeping or when anyone is ✦ Manual bypassing of sensors in the Home Mode staying inside. allows arming of the system at night with open windows, while still having perimeter protection with ✦ Home Mode causes an instant alarm when any other closed doors and windows. perimeter sensor is triggered. 1. The Console will resist arming with open door or ✦ Home Mode causes a delayed alarm when any exit/ window sensors. entry sensor is tri


Alternative user manuals
# User manual Category Download
1 Linear CCM-2 User manual Home Security System 0
2 Linear DF-16/EC User manual Home Security System 1
3 Linear CCM-1A User manual Home Security System 0
4 Linear DXS-54 User manual Home Security System 0
5 Linear AM-KPI User manual Home Security System 3
6 Linear DF-31/EC User manual Home Security System 1
7 Linear CCM-2A User manual Home Security System 0
8 Linear AL-1 User manual Home Security System 0
9 Linear DF-54/EC User manual Home Security System 0
10 Linear DXS-62 User manual Home Security System 0
11 Linear DUAL 824 User manual Home Security System 2
12 Linear DXS-63 User manual Home Security System 0
13 Linear DXS-54/EC User manual Home Security System 0
14 Linear DXS-65 User manual Home Security System 1
15 Linear DXT-42 User manual Home Security System 3
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9