Summary of the content on the page No. 1
Black 0001
1
SUPERVISED WIRELESS
SECURITY CONSOLE
Installation & Programming Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
0001 Black
Summary of the content on the page No. 2
Black 0002 INTRODUCTION CONGRATULATIONS for selecting Linear’s DVS-1200 Security System. The DVS-1200 Console incorporates many advanced and sophisticated features. The system can be expanded and customized to fit the installation’s specific needs. The DVS-1200 Console and its accessories are designed and manufactured by the oldest wireless security company in North America. You can look ahead to many years of reliable service with this Console and its accessories. Many insurance companies offer
Summary of the content on the page No. 3
Black 0003 TABLE OF CONTENTS 1. THE DVS-1200 SECURITY SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . 2 12. ADVANCED PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 CONSOLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SETUP MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Summary of the content on the page No. 4
Black 0004 1. THE DVS-1200 SECURITY SYSTEM DXT-61 DXT-21 & DXT-23 REMOTE † DXT-41 & DXT-42 REMOTES † REMOTES DVS-1200 DXS-10 CONSOLE WIRELESS KEYPAD DXS-72 DXS-71 SMOKE DETECTOR SMOKE DETECTOR † NOTE: These accessories are not listed by UL. DXS-31 DXS-91 GLASS DXS-81 DXS-54 DOOR/WINDOW BREAK DETECTOR † BILL TRAP † PIR SENSOR provides three exciting features: 2-way audio monitoring CONSOLE capability at the Central Station through the communicator, The DVS-1200 Console is the heart of the system
Summary of the content on the page No. 5
Black 0005 DOOR/WINDOW SENSORS PANIC BUTTONS The DXS-31 sensors monitor doors and windows. They send The DXT-21 and DXT-23 transmitters can be used as portable radio signals to the Console. One type of signal is sent when “panic buttons”. Pressing the front or top button on the DXT-21 the door or window is opened, and a different type of signal is at any time will trigger the emergency siren. Pressing both sent when the door or window is closed. If the Console is armed, front buttons simultaneou
Summary of the content on the page No. 6
Black 0006 2. SECURITY SYSTEM FLOOR PLAN EXAMPLE SYSTEM ◆ The example shows a typical DVS-1200 system. ◆ Any or all of the accessories shown can be used. ◆ A total of 12 sensors (including keypads) can be used with each Console. DESIGN THE INSTALLATION Create a floor plan of the installation. Consider the security needs of the premises. Determine which doors and windows are vulnerable to intrusion. Figure which interior areas an intruder might go to if unlawful entrance is gained. Indicate locat
Summary of the content on the page No. 7
Black 0007 3. TYPICAL SYSTEM SENSORS DOOR/WINDOW SENSOR ◆ Sensor mounts on door or window with adjacent magnet. ◆ Opening door or window moves magnet away, triggering sensor. ◆ Pressing the case causes sensor to send a test signal. ◆ Jumper inside for INSTANT or DELAYED alarm setting. ◆ Press the case for testing, the red transmit light shows that battery is in good condition. ◆ Internal lithium batteries are monitored by the Console. ◆ Sends hourly status reports to the Console. ◆ Up to 3 years
Summary of the content on the page No. 8
Black 0008 4. CONSOLE FEATURES 3 MODE INDICATORS ★ Specific indicator will light showing the mode the Console is in. 5 ★ HOME indicator will blink during secure exit and home instant modes. ★ AWAY indicator will blink during the exit delay in the Away Mode. 4 4 CONSOLE STATUS INDICATORS ★ Show the current status of the Console. 3 POWER LIGHT ★ Glows when AC power is on. ★ Dims when AC power is off and backup battery is installed. ★ Blinks when the backup battery is low, recharging or missing. 2
Summary of the content on the page No. 9
Black 0009 13 14 16 15 12 11 10 17 22 18 21 19 20 10 AUXILIARY FUSE 19 RADIO TEST POINTS ★ Type 2AG, 1-amp fuse. ★ Used to monitor the Console’s radio receiver during troubleshooting. ★ Protects the external relay output when used with wet contacts (12 VDC ★ Provides connection for an audio amplifier to listen to the receiver’s output. ★ switched out). Helpful to determine sources of radio interference. ★ Fuse will blow when load exceeds 1 amp. 20 MICROPHONE (WITH MODEL VB-2 INSTALLED ONLY) ✍ WA
Summary of the content on the page No. 10
Black 0010 5. CONSOLE INSTALLATION CONSOLE LOCATION ✍ NOTE: Sensor signals must be able to reach the Console. ✔ Try to centrally locate the Console. ✔ Keep Console away from large metal USE A PAPER appliances. CLIP TO REMOVE ✔ Maximum recommended sensor range is THE CLEAR DISPLAY WINDOW 400 feet (system tested at 1000 feet). ✍ NOTE: If you don’t use the Wireless Keypad, the Console should be easily accessible to the usual entrance. ✔ When the Console is set in the Away Mode, the user has 30 se
Summary of the content on the page No. 11
Black 0011 EXTERNAL CONSOLE SPEAKER CONNECTION (OPTIONAL) ◆ An external console speaker sounds system EXTERNAL CONSOLE tones and alerts occupants with a loud siren during alarm. SPEAKER ◆ With the VB-2 module installed, the Central Station can talk to the occupants through the external console speaker. ◆ Use an 8-ohm, 10 watt minimum rated LINEAR SECURITY CONSOLE MODEL DVS-1200 speaker. Do not use a horn/siren with a MAIN TERMINAL BLOCK AC built-in siren driver. AC ANNUNCIATOR EXT. SPKR(S) EXT.
Summary of the content on the page No. 12
R T R1 T1 Black 0012 TELEPHONE LINE CONNECTION (OPTIONAL) TELEPHONE TERMINAL ◆ Connect the Console to the telephone line if LINEAR SECURITY CONSOLE MODEL DVS-1200 BLOCK the system is monitored, requires 2-way TELEPHONE TERMINAL BLOCK audio, or requires telephone remote command. SEIZED RING TIP SEIZED TIP RING ◆ Telephone ring & tip terminals are for TO LOCAL TO PHONE connection to the incoming telephone line. PHONES LINE OPTIONAL ◆ Seized telephone ring & tip are for connection VOICE MODULE MODE
Summary of the content on the page No. 13
Black 0013 CONSOLE POWER CONNECTION LINEAR SECURITY CONSOLE MODEL DVS-1200 ◆ The Console is powered by a low voltage MAIN TERMINAL BLOCK plug-in transformer. AC AC ◆ Use up to 25 feet of 20 AWG or larger EXT. SPKR PLUG-IN TRANSFORMER (-) two-conductor wire to connect the transformer 16 VAC, 28 VA H/A - MAIN to the Console. H/A + TERMINAL BLOCK OPTIONAL RELAY N.O. VOICE MODULE RELAY DRY Route the power wires from the plug-in MODEL: VB-4 transformer to the Console. Connect the wires to the transfo
Summary of the content on the page No. 14
Black 0014 6. BASIC CONSOLE PROGRAMMING ◆ In a new installation, when power is first applied, the Console’s master user code is “1234”. CHANGE THE MASTER USER CODE ✍ NOTE: Local programming must be entered on the Console’s keypad, not on a wireless remote keypad. ENTERING SETTING A SETUP NEW MASTER Press [ ] (clears keypad if any other keys * MODE USER CODE have been pressed). START IN OFF START IN SETUP Place the Console in Test Mode (enter 1234 and press [ ]). CLEARS TEST KEYPAD PROGRAMMING ❇
Summary of the content on the page No. 15
Black 0015 PROGRAMMING DIFFERENT SENSOR TYPES ◆ Follow the instructions on the previous page to select a sensor number to program the sensor into. ✍ NOTE: A sensor can be programmed into more than one location. Be sure to choose an unused sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. To add DXS-10 wireless keypads, press and hold the keypad’s [ ] key until programmed * into the Console. ✍ IMPORTANT NOTE: The DXS-31 do
Summary of the content on the page No. 16
Black 0016 7. BASIC SENSOR INSTALLATION ◆ Each accessory sensor is packaged with its own set of installation instructions specific to the model of sensor. FROM TOP OF CASE TWIST SCREWDRIVER BETWEEN ◆ Refer to the sensor’s instructions for details on CASE HALVES UNTIL IT POPS OPEN installing, operating, and testing of the sensor. ◆ Following are basic instructions for installing two popular DVS-1200 accessories: The Model DXS-10 Wireless Remote Keypad and the Model DXS-31 Door/Window Transmitter.
Summary of the content on the page No. 17
Black 0017 EXAMPLE INSTALLATIONS DXS-31 DOOR/WINDOW SENSORS LEFT OPENING DOOR SLIDING WINDOW ◆ The DXS-31 sensors can be used to monitor TRANSMITTER MOUNTED ON doors, windows, cabinets, crawl space doors, DOOR JAMB MAGNET MOUNTED ON WINDOW FRAME gates, freezer doors, and many other moving (NOTE: SMALL END objects that could be used for intrusion or OF TRANSMITTER UP) need to be monitored. MAGNET MOUNTED ON DOOR TRANSMITTER ◆ A built-in magnetic switch triggers the sensor MOUNTED ON WINDOW SILL w
Summary of the content on the page No. 18
Black 0018 8. CUSTOMIZING THE CONSOLE ◆ The Console can be customized for the USE SENSOR specific installation. LABELS PROVIDED ◆ A label sheet with sensor location names is provided with the Console. ◆ Labeling the sensors allows quick and easy identification of where any alarms have occurred, where a sensor with a low battery is, WRITE IN SPECIAL LOCATIONS ON where a sensor with radio trouble is, etc. BLANK LABELS LABELING THE SENSORS Use a paper clip to remove the clear display BEND TABS DOW
Summary of the content on the page No. 19
Black 0019 9. CONSOLE OPERATING MODES OFF MODE ◆ Use this mode to disarm the burglary portion of the system. OFF MODE ◆ Switching to Off Mode stops any alarms in progress. START HERE ◆ The 24-hour functions are still active in Off Mode and can be triggered by pressing the (OPTIONAL) [ ] or [ ] button. FIRE EMERGENCY Switch to Off Mode by entering the user code, and pressing [ ]. OFF YOUR ❇ When the system is disarmed to Off Mode, the USER Console will sound one “Gong”. CODE ❇ If an alarm has oc
Summary of the content on the page No. 20
Black 0020 HOME MODE MANUAL BYPASSING OF SENSORS ◆ Use this mode when sleeping or when anyone ◆ Manual bypassing of sensors in the Home is staying inside. Mode allows arming of the system at night with open windows, while still having ◆ Home Mode causes an instant alarm when perimeter protection with other closed doors any perimeter sensor is triggered. and windows. ◆ Home Mode causes a delayed alarm when any ◆ The Console will resist arming with open door exit/entry sensor is triggered (except