Liebert Autochangeover Controllers AC4 user manual

User manual for the device Liebert Autochangeover Controllers AC4

Device: Liebert Autochangeover Controllers AC4
Category: Home Security System
Manufacturer: Liebert
Size: 2.94 MB
Added : 10/29/2013
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert Autochangeover Controllers AC4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert Autochangeover Controllers AC4.

For your convenience

If looking through the Liebert Autochangeover Controllers AC4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert Autochangeover Controllers AC4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert Autochangeover Controllers AC4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert Autochangeover Controllers AC4 User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert Autochangeover Controllers AC4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert Autochangeover Controllers AC4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MONITORING
AC4
USER MANUAL

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Methods of Viewing and Configuring the AC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Data Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.3 Available Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.4 Outside Enclosure Overview . . . . . . . . . .

Summary of the content on the page No. 4

6.0 SILENCE ALARM & BACKUP LOG FILES (SERVICE TERMINAL INTERFACE) 6.1 Silence Alarm (Service Terminal Interface) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 6.2 Back Up Log Files (Service Terminal Interface only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7.0 SYSTEM AND CONTROL OPTIONS 7.1 Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 7.2 S

Summary of the content on the page No. 5

APPENDIX A-SERVICE TERMINAL INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 A.1 Comparison of Functions: LCD and Service Terminal Interface. . . . . . . . . . . . . . . . . . . . . . 49 A.2 Connecting to the Service Terminal Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 A.2.1 Create a Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 A.2

Summary of the content on the page No. 6

FIGURES Figure 1 AC4 enclosure—external features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 2 AC4 enclosure—internal features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 3 Typical Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 4 Example of typical sequence. . . . . .

Summary of the content on the page No. 7

Introduction 1.0 INTRODUCTION The Liebert AC4 is ideal for coordinated control of systems with redundant equipment, such as multiple environmental units or pumps. When the AC4 controller detects an alarm in an operating device, the AC4 enables a standby device and controls the device in alarm as configured, either leaving that device operating or disabling it. The AC4 controller can also balance usage of devices by rotating units through Operating and Standby modes according to a user-defin

Summary of the content on the page No. 8

Introduction 1.4 Outside Enclosure Overview The AC4’s controller board comes in an enclosure that is 2-3/4" deep and has a built-in liquid crystal display (LCD) and a key lock, as shown in Figure 1. The enclosure is made of metal to accommodate secure conduit fittings and protect components against environmental debris. Figure 1 AC4 enclosure—external features LCD for configuration and operation The enclosure has knockouts and access slots on top and Key lock bottom for cables and wires.

Summary of the content on the page No. 9

Introduction 1.5 Typical Configuration Figure 3 shows an example of external devices connected to the AC4’s controller board. There may be up to four devices connected to the four digital inputs and four digital outputs. Remote access is avail- able through the Service Terminal Interface. Figure 3 Typical Configuration DEVICES CONNECTED TO INPUTS & OUTPUTS Zone 1 Devices Device 1 Device 2 Liebert Liebert Challenger Challenger 3000 3000 Zone 2 Devices Device 3 Device 4 RS232 Liebert Liebert H

Summary of the content on the page No. 10

Introduction 1.6 Controller Board Overview The AC4’s controller board has connectors for four digital inputs and four digital outputs, as shown below. The board comes complete with light emitting diodes (LEDs) to display the status of connected devices, a serial communications port, a power connection and other features necessary to control your operation. D - Common Alarm A - Power C - Audible horn B - Audible connectors On/Off switch jumper horn E - Digital output P - 24VAC power stat

Summary of the content on the page No. 11

Introduction Table 1 Controller board components (continued) Item Description For more information, see: One of four output jumpers. Each digital output has a jumper to set the fail-safe position of the output point when 3.2.3: Setting the Digital Output power fails. The OFF position makes the contact Normally I - Digital output Jumpers loss-of-power Open (factory default). The ON position makes the contact 7.6.4: Configure Output for Loss of Normally Closed. jumper Power (“Fail-Safe”) No

Summary of the content on the page No. 12

Introduction 1.7 LED Indicators The AC4’s controller board has LED indicators that show the status of inputs, outputs and the com- mon alarm OUTPUT1 DS56 Output LEDs OUTPUT2 DS54 OUTPUT3 DS63 OUTPUT4 DS61 OUTPUT5 DS60 OUTPUT6 DS62 OUTPUT7 DS55 OUTPUT8 DS57 CTRLLOCK DS59 SENLOCK DS58 CMN ALR DS53 DS52 MOP Status LEDs DS51 F PROG DS48 574 TX 574 RX DS47 485 RX DS78 485 TX DS79 DS69 INPUT1 Input LEDs DS71 INPUT2 INPUT3 DS72 INPUT4 DS70 INPUT5 DS67 INPUT6 DS66 INPUT7 DS65 INPUT8 DS64 Table 2 LED ind

Summary of the content on the page No. 13

Introduction 1.8 Typical Sequence Figure 4 shows a typical sequence of how the AC4 functions after detecting a change in a monitored device. Many responses depend on configuration settings. This example shows what happens when a digital input changes state—assuming the input is defined as alarmable—and when the condition returns to normal. Figure 4 Example of typical sequence RESPONSES TO AN ALARM RETURN-TO-NORMAL SEQUENCE ALARM CONDITION DETECTED RETURN TO NORMAL A device connected to the AC

Summary of the content on the page No. 14

Installation 2.0 INSTALLATION 2.1 Installation Considerations The AC4 must be installed indoors and may be mounted on the surface of a wall or flush-mounted, depending on the user’s application, the location of equipment to be connected and the type of wall the unit will be mounted on. The AC4 should be mounted where it can be easily accessed. On-site personnel would access the unit through the LCD on its front cover or the service terminal connected to the RS232 port. In addition to the comm

Summary of the content on the page No. 15

Installation 2.2 Surface-Mounting the AC4 NOTE Removing the conduit knockouts before mounting the AC4 on the wall will ease installation and prevent strain on the mounting hardware and wall. It is imperative to remove the knockouts if the unit is to be flush-mounted. After determining where to place the unit, check to ensure that you have all the hardware required to install the panel on the surface of a wall. Obtain the needed tools and material. Required tools • Electric drill (if surface i

Summary of the content on the page No. 16

Installation 2.3 Flush-Mounting the AC4 NOTE Removing the conduit knockouts before mounting the AC4 on the wall will ease installation and prevent strain on the mounting hardware and wall. It is imperative to remove the knockouts if the unit is to be flush-mounted. The rectangular access doors on the top and bottom of the AC4 must be reversed so they slide the opposite direction. Leaving the doors as shipped from the factory prevents them from being opened when the panel is flush mounted in

Summary of the content on the page No. 17

Installation 2.4 Connect Power to the AC4 The AC4 requires 24VAC for proper operation. Liebert recommends using the optional Transformer Module manufactured by Liebert or another UL-approved class 2 power unit to obtain proper voltage. If the power unit is not a class 2 circuit, it must be protected with an IEC 5 x 20mm time lag 2A fuse. For information, consult your local dealer, Liebert representative or the Liebert Worldwide Support Group. WARNING ! Check that power is removed from wires

Summary of the content on the page No. 18

Wiring and Connections 3.0 WIRING AND CONNECTIONS CAUTION ! Switch OFF electric power to the AC4 before installing any wiring to the unit or changing input or output connections. The Power On/Off switch is in the top left corner of the unit. 3.1 Wiring Specifications Input and output connections to the AC4 may be made in any order—it is not necessary, for example, to make all input connections before making any output connections. Use copper conductors only for all wiring. Table 4 Wiring spec

Summary of the content on the page No. 19

Wiring and Connections 3.2 Connecting Digital Inputs and Outputs The digital inputs and outputs are found on the lower right side of the AC4’s printed wiring assembly board. This section describes how to connect devices to the AC4’s inputs and outputs. Each input is tied to an output with the same number: • Input 1 is tied to Output 1 (default name: Device_1) • Input 2 is tied to Output 2 (default name: Device_2) • Input 3 is tied to Output 3 (default name: Device_3) • Input 4 is tied to Output

Summary of the content on the page No. 20

Wiring and Connections 3.2.3 Setting the Digital Output Jumpers Digital output jumpers (four) Each digital output has an associated jumper to define its operation when power is interrupted. This puts the AC4 in a fail-safe mode and ensures proper functioning when the board has no power. The AC4 comes from the factory with all digital output jumpers in the OFF position (normally open). The jumper setting for each digital output can be changed to ON (nor- mally closed). The settings are shown


Alternative user manuals
# User manual Category Download
1 Liebert Autochangeover Controllers AC4 User manual Switch 15
2 3Com 1000BASE-T-GBIC User manual Home Security System 0
3 Sony BRCSDP12 User manual Home Security System 3
4 3Com TECHD-0000000122 User manual Home Security System 1
5 Sony SSC-M354 User manual Home Security System 3
6 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
7 Sony SNC-RX SNC-CS50 User manual Home Security System 4
8 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
9 Sony CD-7226 User manual Home Security System 1
10 Sony Ssc-M383 User manual Home Security System 6
11 Sony Snc Df50n User manual Home Security System 1
12 Sony SNC-RX SNC-RZ50 User manual Home Security System 20
13 Sony BLUETOOTH MEX-BT2500 User manual Home Security System 10
14 4XEM IPCAMW40 User manual Home Security System 1
15 ABC Office 24501 User manual Home Security System 0