Honeywell VISTA250BPT/ user manual

User manual for the device Honeywell VISTA250BPT/

Device: Honeywell VISTA250BPT/
Category: Home Security System
Manufacturer: Honeywell
Size: 0.94 MB
Added : 5/26/2014
Number of pages: 80
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell VISTA250BPT/. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell VISTA250BPT/.

For your convenience

If looking through the Honeywell VISTA250BPT/ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell VISTA250BPT/ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell VISTA250BPT/ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell VISTA250BPT/ User manual - Online PDF
Advertisement
« Page 1 of 80 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell VISTA250BPT/ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell VISTA250BPT/. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


V V V VI I I IS S S ST T T TA A A A- - - -1 1 1 12 2 2 28 8 8 8B B B BP P P PT T T T/ / / /
V V V VI I I IS S S ST T T TA A A A- - - -1 1 1 12 2 2 28 8 8 8B B B BP P P PT T T T/ / / /
V VI IS ST TA A- -2 25 50 0B BP PT T/ /
V VI IS ST TA A- -2 25 50 0B BP PT T/ /
V V V VI I I IS S S ST T T TA A A A- - - -2 2 2 25 5 5 50 0 0 0B B B BP P P PT T T T/ / / /
V V V VI I I IS S S ST T T TA A A A- - - -1 1 1 12 2 2 28 8 8 8B B B BP P P PT T T TS S S SI I I IA A A A
V V V VI I I IS

Summary of the content on the page No. 2

Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. Your Honeywell security system is not designed for use with any device that may be attached to your security system's keypad or other communicating bus if Honeywell has not approved such device for use with your security system. Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the v

Summary of the content on the page No. 3

TABLE OF CONTENTS SYSTEM OVERVIEW ....................................5 Common Lobby Operation .......................25 General .......................................................5 How User Codes Affect the Common A Partitioned System ..................................6 Lobby ........................................................26 Zones..........................................................6 CHECKING FOR OPEN ZONES .................27 Fire Protection .............................

Summary of the content on the page No. 4

TESTING THE SYSTEM (TO BE Using the 9 Key ...................................41 CONDUCTED WEEKLY) .........................60 VIEWING ALARM COMPANY Using the 5 TEST Key.........................60 MESSAGES .............................................42 General Information..................................42 Testing Your System ................................60 PANIC KEYS................................................43 FIRE ALARM SYSTEM................................61 (FOR MANU

Summary of the content on the page No. 5

System Overview General Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategically positioned throughout the premises. The system offers you three forms of protection: burglary, fire and emergency. The keypad provides full control of system operation. The system uses microcomputer technology to monitor all protection zones and system status and provides appropriate information for display on the keypad(s) used with the system

Summary of the content on the page No. 6

System Overview (cont’d) A Partitioned System Simply stated, a partitioned system shares one physical alarm system among different users, each with their own requirements. For the most part, you as a user need not know about other users and their structure in the system, but from time to time, you may see display messages that indicate the system is in use by another user. Do not be concerned, this is normal. Refer to the ACCESSING OTHER PARTITIONS section for additional information. Z

Summary of the content on the page No. 7

System Overview (cont’d) NOTE: Cross Zoning and Swinger Suppression options can help reduce false alarms. Ask your installer if your system is programmed for either of these features. An Abort Window feature exists for all non-fire zones. All non-fire alarm reports are NOT transmitted to the central station if the code + off sequence is entered within the Abort Window time period. Ask your installer if this feature has been programmed. There is also a 5-minute Cancel Window feature in y

Summary of the content on the page No. 8

System Overview (cont’d) Speed Key (Macros) The system can store a string of up to 32 keystrokes, which can be activated anytime by simply pressing the “A, B, C, or D” keys. This feature can be used to make it easy to perform multiple functions at once (such as going to another partition to bypass a zone), or it can be used to simplify an everyday, repeated procedure. Refer to the SPEED KEY section for procedures for using this feature. Using Schedules Your system may have been program

Summary of the content on the page No. 9

System Overview (cont’d) Self-Help Feature Abbreviated user's instructions are built into the system that can be easily viewed on the alpha keypad's message display screen. This feature will prove particularly useful if this manual is not conveniently accessible when you need to perform a system procedure with which you are not familiar. To view the abbreviated instructions: Simply press and hold down the function key of interest until the description starts to appear (about 5 seconds

Summary of the content on the page No. 10

About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a safe location nearby. NOTE: If you have a Touch Screen Keypad connected to your system, refer to the Touch Screen Keypad User Guide for operating instructions. Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Cry

Summary of the content on the page No. 11

Functions of the Keypad LCD DISPLAY SPEAKER ARMED A 1 OFF 2 AWAY 3 STAY LEDS READY MAX TEST BYPASS B 4 5 6 C 7 INSTANT 8 CODE 9 CHIME READY 0 # D FUNCTION KEYS IMPORTANT! When using the keypad to enter codes and commands, sequential key depressions must be made within 3 seconds of one another. If 3 seconds elapses without a key depression, the entry is aborted and must be repeated from its beginning. – 11 – 6160-00-002-V1

Summary of the content on the page No. 12

Functions of the Keypad (cont’d) ALPHA DISPLAY WINDOW: A 2-line, PERIMETER ONLY for a full explanation 32-character Liquid Crystal Display (LCD) of the STAY key. that displays protection point identification 4 MAXIMUM : Arms in manner similar and system status, messages, and user to AWAY mode, but eliminates the entry instructions. delay period, thus providing maximum Disarms the burglary portion of 1 OFF protection. An alarm will occur the system, silences alarms and immediate

Summary of the content on the page No. 13

Functions of the Keypad (cont’d) KEYS 0-9: Used to enter your individual 9 CHIME : Turns on & off the CHIME security access code(s). mode. When on, any entry through a LED READY INDICATOR: (GREEN) Lit protected delay or perimeter zone while the indicates system is ready to be armed, system is disarmed will cause a tone to while unlit indicates system not ready. sound at the Keypad(s). LED ARMED INDICATOR: (RED) Lit ∗∗ READY : When depressed prior to ∗∗ when the system has b

Summary of the content on the page No. 14

Entry/Exit Delays General Information Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. If programmed, a slow beeping will sound throughout the exit delay period. Entry Delay gives you time to disarm the system wh

Summary of the content on the page No. 15

Security Codes and Authority Levels General Information At the time of installation, you were assigned an authority level and a personal four-digit security code, known only to you and yours. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform. As an additional safety feature, other users that do not have a need to know your code can be assigned different security codes, and each user can be given

Summary of the content on the page No. 16

Security Codes and Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing. In summary, there are six authority levels, each having certain system restrictions as shown below. Level 1 Master: Can perform all system functions in assigned partitions, and can add, delete or change Manager and Operator level user

Summary of the content on the page No. 17

Security Codes and Authority Levels (cont’d) General Rules on Authority Levels and Changes • A user may not delete or change the user code of the SAME or HIGHER authority than which he is assigned. • A user may only ADD users to a LOWER authority level. • A user may assign access codes only to those partitions to which the user adding the code has access. (Ex. a user with access to only partition 1 cannot assign codes in partition 2.) • The only way to assign a user's authority level i

Summary of the content on the page No. 18

Security Codes and Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones). CODE 1. Enter Master or Manager code and press the 8 key. 2. Enter the new user's 3-digit User Number (002-250). 3. Enter 4-digit security code for that user. The following prompts will appear. Enter 1 to add a new user code. Entering 0 will ADD NEW USER? change the existing user's co

Summary of the content on the page No. 19

Security Codes and Authority Levels (cont’d) If you as a user have access to other partitions, the MULTI-ACCESS ? keypad will prompt for ability of this new user to 0 = NO , 1 = YES access (GOTO) those partitions. Press 0 (NO) or 1 (YES). If no, the system activates this user code and exits “Add a User” mode. If yes, the keypad prompts for the Global Arm option for this user. Press 1 (YES) if this user will be allowed to try to GLOBAL ARM ? arm more than one partition at the same ti

Summary of the content on the page No. 20

Security Codes and Authority Levels (cont’d) To Change a User's Code CODE 1. Enter Master or Manager code and press the 8 key + user number to be changed. 2. Enter the new code for that user. The system will recognize that the user number is ADD NEW USER? already in use and will prompt whether or not this 0 = NO , 1 = YES is a new user. Enter 0 to change the existing user's code to the code entered in step 3. The system will confirm that the change is allowed USER 002 C


Alternative user manuals
# User manual Category Download
1 Honeywell ADEMCO LYNXR Series User manual Home Security System 47
2 Honeywell ADEMCO LYNXR-EN User manual Home Security System 45
3 Honeywell ADEMCO VISTA VISTA-15PSIA User manual Home Security System 22
4 Honeywell ADEMCO VISTA VISTA-20P User manual Home Security System 533
5 Honeywell ADEMCO VISTA VISTA-15P User manual Home Security System 115
6 Honeywell EQUIPMENT MONITORING SYSTEM W8710A User manual Home Security System 3
7 Honeywell ADEMCO VISTA VISTA-20PSIA User manual Home Security System 14
8 Honeywell EKZ008200B User manual Home Security System 16
9 Honeywell GEH User manual Home Security System 1
10 Honeywell Galaxy 16 User manual Home Security System 30
11 Honeywell Galaxy 16 Plus User manual Home Security System 6
12 Honeywell GALAXY 16103 User manual Home Security System 4
13 Honeywell GES User manual Home Security System 1
14 Honeywell GEC User manual Home Security System 0
15 Honeywell HCD544 User manual Home Security System 1
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9