Honeywell K5305-1V5 user manual

User manual for the device Honeywell K5305-1V5

Device: Honeywell K5305-1V5
Category: Home Security System
Manufacturer: Honeywell
Size: 1 MB
Added : 5/26/2014
Number of pages: 80
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell K5305-1V5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell K5305-1V5.

For your convenience

If looking through the Honeywell K5305-1V5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell K5305-1V5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell K5305-1V5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell K5305-1V5 User manual - Online PDF
Advertisement
« Page 1 of 80 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell K5305-1V5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell K5305-1V5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



ADEMCO VISTA SERIES
VISTA-20P / VISTA-20PSIA
VISTA-15P / VISTA-15PSIA
Security Systems




Installation and Setup Guide



















K5305-1V5 10/04 Rev. A

Summary of the content on the page No. 2

RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early warning fire detection is best achieved by the installation of fire

Summary of the content on the page No. 3

Table Of Contents Features and Installation Highlights............................................................................................................1-1 Capabilities and Functions................................................................................................................................................1-1 Compatible Devices ......................................................................................................................................

Summary of the content on the page No. 4

Table Of Contents (continued) Data Field Programming .................................................................................................................................4-1 About Data Field Programming........................................................................................................................................4-1 ∗ System Setup Fields ( 20 – ∗29) ...........................................................................................................

Summary of the content on the page No. 5

SECT ION 1 Features and Installation Highlights This manual applies to the following Honeywell security systems: ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA-15PCN (collectively referred to as VISTA-15P series) Features and procedures apply to all, except where differences are noted. SIA Installations: The VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls th

Summary of the content on the page No. 6

Installation and Setup Guide Compatible Devices Device VISTA-20P VISTA-15P Notes Addressable Keypads 8 8 6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V Fixed-Word Display Voice Keypad, 6160V Alpha Display Voice Keypad, 6150RF Keypad/Transceiver Touch Screen (AUI) 2 2 Touch Screen (AUI) devices are in addition to the 8 Devices addressable keypads. E.g., Symphony, 6270 4219, 4229 Zone Up to 5 for Up to 2 for Zone numbers are predefined according to the device Expander Modules up to 40 u

Summary of the content on the page No. 7

SECT ION 2 Mounting and Wiring the Control Installing the Control Cabinet and PC Board PUSH Cabinet and Lock 1. Mount the control cabinet to a ON LOCK UNTIL IT CHECK sturdy wall in a clean, dry area, SNAP IS SEATED POSITION TAB SECURELY which is not readily accessible to LOCKED the general public, using fasteners PUSH or anchors (not supplied) with the four cabinet mounting holes. SNAP 2. Remove cabinet door, then remove TAB UNLOCKED the lock knockout from the door. Insert th

Summary of the content on the page No. 8

Installation and Setup Guide CABINET AB CABINET BOARD RECEIVER CIRCUIT BOARD SUPPORTING SLOTS + + CIRCUIT BOARD MOUNTING CLIP CONTROL CIRCUIT BOARD DETAIL A SIDE VIEW MOUNTING OF BOARD - CLIP SUPPORTING SLOTS INSTALLATION WITH RECEIVER CIRCUIT BOARD ANTENNA (2) SCREW (2) GROUNDING LUG (2) WHITE BLACK RED MOUNTING MOUNTING MOUNTING CLIP CLIP CLIP NOTE A COMBINATION OF THESE MOUNTING CLIPS HAS BEEN ANTENNA MOUNT INCLUDED IN YOUR INSTALLATION KIT. (2 PLACES) USE THE APPROPRIATE CLIPS FOR MOUNTING

Summary of the content on the page No. 9

Signal X10 Sync AC AC Output Common Data Mounting and Wiring the Control AC Power, Battery, and Ground Connections 1321 Transformer Connect the 1321 Transformer (1321CN in Wire Run Chart Canada) to terminals 1 and 2 on the Distance from control Wire Size control board. See Wire Run Chart for Up to 50 feet # 20 wire size to use. 50–100 feet # 18 • Use caution when wiring the 100-250 feet # 16 transformer to the control to guard against blowing the transformer fuse 1 2 (the fuse

Summary of the content on the page No. 10

ARMED READY Installation and Setup Guide Sounder (Bell) Connections Basic Connections Make sounder connections to alarm output terminals 3 (+) and 4 (–). • The 12VDC sounder output activates when an alarm occurs. 3 4 • Total current drawn from this output cannot exceed 2 amps (going beyond 2 amps will overload the power supply, or may cause the electronic circuit protecting the sounder output to trip). • You must install a battery, since the battery supplies this current. Supervised

Summary of the content on the page No. 11

BYPASS IN ARMED 1 OFF 2 AWAY 3 STAY READY 4 MAX 5 TEST 6 7 STANT 8 CODE 9 CHIME READY 0 # Mounting and Wiring the Control Keypad Notes Set device addresses. Refer to the instructions included with the devices and set each address according to the Table of Devices Addresses. See Keypad Programming Fields (fields *190-*196) in Section 4. Data Field Programming for details on enabling keypad addresses, assigning keypad partitions and selecting keypad sounding options. IMPORTANT: Each

Summary of the content on the page No. 12

Installation and Setup Guide Hardwire Zones and Zone Expansion Hardwire Zones Normally Open Zones/ N.O. EOLR Zones 1. Connect open circuit devices in parallel across the loop; for EOLR zones, connect the EOLR across the loop wires at the last device. 2. Enable normally open/EOLR zones using Zone Programming mode, “Hardwire Type” prompt. Normally Closed Zones/ N.C. EOLR Zones 1. Connect closed circuit devices in series in the high (+) side of the loop; for EOLR zones, connect the EO

Summary of the content on the page No. 13

  Mounting and Wiring the Control Smoke Detector Notes • • Fire Verification (zone type 16): The control panel will “verify” a fire alarm by • • resetting the smoke detectors after the first alarm trigger, and then waiting 90 seconds for a second alarm trigger. If the smoke detector or thermostat does not trigger again, the control will disregard the first trigger, and no alarm signal will occur. This feature eliminates false alarms due to electrical or physical transients. SIA Inst

Summary of the content on the page No. 14

Installation and Setup Guide RELAY 4229 RELAY CONNECTOR DIP SWITCH 2 FOR SETTING ADDRESS EITHER OR BOTH CAN BE USED AND ZONE "A" RESPONSE TERMINALS ON CONTROL PANEL RELAY 1 TB2 4-PIN CONSOLE PLUG GRN NO C NC DATA OUT (>) 4 (TERM 6) TO CONTROL TAMPER JUMPER POSITION 4229 IN CABINET BLK (–) GROUND 3 (TERM 4) (NOT TAMPER) 4 4229 REMOTE 3 RED 2 (+) 12VDC (TERM 5) (TAMPER PROTECTED) 2 TB1 DATA IN (<) YEL 1 FROM (TERM 7) 1 1 2 3 4 5 6 7 8 9 12 10 11 CONTROL TERMINATE EACH RLY RLY PROGRAMMED ZON

Summary of the content on the page No. 15

Mounting and Wiring the Control Installing a 5800TM • Use this module only if you are using one or more wireless bi-directional keypads or Module keyfobs with a wireless Receiver; 5800TM is not necessary if using a Transceiver (e.g., 5883). • The 5800TM must be set to address 28 (cut red-W1 jumper). • The 5800TM can be used in partition 1 only. • For additional information regarding the 5800TM, refer to the 5800TM’s instructions. 1. Mount the 5800TM next to the RF receiver (betwee

Summary of the content on the page No. 16

Installation and Setup Guide Installing a Keyswitch Keyswitch Connections 1. Connect the 4146 keyswitch's normally open momentary switch to a zone’s (2-8) terminals. Remove the 2000 ohm EOL resistor if connected across the selected zone. 2. Using a standard keypad cable as shown: Connect the yellow and white keyswitch wires to trigger connector pin 3 (+12V). Connect the Red and Green LED wires to the appropriate output 17/output 18 trigger connector pins. 3. Connect a 2000 ohm EOL

Summary of the content on the page No. 17

Mounting and Wiring the Control Connecting Relay Modules, Powerline Carrier Devices and Output Triggers 4204/4229 Relay Modules 1. Mount either remotely or in the control panel. 2. Connect each module to the control’s keypad terminals and set the device addresses as previously described in the Connecting Keypads and Other Addressable Device section. Use the connector harness supplied with the module. Use standard 4-conductor twisted cable for long wiring runs. VISTA-20P: Up to 16 rel

Summary of the content on the page No. 18

Installation and Setup Guide On-Board Triggers Connect field wiring to the desired trigger pin on the 8-pin trigger connector centrally located above the terminal strip. • If using 1361X10 transformer and powerline carrier devices, use the SA4120XM-1 cable (part of 4120TR Trigger Cable). See Wiring the AC Transformer section for transformer connections. • If only using the on-board triggers, you can use a 4-wire cable (N4632-4, supplied with the control) as shown below. 8-PIN

Summary of the content on the page No. 19

{ { Mounting and Wiring the Control Phone Line/Phone Module, and Audio Alarm Verification (AAV) Connections Phone Line Connect incoming phone line and handset wiring to the main terminal block (via an RJ31X jack) as shown in the Summary of Connections diagram at the back of this manual. Wire colors represent the colors of the cable to the RJ31X jack. 4285/4286 Phone Module 1. Make 12V (+) and (–) and data in and data out connections from the phone module to the control, using the

Summary of the content on the page No. 20

Installation and Setup Guide Audio Alarm Verification • Refer to the connection diagrams below. One diagram shows connections when a Connections 4285/4286 Phone Module is used, the other shows connections when the 4285/4286 is not (AAV, “listen-In”) used. • Connections use one of the on-board triggers. • Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80 Menu mode: select zone type 60 and output action 1 (close for 2 seconds) or action 2 (stay


Alternative user manuals
# User manual Category Download
1 Honeywell ADEMCO LYNXR Series User manual Home Security System 47
2 Honeywell ADEMCO LYNXR-EN User manual Home Security System 45
3 Honeywell ADEMCO VISTA VISTA-15PSIA User manual Home Security System 22
4 Honeywell ADEMCO VISTA VISTA-20P User manual Home Security System 533
5 Honeywell ADEMCO VISTA VISTA-15P User manual Home Security System 115
6 Honeywell EQUIPMENT MONITORING SYSTEM W8710A User manual Home Security System 3
7 Honeywell ADEMCO VISTA VISTA-20PSIA User manual Home Security System 14
8 Honeywell EKZ008200B User manual Home Security System 16
9 Honeywell GEH User manual Home Security System 1
10 Honeywell Galaxy 16 User manual Home Security System 30
11 Honeywell Galaxy 16 Plus User manual Home Security System 6
12 Honeywell GALAXY 16103 User manual Home Security System 4
13 Honeywell GES User manual Home Security System 1
14 Honeywell GEC User manual Home Security System 0
15 Honeywell HCD544 User manual Home Security System 1
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9