Honeywell 848 user manual

User manual for the device Honeywell 848

Device: Honeywell 848
Category: Home Security System
Manufacturer: Honeywell
Size: 0.26 MB
Added : 5/26/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell 848. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell 848.

For your convenience

If looking through the Honeywell 848 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell 848 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell 848 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell 848 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell 848 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell 848. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




F FB BII Security II Security Sy System stem
F FB BII Security II Security Sy System stem
® ®
® ®
OMNI 400/OMNI 600
OMNI 400/OMNI 600
® ®
® ®
OMNI 624/OMNI 848
OMNI 624/OMNI 848
User Guide
























N9939V5 4/04 Rev. A

Summary of the content on the page No. 2

Table Of Contents QUICK REFERENCE .................................................................................................................... 3 INTRODUCTION ........................................................................................................................... 6 SYSTEM REFERENCE ................................................................................................................7 ARMING THE SYSTEM......................................................

Summary of the content on the page No. 3

Quick Reference TO ARM THE SYSTEM 1. Check to make sure the system is ready. (The Green READY light is lit.) 2. Enter your 4-digit (or 6-digit) user code. The ARMED/ light will light. 3. Exit through a door designated by your installer as an exit/entry door. NOTE: If you DO NOT EXIT during the exit time and your system installer has programmed your system for Auto-Stay, the system will arm in the Auto-Stay mode. TO DISARM THE SYSTEM 1. Enter through a door designated by you

Summary of the content on the page No. 4

Quick Reference (cont) The following table lists the “Quick Commands” available with this control. Key Description Keypads Comments Quick Arm – if system is ready All keypads Allows you to arm the system without requiring your # 1 user code. User code is always needed to disarm the system. Force Arm – bypasses faulted All keypads Allows you to arm the system even if some zones # 2 zones are faulted. These zones will be automatically bypassed and will be unprotected. BYPASS Quick Byp

Summary of the content on the page No. 5

Quick Reference (Cont’d) The following table provides a summary listing of LED indications when using a LED keypad. SLOW PULSE FAST BLINK SLOW BLINK INDICATOR ON (approx. 600mS ON (approx. 150mS ON (approx. 100mS ON – 600mS OFF) – 150mS OFF) – 900mS OFF) Armed Comm. Fail Alarm – ARM / AC good Syst Batt Trbl – – AC/LB / Ready Program Mode Alarm memory – READY / ✔ 1 Zone Fault Zone Trouble Zone Alarm Zone Bypass 2 Zone Fault Zone Trouble Zone Alarm Zone Bypass 3 Zone Fault Zone T

Summary of the content on the page No. 6

Introduction ® Congratulations on your decision to protect your home or business with the OMNI security system. You have chosen a reliable, state-of-the-art security system that is remarkably easy to operate. Your system has been professionally installed by your local Security Company whose representative can explain the specifics of your system. The keypad is the input and display device for your security system. Your Security Company representative will suggest the model most appropri

Summary of the content on the page No. 7

System Reference ZONE DESCRIPTIONS In the following table, enter a description of the area of protection for each zone. Example: Zone 1 Windows on North side of building. Zone 4 Main entrance to building. Zone Description Zone Description 1 25* 2 26* 3 27* 4 28* 5 29* 6 30* 7 31* 8 32* 9* 33* 10* 34* 11* 35* 12* 36* 13* 37* 14* 38* 15* 39* 16* 40* 17* 41* 18* 42* 19* 43* 20* 44* 21* 45* 22* 46* 23* 47* 24* 48* *

Summary of the content on the page No. 8

System Reference (cont) SEND-HELP ALERT All keypads are equipped with emergency-pair keys. In order to activate the alert, both keys must be pressed at the same time. The type of keypad you have installed dictates which keys you press. Your installer will show you how to activate these emergency keys. The emergency keys used for all keypads are shown below. The following SEND - HELP ALERT is programmed into my system: KEYS DESCRIPTION & # T 7 & 9 & 1 3 NOTE: These

Summary of the content on the page No. 9

System Reference (cont) USER CODE ASSIGNMENTS In the following table, enter the names of the individuals assigned to each user number. User Assigned To… User Assigned To… 1 33* 2 34* 3 35* 4 36* 5 37* 6 38* 7 39* 8 40* 9 41* 10 42* 11 43* 12 44* 13 45* 14 46* 15 47* 16* 48* 17* 49* 18* 50* 19* 51* 20* 52* 21* 53* 22* 54* 23* 55* 24* 56* 25* 57* 26* 58* 27* 59* 28* 60* 29* 61* 30* 62* 31* 63* 32* 64

Summary of the content on the page No. 10

Arming the System IS THE SYSTEM READY? You can arm and disarm the burglar portion of your security system. Before you can arm the system, it must be “ready.” If you have a protected door open, or someone is moving in view of a motion detector, the system will not display the “READY” message. The system is ready if the READY/ light is lit and the display shows: ✔ LCD Keypad: Fixed-Word Keypad: LED Keypad: SYSTEM READY READY/ LED lit READY/ LED lit ✔ ✔ NOTE: If programmed by your i

Summary of the content on the page No. 11

Arming the System (cont) WHEN THE SYSTEM IS NOT READY If the system is not ready to be armed, the READY/ light will be off and the ✔ display will show which zone or zones are not ready. The following conditions will be indicated by the zone lights (LED keypad) or described on the display: Fast Blink ...............................Alarm or tamper condition Slow Blink/Low Intensity ...Bypass Slow Pulse ..............................Trouble, problem with RF receiver, or low battery Solid O

Summary of the content on the page No. 12

Arming the System (cont) TO ARM THE SYSTEM IN INSTANT MODE In INSTANT mode, all alarm sensors, including doors that normally have a delay to allow you to disarm the system, will report an alarm immediately if activated. Check to make sure the system is READY/ . When it is ready, press: ✔ INSTANT / followed by your user code. When the system has been armed successfully, the ARM/ light and the INSTANT/ light are lit, and the following is displayed: LCD Keypad: Fixed-Word Keypad: LED

Summary of the content on the page No. 13

Arming the System (cont) TO BYPASS A ZONE The Bypass function excludes a zone of protection from the security system until it is unbypassed (either by using the unbypass procedure or when you disarm the system). Bypassing can only be done while the system is disarmed. NOTE: 24-hour zones may be bypassed, but can only be unbypassed if the zone is not faulted (condition has been cleared). button. Then enter your user code and the zone number Press the BYPASS/ to be bypassed, as follows:

Summary of the content on the page No. 14

Disarming the System When you disarm the system, you disarm only the burglar portion of your system; any smoke or heat detectors and panic keys will remain armed. You must enter through a designated entry door and disarm the system within the time allowed. You can have different amounts of time for different entry points. See your system reference sheet (page 7) for the times established for your system. To disarm your system: Enter your user code. If no alarms have taken plac

Summary of the content on the page No. 15

User Codes TO ADD OR CHANGE A USER CODE Users can be added or changed directly at the keypad. Your system can have up to 15 (OMNI400 and OMNI600), 32 (OMNI624), or 64 (OMNI848) different user codes, with each assigned to one of four authority levels and to a primary partition (OMNI624 and OMNI848 only). The authority level determines the functions that user can perform. In addition, your system can be set up for 4-digit or 6-digit user codes. Ask your installer which type of user code

Summary of the content on the page No. 16

Miscellaneous Commands TO DELETE A USER CODE To delete a user, press the CODE/ button followed by the 4-digit (or 6-digit) master user code. Enter the user number, then press [#] to delete. For example, to delete user 3, do the following: Master User Code User ID # to delete CODE / 03 [#] NOTE: User no. 1, the master user, cannot be deleted but it can be changed using the ADD OR CHANGE A USER CODE procedure. DURESS Your system can be programmed to send an emergency signal to th

Summary of the content on the page No. 17

Miscellaneous Commands (cont) QUICK BYPASS If you have Quick Bypass programmed for your system, you can bypass zones without entering your user code. The Quick Bypass procedure is: BYPASS / 2-digit Zone No. (e.g., 01 for zone 1) NOTE: Bypassed zones are not protected when the system is armed. After the bypass command has been accepted, the keypad sounds one long beep. The zone light of the bypassed zone(s) slowly blinks, or the display shows: LCD Keypad: Fixed-Word Keypad: LED Keyp

Summary of the content on the page No. 18

Miscellaneous Commands (cont) CHANGE PARTITION (OMNI624 and OMNI848 ONLY) To arm or disarm other partitions from your keypad, enter the following: [1-3, 0, 9] # 0 where: 1-3* = the desired partition you wish to change to When you enter a partition number (1-3*), the system displays the current armed state for that partition. You can then arm or disarm the partition by entering the arming/disarming command. 0 = arms all partitions 9 = disarms all partitions * Partition 3 is avai

Summary of the content on the page No. 19

Miscellaneous Commands (cont) VIEW QUICK COMMAND LIST (LCD Keypads on OMNI624 and OMNI848 ONLY) To view a display of available quick commands, press: + + . # 5 0 To step through the available quick commands, press . # To exit the quick command list, press . T VIEW TIME (LCD KEYPADS ONLY) To view the system time, press: + + . A typical display is # 5 1 as follows: Jan 27, 2001 08:15A SET TIME To set the time, press: + + user code (not required if so # 3 programmed by in

Summary of the content on the page No. 20

Miscellaneous Commands (cont) DISPLAY ZONE DIRECTORY (LCD KEYPADS ONLY) To view a list of the zones in the current partition, press + . The # 4 zones will automatically scroll. USER LOG VIEW (LCD KEYPADS ONLY) To view the system log, press: + , + + user code.* # 5 3 (*The user code is not required if so programmed by installer.) When the command is accepted, the display will show the most recent event. STAY Pressing either / or exits this mode. T Pressing any other key advances


Alternative user manuals
# User manual Category Download
1 Honeywell ADEMCO LYNXR Series User manual Home Security System 47
2 Honeywell ADEMCO LYNXR-EN User manual Home Security System 45
3 Honeywell ADEMCO VISTA VISTA-15PSIA User manual Home Security System 22
4 Honeywell ADEMCO VISTA VISTA-20P User manual Home Security System 533
5 Honeywell ADEMCO VISTA VISTA-15P User manual Home Security System 115
6 Honeywell EQUIPMENT MONITORING SYSTEM W8710A User manual Home Security System 3
7 Honeywell ADEMCO VISTA VISTA-20PSIA User manual Home Security System 14
8 Honeywell EKZ008200B User manual Home Security System 16
9 Honeywell GEH User manual Home Security System 1
10 Honeywell Galaxy 16 User manual Home Security System 30
11 Honeywell Galaxy 16 Plus User manual Home Security System 6
12 Honeywell GALAXY 16103 User manual Home Security System 4
13 Honeywell GES User manual Home Security System 1
14 Honeywell GEC User manual Home Security System 0
15 Honeywell HCD544 User manual Home Security System 1
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9