Honeywell 3.5 user manual

User manual for the device Honeywell 3.5

Device: Honeywell 3.5
Category: Home Security System
Manufacturer: Honeywell
Size: 0.71 MB
Added : 6/7/2014
Number of pages: 96
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell 3.5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell 3.5.

For your convenience

If looking through the Honeywell 3.5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell 3.5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell 3.5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell 3.5 User manual - Online PDF
Advertisement
« Page 1 of 96 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell 3.5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell 3.5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




 

 


 



 
   






























N7001V5 5/04 Rev A

Summary of the content on the page No. 2

ii

Summary of the content on the page No. 3

. Table of Contents •••••••••••••••••••••••••••••••••••••••••••••••••• List of Figures...................................................................................................................................... v Conventions Used in This Manual..................................................................................................... vi SECTION 1: General Description.....................................................................................................

Summary of the content on the page No. 4

Table of Contents SECTION 7: Setting the Real-Time Clock........................................................................................ 7-1 General Information ...........................................................................................................................................................7-1 Setting the Time and Date ...............................................................................................................................................

Summary of the content on the page No. 5

List of Figures •••••••••••••••••••••••••••••••••••••••••••••••••• Figure 3-1: Installing the Lock...............................................................................................................................................3-1 Figure 3-2: Cabinet Attack Resistance Considerations.........................................................................................................3-2 Figure 3-3: Mounting the PC Board..................................................

Summary of the content on the page No. 6

Conventions Used in This Manual •••••••••••••••••••••••••••••••••••••••••••••••••• Before you begin using this manual, it is important that you understand the meaning of the following symbols (icons). These notes include specific information that must be followed if you are installing this system for U L a UL Listed application. These notes include information that you should be aware of before continuing with the installation, and that, if not observed, could result in ope

Summary of the content on the page No. 7

SECT ION 1 General Description •••••••••••••••••••••••••••••••••••••••••••••••••• About the VISTA-40 The VISTA-40 is a 2-partition, UL Listed control panel with the following features: • Provides 64 zones using hardwired, polling loop and wireless. • Provides 70 user access codes Features Hardwire and Optional Expansion Zones • Provides 9 hardwire zones. • Supports up to 16 2-wire smoke detectors on zone 1. • Supports up to 50 2-wire latching glassbreak detectors on zone 8. • Supp

Summary of the content on the page No. 8

VISTA-40 Installation and Setup Guide Event Log • Provides an event log (history log) that can store up to 100 events. • Can print the event log on a serial printer using a 4100SM. • Can view the event log on an alpha keypad. Additional Features • Provides up to 20 installer-defined, custom words that can be used for zone descriptors. • Contains a built-in User’s Manual, which provides the end user with a brief explanation of the function of a key when the user presses any of the functio

Summary of the content on the page No. 9

SECT ION 2 Partitioning •••••••••••••••••••••••••••••••••••••••••••••••••• Theory of Partitioning This system provides the ability to arm and disarm up to 2 different areas, as if each had its own control. These areas are called partitions. A Partitioned system allows the user to disarm certain areas while leaving other areas armed, or to limit access to certain areas to specific individuals. Each system user can be assigned to operate any or all partitions, and can be given a diffe

Summary of the content on the page No. 10

VISTA-40 Installation and Setup Guide 2-2

Summary of the content on the page No. 11

SECT ION 3 Installing the Control ••••••••••••••••••••••••••••••••••••••••••••••••• This section describes the procedures for mounting and wiring the control panel and all the peripheral devices. Mounting the Control Cabinet To mount the control cabinet, perform the following steps: Step Action 1 Before mounting the circuit board, remove the metal knockouts for the wiring entry that you will be using. DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS AFTER THE CIRCUIT BOARD HAS BEEN INSTALLED

Summary of the content on the page No. 12

+ + + VISTA-40 Installation and Setup Guide (Shows typical local Grade A listing installation) RUN BELL WIRES IN CONDUIT PLUG THIS KNOCKOUT TO PLUG AN UNUSED KNOCKOUT OPENING, REMOVE KNOCKOUT AND INSTALL A PAIR OF CLIP-ON DOOR DISC PLUGS AND A CARRIAGE BOLT AS SHOWN. TAMPER SWITCH DISC PLUGS (DIMPLES IN DISC CABINET PC PLUG SHOULD REGISTER INSIDE MOUNTING KNOCKOUT BOARD KNOCKOUT OPENING) HOLE OPENING PLUG THIS (4 PLACES) CARRIAGE BOLT KNOCKOUT PLUG THIS HEX NUT AND KNOCKOUT WASHER CABINET SIDE

Summary of the content on the page No. 13

Section 3 - Installing the Control Installing the Keypads • Up to 31 addressable keypads (addresses 00-30) Addressing the Keypads may be used (you may need to use an auxiliary The keypads will not operate until they are power supply if the 750mA aux. output is physically addressed and enabled in the exceeded). The following keypads may be used: system’s Device Programming in the #93 Menu • 2-line alpha display, 6139/6160 Mode. Set each keypad for an individual address (00-15)

Summary of the content on the page No. 14

VISTA-40 Installation and Setup Guide Installing External Sounders The VISTA-40 provides a bell circuit output for Alarm Output Supervision operating fire and burglary alarm notification When supervision is enabled, the VISTA-40 monitors appliances. The alarm output is rated as follows: the alarm output wiring for open and short circuit 10VDC – 14VDC, 1.7A max., power-limited. faults while the output is inactive. The system provides The output has the following options: a trouble

Summary of the content on the page No. 15

Section 3 - Installing the Control POLARIZING DIODES (MUST MOUNT AT INDICATING DEVICE) PANEL BELL TO HORN OTHER BELL BELL DEVICES PANEL BELL NONPOLARIZED BURGLARY POLARIZED FIRE INDICATING DEVICES INDICATING DEVICE non_polar_devices Figure 3-7: Wiring Nonpolarized Burglary Devices Supervising the Alarm Output Using a Siren Driver To wire the alarm output using the supervision feature, To install a siren driver, perform the following steps: perform the following steps: Step Action Step A

Summary of the content on the page No. 16

{ { VISTA-40 Installation and Setup Guide Incoming Handset Telco Line 26 27 28 29 30 TERMINALS EARTH GROUND ON CONTROL INCOMING TELCO LINE DIRECT CONNECT TIP CORD RJ31X PREMISES RING JACK PHONES PLUG Figure 3-8: Telephone Line Connections Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9 The maximum zone resistance is 100 ohms for • Connect N.C. devices in series with the high (+) zones 1 and 8, and 300 ohms for all other side of the loop. The 2K EOL resistor must be z

Summary of the content on the page No. 17

ZONE 1 SMOKE 2k EOLR Section 3 - Installing the Control Using 2-Wire Smoke Detectors on Zone 1 Zone 1 can support up to 16 2-wire smoke detectors. (+) (+) 10 The alarm current on zone 1 supports only one 2-WIRE SMOKE smoke detector in the alarmed state. DETECTOR 11 (-) (-) Compatible 2-Wire Smoke Detectors DETECTOR TYPE DEVICE MODEL # Photoelectric, direct-wire System Sensor 2400 Figure 3-10: 2-Wire Smoke Detector on Zone 1 Photoelectric w/heat sensor, direct-wire System Se

Summary of the content on the page No. 18

VISTA-40 Installation and Setup Guide _ TO AUXILIARY _ POWER + TERMINALS + 4-WIRE EOL POWER SMOKE SUPERVISION DETECTORS RELAY MODULE + + A77-716B _ _ NOTES: NO CONNECTION · PROGRAM THE RELAY TO SHOWN POWERED. TRANSFER ON FIRE ZONE RELAY OPENS WHEN POWER IS LOST. RESET (ACTIVATION CODE 54). SEE 4204 RELAY MODULE C NC NO SECTION FOR DETAILS. RESET 2k HEAT · SECOND CODE AND OFF EOLR RELAY 1, 2, 3, OR 4 DETECTOR ENTERED AT CONSOLE MOMENTARILY INTERRUPTS 4204 RELAY MODULE DETECTOR POWE

Summary of the content on the page No. 19

Section 3 - Installing the Control CONTROL PANEL 6 7 4 8 7 6 5 + – 4-WIRE SMOKE EOL POWER DETECTORS SUPERVISION 4 RELAY MODULE + + A77-761B 3 - - SHOWN POWERED. RELAY OPENS WHEN -2 P1 POWER IS LOST +1 2000 JUMPER OHM EOLR HEAT DETECTOR JUMPER P1 ON 333 MODULE MUST BE IN + - "B" POSITION FOUR-WIRE DETECTOR CIRCUIT TO FIRE ZONE TERMINALS 1 2 3 4 12 NO NC C 4204 Figure 3-13: Wiring a 333PRM using a 4204 CONTROL PANEL 6 7 4 8 7 6 5 + – 4-WIRE SMOKE EOL POWER DETECTORS SUPERVISION 4 RELAY MO

Summary of the content on the page No. 20

VISTA-40 Installation and Setup Guide Using 2-Wire Latching Glassbreaks on Zone 8 GLASSBREAK DETECTOR Zone 8 can support 2-wire glassbreak detectors. The ZONE 8 2000 (+) zone provides enough standby current to power up to 50 21 OHMS 2-wire glassbreak detectors meeting the requirements EOLR LATCHING TYPE GLASS listed below. BREAK DETECTOR LOOP (-) 22 Compatible Glassbreak Detectors Use detectors that meet the following ratings: Standby 5VDC–13.8VDC Figure 3-15: Wiring Latching Glassbr


Alternative user manuals
# User manual Category Download
1 Honeywell ADEMCO LYNXR Series User manual Home Security System 47
2 Honeywell ADEMCO LYNXR-EN User manual Home Security System 45
3 Honeywell ADEMCO VISTA VISTA-15PSIA User manual Home Security System 22
4 Honeywell ADEMCO VISTA VISTA-20P User manual Home Security System 533
5 Honeywell ADEMCO VISTA VISTA-15P User manual Home Security System 115
6 Honeywell EQUIPMENT MONITORING SYSTEM W8710A User manual Home Security System 3
7 Honeywell ADEMCO VISTA VISTA-20PSIA User manual Home Security System 14
8 Honeywell EKZ008200B User manual Home Security System 16
9 Honeywell GEH User manual Home Security System 1
10 Honeywell Galaxy 16 User manual Home Security System 30
11 Honeywell Galaxy 16 Plus User manual Home Security System 6
12 Honeywell GALAXY 16103 User manual Home Security System 4
13 Honeywell GES User manual Home Security System 1
14 Honeywell GEC User manual Home Security System 0
15 Honeywell HCD544 User manual Home Security System 1
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9