Emerson 400508-02 user manual

User manual for the device Emerson 400508-02

Device: Emerson 400508-02
Category: Home Security System
Manufacturer: Emerson
Size: 1.24 MB
Added : 8/16/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 400508-02. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 400508-02.

For your convenience

If looking through the Emerson 400508-02 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 400508-02 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 400508-02 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 400508-02 User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 400508-02 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 400508-02. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

P/N 400508-02
Revision: A2
Date: August 23, 2000
© EMERSON Motion Control, Inc. 2000
FM-3 Programming Module
Installation Manual

Summary of the content on the page No. 2

Summary of the content on the page No. 3

FM-3 Programming Module Installation Manual Information furnished by EMERSON Motion Control is believed to be accurate and reliable. However, no responsibility is assumed by EMERSON Motion Control for its use. EMERSON Motion Control reserves the right to change the design or operation of the equipment described herein and any associated motion products without notice. EMERSON Motion Control also assumes no responsibility for any errors that may appear in this document. Information in this do

Summary of the content on the page No. 4

© EMERSON Motion Control, Inc. 2000 Part Number: 400508-02 Revision: A2 Date: August 2000 Printed in United States of America Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of EMERSON Motion Control. The following are t

Summary of the content on the page No. 5

Customer Service It is EMERSON Motion Control’s goal to ensure your greatest possible satisfaction with the operation of our products. We are dedicated to providing fast, friendly, and accurate assistance. That is why we offer you so many ways to get the support you need. Whether by phone, fax or modem, you can access EMERSON Motion Control support information 24 hours a day, seven days a week. EMERSON Motion Control 12005 Technology Drive Eden Prairie, Minnesota 55344 U.S.A. FAX (952)995-8

Summary of the content on the page No. 6

Need on-site help? EMERSON Motion Control provides service, in most cases, the next day. Just call EMERSON’s customer service center when on-site service or maintenance is required. Training Services (800)397-3786 or Fax (952)995-8011 EMERSON Motion Control maintains a highly trained staff of instructors to familiarize customers with EMERSON Motion Control’s products and their applications. A number of courses are offered, many of which can be taught in your plant upon request. Application E

Summary of the content on the page No. 7

Document Conventions Manual conventions have been established to help you learn to use this manual quickly and easily. As much as possible, these conventions correspond to those found in other Microsoft® 1 Windows® documentation. Menu names and options are printed in bold type: the File menu. Dialog box names begin with uppercase letters: the Axis Limits dialog box. Dialog box field names are in quotes: “Field Name”. Button names are in italic: OK button. Source code is printed in Courier font

Summary of the content on the page No. 8

Safety Instructions General Warning Failure to follow safe installation guidelines can cause death or serious injury. The voltages used in the product can cause severe electric shock and/or burns, and could be lethal. Extreme care is necessary at all times when working with or adjacent to it. The installation must comply with all relevant safety legislation in the country of use. Qualified Person For the purpose of this manual and product, a “qualified person” is one who is familiar with the

Summary of the content on the page No. 9

Safety Considerations Safety Precautions This product is intended for professional integration into a complete system. If you install the product incorrectly, it may present a safety hazard. The product and system may use high voltages and currents, carry a high level of stored electrical energy, or control mechanical equipment that can cause injury. You should give close attention to the electrical installation and system design to avoid hazards either in normal operation or in the event o

Summary of the content on the page No. 10

relevant safety legislation in the country of use. AC supply isolation device The AC supply must be removed from the drive using an approved isolation device or disconnect before any servicing work is performed, other than adjustments to the settings or parameters specified in the manual. The drive contains capacitors which remain charged to a potentially lethal voltage after the supply has been removed. Allow at least 3 minutes for Epsilon and 30 seconds for E Series drives after removing t

Summary of the content on the page No. 11

Table of Contents Customer Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Reference Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Introduction 1 Installation 3 Basic Installation Notes . .

Summary of the content on the page No. 12

x

Summary of the content on the page No. 13

FM-3 Programming Module Installation Manual Introduction FM-3 is a compact and rugged function module that attaches to the front of the E Series drive. It provides eight digital input lines and four digital output lines, in addition to the four input and three output lines available on the E Series EN drive. Unlike other function modules, the FM-3 offers complex motion profiling. A complex motion profile consists of two or more indexes that are executed in sequence such that the final veloc

Summary of the content on the page No. 14

Inputs Outputs 10-30 VDC Sync. Sync. Output Exp. I/O Input FM-3 Programming Module Installation Manual The FM-3 stores E Series drive setup parameters within the module itself. This allows you to transfer the FM-3 to another E Series drive without losing setup parameters. Fastening Latch 3 Row by 12 Character Display Soft Keys Direction Arrow Keys Programming Module 100-Pin Connector 1 2 3 4 5 Inputs 6 485 + 7 485 - 8 Expanded I/O SHLD 1 2 Sync. Intput 3 Outputs MODEL FM-3 4 PART 960499-01 + RE

Summary of the content on the page No. 15

FM-3 Programming Module Installation Manual Installation Basic Installation Notes You are required to follow all safety precautions during start-up such as providing proper equipment grounding, correctly fused power and an effective Emergency Stop circuit which can immediately remove power in the case of a malfunction. See the “Safety Considerations” section for more information. Mechanical Installation The FM-3 detects and verifies the drive serial number when its attached to an E Series dri

Summary of the content on the page No. 16

FM-3 Programming Module Installation Manual Gently pull the FM away from Press down on the the drive. A slight rocking latch located on motion may be used to loosen the top of the FM. the FM's connector. 2 3 Grip the FM 1 on each side of the LCD. 4 Continue pulling the top of the FM away from the drive until the connector clears the drive. Lift the FM out of the aligning tab slot and away from the drive. Figure 4: Detaching the FM-3 from the Drive Connections Caution Do not attach or detach the

Summary of the content on the page No. 17

Installation Software Installation Emerson Motion Control PowerTools® FM-3 software was designed for users who need access to all setup options and diagnostic information for the drive. The software provides access to all commonly used drive parameters. PC System Configuration Required: • Microsoft® Windows® 95/98 or Microsoft Windows NT® 4.0 (service pack 3) • Serial port • Mouse • 3.5" floppy drive for installation Recommended: • 16 MB or more RAM for Windows 95/98, and 32 MB or more for Win

Summary of the content on the page No. 18

FM-3 Programming Module Installation Manual 3. In the Run dialog box, type a:/setup, where a is the letter assigned to your 3.5" floppy drive. 4. Click the OK button, then follow the instructions on your screen. Installation will take about five minutes. The install program automatically: • Creates the directory on your hard drive named: C:\EMERSON\PT-FM3 • Creates a new Windows group called "EMERSON Motion Control-FM3". • Loads the required DLL’s into your Windows system directory. • Loads

Summary of the content on the page No. 19

Installation Exiting the Software Choose File from the menubar, then click Exit. If you are using the keyboard, press the shortcut key combination Alt+F, X. If you made changes, PowerTools displays an Alert dialog box asking whether you want to save your current work. Click the Yes button or press Enter to save your work, or click the No button to quit without saving. Accessing Help All PowerTools tabs and dialog boxes provide a Help button. This retrieves help for that particular subject an

Summary of the content on the page No. 20

FM-3 Programming Module Installation Manual 8


Alternative user manuals
# User manual Category Download
1 Emerson 460 User manual Home Security System 2
2 Emerson Liqui-tect MC68HC16Z1 User manual Home Security System 1
3 Emerson MICRO MOTION F-SERIES SENSOR User manual Home Security System 43
4 Emerson AV101 User manual Home Security System 26
5 Emerson AC4 User manual Home Security System 8
6 3Com 1000BASE-T-GBIC User manual Home Security System 0
7 Sony BRCSDP12 User manual Home Security System 3
8 3Com TECHD-0000000122 User manual Home Security System 1
9 Sony SSC-M354 User manual Home Security System 3
10 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
11 Sony SNC-RX SNC-CS50 User manual Home Security System 4
12 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
13 Sony CD-7226 User manual Home Security System 1
14 Sony Ssc-M383 User manual Home Security System 6
15 Sony Snc Df50n User manual Home Security System 1