Bosch Appliances D7212GV4 user manual

User manual for the device Bosch Appliances D7212GV4

Device: Bosch Appliances D7212GV4
Category: Home Security System
Manufacturer: Bosch Appliances
Size: 0.5 MB
Added : 11/16/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bosch Appliances D7212GV4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bosch Appliances D7212GV4.

For your convenience

If looking through the Bosch Appliances D7212GV4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bosch Appliances D7212GV4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bosch Appliances D7212GV4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bosch Appliances D7212GV4 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bosch Appliances D7212GV4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bosch Appliances D7212GV4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1








Control Panels
D9412GV4/D7412GV4/D7212GV4

en Owner's Manual Supplement



Summary of the content on the page No. 2

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement System Requirements Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2007: • UL Listed and Classified control unit Model D9412GV4, D7412GV4, or D7212GV4 • UL Listed and Classified keypad Model D1256, D1257, D1260, D1255, D1255R, or D1255 RW • UL Listed Local Bell The minimum firmware requirements for SIA CP-01 compliance are: Control Panel Firmware Version D9412GV4 1.00 or later D7412G

Summary of the content on the page No. 3

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 1.0 Introduction 4 2.0 General Commands 4 2.1 Two-Man Rule 4 2.2 Early Ambush 5 2.3 Easy Exit Control 5 2.4 Passcode Follows Scope 6 2.5 Passcode Controlled Menu 7 2.6 Walk Tests 8 2.7 Door Activated Custom Function 11 2.8 Passcode Functions 11 2.9 Access Level Control 13 2.10 Door Control 14 2.11 Delete User [COMMAND 53] 18 2.12 Add/Change User - [COMMAND 56] 19 3.0 SIA CP-01 Compliance Information 27 3.1 System Require

Summary of the content on the page No. 4

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 1.0 Introduction This document supplements the Security System Owner’s Manual (P/N: 71-06633-000) with the features for the GV4 Series. The instructions for the commands listed in this document replace those commands in the Security System Owner’s Manual. Refer to the Owner’s Manual for the operation of your new security system and its other basic features. Place this supplement inside the Security System Owner’s Manual. 2

Summary of the content on the page No. 5

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 2.2 Early Ambush 2.2.1 Description Early Ambush adds an extra step to the disarming process by requiring the entry of an additional passcode to confirm that the area is secure. The second passcode can be same as the first or different, depending upon the configuration. The first entry disarms the area and the second entry stops an automatic timer from sending a duress event. I have this feature. I do not have this feature.

Summary of the content on the page No. 6

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 2.3.2 Using Easy Exit Control Switching armed states from Master to Perimeter: 1. Ensure that the keypad shows idle master armed text. 2. Press the [COMMAND] key. The keypad shows SYSTEM COMMAND. 3. Press [3] to Perimeter Arm. 4. The keypad display shows the Exit Delay countdown. 5. Enter or exit from the premises. Switching armed states from Perimeter to Master: 1. Ensure that the keypad shows idle perimeter armed text. 2. Pr

Summary of the content on the page No. 7

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 2.4.2 Using Passcode Follows Scope Arming from a keypad with Panel Wide scope and Passcode Follows Scope enabled: 1. Ensure that the keypad shows idle disarmed text. 2. Ensure that you have a valid passcode with the authority to Passcode Arm in all areas. 3. Enter your passcode by pressing the passcode digits followed by the [ENTER] or [ENT] key. 4. The keypad shows ARMING: 12345678 to indicate which areas are ready to enter, ex

Summary of the content on the page No. 8

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 2.5.2 Using Passcode Controlled Menus On a D1255 Keypad 1. Press the [ESC] key. The keypad shows ENTER PASSCODE. 2. Enter your passcode by pressing the passcode digits followed by the [ENT] key. The first menu item for which you have authority appears. On a D1260 Keypad: 1. Press the Menu softkey in the lower right corner. The keypad shows ENTER PASSCODE then press [ENTER]. 2. Enter your passcode by pressing the passcode digits f

Summary of the content on the page No. 9

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Table 1: Walk Test Menu Access Test Type Command Menu Function Name Point Types Sequence Tested WALK TEST ? Walk [COMMAND][4][4] Visible Perimeter and Interior Fire [COMMAND][5][8] FIRE TEST ? Fire and 24- hour INVISIBLE TEST ? Invisible Not applicable Invisible Perimeter and Interior I have this feature. I do not have this feature. 2.6.2 Using Walk Test On a D1255 Keypad 1. If you use the command sequence, pre

Summary of the content on the page No. 10

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Table 2: Hardware States of Points Display Text Hardware State 1PT### NORMAL HW Normal 1PT### OPEN HW Opened 1PT### SHORT HW Shorted 1PT### MISSNG HW Missing 9. Activate the point’s sensor and observe the appropriate state change. 10. Press the [NEXT] key to advance to the next untested point within the scope of the keypad. 11. Repeat Steps 8 through 10 until all points are tested. On a D1260 Keypad 1. If you use t

Summary of the content on the page No. 11

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement The point state can be NORMAL, OPEN, SHORT, or MISSING. 7. Activate the point’s sensor and observe the state change. 8. Repeat Steps 5 through 7 until all points are tested. 2.7 Door Activated Custom Function 2.7.1 Description The D9412GV4 and D7412GV4 allow a custom function to be activated when user credentials are presented to a D9210C Door Controller Reader. The custom function executes as if the user performed a funct

Summary of the content on the page No. 12

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement I have One of the following Passcode Functions configured: Arm / Disarm (default) - All areas within the scope of the user and keypad have their arm state changed. If the current area is armed, it will disarm. If the current area is disarmed, it will arm. Cycle Door / Grant Access - The door associated with the keypad will momentarily unlock. If enabled, the current area will disarm or switch to perimeter armed, then (if enabl

Summary of the content on the page No. 13

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement The Dual Authentication process is also valid if the access credential is presented first. Access credentials are usually a token or a card and are provided by your dealer. The control panel requires the passcode and the credential of the same user to be presented within a configurable amount of time. The allowed duration of time can be between 10 to 45 seconds. Consult your dealer if the travel time between the keypad and the D

Summary of the content on the page No. 14

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement On a D1260 Keypad 1. Activate the door’s custom functions. Refer to Section 2.7.2 Using Door Activated Custom Functions. 2. Ensure that the display shows idle disarmed text. 3. Press the Menu softkey to enter the function list. Then press the Next softkey repeatedly until you reach the Change Level? prompt. 4. Press the Change Level ? softkey. Access Control Level appears, indicating that you are affecting the authority levels o

Summary of the content on the page No. 15

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement You can use the function list in place of steps 2 and 3 to start this function. 1. Press the [MENU] key to enter the function list. 2. Press [NEXT] repeatedly until you reach the DOOR CTRL? prompt. 3. Press [ENT]. 4. The first sub-function that appears is CYCLE DOOR?. You can cycle through the three sub-functions by pressing [PREV] and [NEXT]. On a D1260 Keypad 1. Ensure that the display shows idle disarmed text. 2. P

Summary of the content on the page No. 16

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Table 3: Key to Symbols Symbol Description --- Door is not active, not in scope, or user does not have access level authority C Door is timed door sequence U Strike and shunt are latched active (held open) X Strike and shunt are deactivated (secured) P There is a problem with the door; call your security company 2. Enter the number of the door to cycle then press [ENT]. This door cycles and the display changes to reflect th

Summary of the content on the page No. 17

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement The display shows UNLOCK DOOR 1 2 3 U 5 6 7 8 This indicates that all doors are in a normal state, except for Door 4, which is unlocked. 4. Press [ESC] to leave this sub-function, or enter another door number to unlock. 2.10.5 Secure Door? Depending on your keypad, the operations in this section are the same, but the keypad display and keys are slightly different. 1. To secure a door to prohibit access to users regardless of

Summary of the content on the page No. 18

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement Each of these sub-functions acts as a toggle switch. To return a door to its normal state, follow the same procedure used to change its state. For example, if Door 3 is secured, to return it to its normal state, at the SECURE DOOR? prompt, enter [3] and press [ENT]. The door is no longer secured and the X is replaced with the number 3. 2.11 Delete User [COMMAND 53] 2.11.1 Description Use this function to delete a personal pas

Summary of the content on the page No. 19

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 6. The display shows DELETE USER ##?. Press [ENT] to delete user, and USER DELETED appears. If the user number is not in the system, NOT IN USE appears. If you made an error and do not wish to delete this user, press [ESC]. 2.12 Add/Change User - [COMMAND 56] 2.12.1 Description Use this function to add or change a passcode or card without assistance from your security company. Before adding or changing a passcode or card, you mus

Summary of the content on the page No. 20

D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement 7. ENTER NEW CODE appears. Enter the new passcode followed by [ENT]. ENTER AGAIN appears. 8. Enter the new passcode a second time for confirmation. Press [ENT]. The display shows PASSCODE ADDED (or PASSCODE CHANGED if the user number was already in the system). For systems with access control, the following prompts are available: ADD CARD? and CHANGE CARD?. Refer to Systems With Access Control on page 22 for details. The s


Alternative user manuals
# User manual Category Download
1 Bosch Appliances 800 User manual Home Security System 2
2 Bosch Appliances 3.21.0002 User manual Home Security System 3
3 Bosch Appliances 500 User manual Home Security System 1
4 Bosch Appliances 00P User manual Home Security System 1
5 Bosch Appliances 100 User manual Home Security System 2
6 Bosch Appliances 8-Dec User manual Home Security System 21
7 Bosch Appliances 2601 User manual Home Security System 0
8 Bosch Appliances 4000 User manual Home Security System 0
9 Bosch Appliances 600 User manual Home Security System 0
10 Bosch Appliances 800 User manual Home Security System 0
11 Bosch Appliances APC-AEC21-UPS1Z User manual Home Security System 2
12 Bosch Appliances 8500 User manual Home Security System 2
13 Bosch Appliances AEC-AEC21-EXT1 User manual Home Security System 5
14 Bosch Appliances 7000 User manual Home Security System 0
15 Bosch Appliances 8008 User manual Home Security System 2
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9