Bosch Power Tools 2000 user manual

User manual for the device Bosch Power Tools 2000

Device: Bosch Power Tools 2000
Category: Home Security System
Manufacturer: Bosch Power Tools
Size: 1.27 MB
Added : 11/16/2013
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bosch Power Tools 2000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bosch Power Tools 2000.

For your convenience

If looking through the Bosch Power Tools 2000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bosch Power Tools 2000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bosch Power Tools 2000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bosch Power Tools 2000 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bosch Power Tools 2000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bosch Power Tools 2000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




2000 Series














Program Entry Guide
EN Control Panels

Summary of the content on the page No. 2

2000 Series | Program Entry Guide | About This Manual EN | 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control Panels (except D2012/D2012U). This guide follows the organization of the D2212 Product Handler in the D5200 Programmer. The table of contents lists each programming section, program item, and its page number. Throughout this manual, programming prompts are shown in bold italic letters (such as Phone 1). Use the Program

Summary of the content on the page No. 3

2000 Series | Program Entry Guide | Contents EN | 3 Contents 1.0 System Configuration......................................5 2.0 Phone ..................................................................7 2.1 Phone Routing Set to No...................................7 2.2 Phone Routing Set to Yes..................................7 3.0 Reports..............................................................11 4.0 Receiver............................................................15 4.1 Mode

Summary of the content on the page No. 4

2000 Series | Program Entry Guide | Contents EN | 4 Figures Figure 1: Pulse Report Groups......................................18 Figure 2: View Mode......................................................65 Figure 3: Modify Mode ..................................................66 Tables Table 1: Phone Routing Set to No..................................7 Table 2: Modem II Reports Chart................................15 Table 3: Pulse Format.............................................

Summary of the content on the page No. 5

2000 Series | Program Entry Guide | 1.0 System Configuration EN | 5 3 Keyswitch 1.0 System Configuration Default: Momentary The System Configuration Group contains the Account Number, Swinger Count, Keyswitch, Easikey, Momentary Selection: Custom Idle Text, and Custom Service Text prompts. 0 Easikey 1 Momentary 1 Account Number Refer to the Installation Guide for instructions on Default: 0000 connecting a momentary keyswitch to a point. 0 to 9, B to F Selection: This contr

Summary of the content on the page No. 6

2000 Series | Program Entry Guide | 1.0 System Configuration EN | 6 6 Custom Service Text Default: Blank A to Z, 0 to 9, Selection: ! # , . - / : < > The system displays the text you enter here in the second line of the keypad display when ever the first line reads, CALL FOR SERVICE. You can enter the phone number for your service department as the Custom Service Text. Up to 15 Seconds for Text to Load: It can take up to 15 seconds for the custom text you program here to appear i

Summary of the content on the page No. 7

2000 Series | Program Entry Guide | 2.0 Phone EN | 7 Table 1: Phone Routing Set to No 2.0 Phone The Phone Group contains prompts that configure the Attempt Phone Number system for dialing and sending reports on the 1 Phone Number 1 telephone line. 2 Phone Number 1 1 DTMF Dialing 3 Phone Number 2 4 Phone Number 2 Default: Yes 5 Phone Number 1 Selection: Yes, No 6 Phone Number 2 7 Phone Number 1 0 No 8 Phone Number 2 1 Yes 9 Phone Number 1 When DTMF Dialing is set to Yes,

Summary of the content on the page No. 8

2000 Series | Program Entry Guide | 2.0 Phone EN | 8 5 Fire Route 8 Restoral Route Default: Local Default: Local Local, Phone 1 only, Phone 2 only, Local, Phone 1 only, Phone 2 only, Selection: Selection: Both Both Local 0 Local 0 Phone 1 only 1 Phone 1 only 1 Phone 2 only 2 Phone 2 only 2 Both 3 Both 3 Reports: Fire Alarm Reports from points or ABC Reports: keys. • Restoral Reports from Fire and Non-Fire points combined 6 Non-Fire Route • RF Battery Restorals Default: Local

Summary of the content on the page No. 9

2000 Series | Program Entry Guide | 2.0 Phone EN | 9 11 Cancel Route 13 Sys Trbl Route Default: Local Default: Local Local, Phone 1 only, Phone 2 only, Local, Phone 1 only, Phone 2 only, Selection: Selection: Both Both Local 0 Local 0 Phone 1 only 1 Phone 1 only 1 Phone 2 only 2 Phone 2 only 2 Both 3 Both 3 Reports: Cancel Reports Reports: • RAM Access OK Reports (successful connection 12 Sys Trbl Route to a remote programmer) Default: Local • Comm Restoral Reports (successful

Summary of the content on the page No. 10

2000 Series | Program Entry Guide | 2.0 Phone EN | 10 15 Test Route Default: Local Local, Phone 1 only, Phone 2 only, Selection: Both Local 0 Phone 1 only 1 Phone 2 only 2 Both 3 Reports: • Test Reports • Service Start (stand-by pin locked down, installer code entered.) • Service Stop (standby-by pin unlocked. The control panel only sends a Service Stop Report if a Service Start Report was transmitted). Bosch Security Systems | 7/05 | 35114F

Summary of the content on the page No. 11

2000 Series | Program Entry Guide | 3.0 Reports EN | 11 3 Restricted O/C 3.0 Reports Default: No 1 O/C Rpts – All On Yes, No Selection: Default: No 0 No Selection: Yes, No 1 Yes 0 No Set the Restricted O/C prompt to Yes. The system only sends Opening Reports when the user turns the 1 Yes system off after an alarm. The system attaches an If you set the O/C Rpts-All On prompt to Yes, the AFTER ALARM message to the Modem II system transmits Closing Reports to the receiver Openi

Summary of the content on the page No. 12

2000 Series | Program Entry Guide | 3.0 Reports EN | 12 If the system is on with No Delay, alarm output at 6 Restoral Rpts Terminals 4 and 5 follows the alarm delay programmed here. The alarm sounds at the keypad Default: No without delay. No, Yes, Delay Selection: When mixing Delay Alarm points (Digit 2 set for 7 or 8), with No Delay Alarm points (Digit 2 set for 5, 0 No 6, or 9), the alarm output follows the programmed alarm delay if Delay Alarm points are faulted first. 1 Yes

Summary of the content on the page No. 13

2000 Series | Program Entry Guide | 3.0 Reports EN | 13 When set to Buzz, Report the system flashes the OK light at the keypad, sounds the trouble tone, and sends an AC Fail Report to the receiver. When set to Buzz, Tag-Along Rpt the system flashes the OK light and sounds the trouble tone at the keypad after 60 seconds. It sends an AC Fail Report to the receiver as a tag along with all reports sent to the receiver until AC restores. When set to No Buzz, Report the system flashes the

Summary of the content on the page No. 14

2000 Series | Program Entry Guide | 3.0 Reports EN | 14 Notes: Bosch Security Systems | 7/05 | 35114F

Summary of the content on the page No. 15

2000 Series | Program Entry Guide | 4.0 Receiver EN | 15 4.0 Receiver 4.1 Modem Reports 1 Rcvr Format Default: Modem Modem, Pulse Selection: 0 Pulse 1 Modem Set Rcvr Format to Modem to transmit reports in Modem II format with its advanced reporting capabilities. You need firmware revision 8.00 or greater installed in your D6500 Receiver. Table 2 shows the reports available. The D6500 line card ack tone table must contain “Modem II for D9112.” Refer to the 6500: Line Program En

Summary of the content on the page No. 16

2000 Series | Program Entry Guide | 4.0 Receiver EN | 16 Table 2: continued Modem II Report Description Closing Report when passcode is not used. Refer to the Passcode Rquired prompt in Section CLOSING REPORT 15.0 Passcodes. Using a Keyswitch or a remote programmer also sends this Closing Report with no user ID. Closing Report with user ID for users 1 to 8. CLOSING REPORT ID 001 (-008) Communication Failure event. Refer to Phone 1, Phone 2 in Section 2.0 Phone. COMM FAIL PHO

Summary of the content on the page No. 17

2000 Series | Program Entry Guide | 4.0 Receiver EN | 17 Table 2: continued Modem II Report Description Point 1 to 24 bypassed. Points can be bypassed from the keypad or from a remote POINT BYPASS POINT 001 (-024) programmer. Bypass Reports are only sent when Opening and Closing Reports are enabled in Section 6.0 Open/Close. Normal remote programmer session termination. RAM ACCESS OK Remote programmer made connection with control panel, but passcode was incorrect, or call RAM A

Summary of the content on the page No. 18

2000 Series | Program Entry Guide | 4.0 Receiver EN | 18 4.2 Pulse Report Groups If you select the Pulse Format you need to set the report code for each report group. Pulse 4x2 reports consist of a four-digit account number, a one-digit report group code, and a one-digit point or User ID number. For example, a control panel with the Account Number prompt set to 1213, the Rcvr Format prompt set to pulse, the Fire Group prompt set to 3, and Point 1 programmed as a Fire point would send the

Summary of the content on the page No. 19

2000 Series | Program Entry Guide | 4.0 Receiver EN | 19 3 Non-Fire Group 7 Opening Group Default: 0 Default: 0 Selection: 0 to 9, B to F Selection: 0 to 9, B to F 1 to 8 Non-Fire alarm from Points 1 to 24. Opening Report when keyswitch is 0 used, or Part On No Delay, or Part On 9 or 0 Non-Fire alarm from key A, B, or C. with delay. Refer to Section 7.0 ABC Keys. Opening Report with User ID for users 1 to 8 There are no Pulse Format versions of 1 to 8. the Modem II Alarm recent C

Summary of the content on the page No. 20

2000 Series | Program Entry Guide | 4.0 Receiver EN | 20 10 Sys Res Group Default: 0 Selection: 0 to 9, B to F 1 Successful connection to a remote programmer. 2 Not used. 3 Control panel reset with the stand-by switch (refer to the Installation Guide) or a remote programmer. 4 Not used. 5 Not used. 6 Not used. 7 Reports missing or low battery restored. 8 Restored AC power. 9 Communication Restoral event for Phone 1. B Communication Failure event for Phone 2. C RF tamper rest


Alternative user manuals
# User manual Category Download
1 Bosch Power Tools DSDA ISCSI DISK ARRAY SERIES DSA-N2B20 User manual Home Security System 24
2 Bosch Power Tools LBB 1961 User manual Home Security System 18
3 Bosch Power Tools MIC400 User manual Home Security System 3
4 Bosch Power Tools MIC440 User manual Home Security System 2
5 Bosch Power Tools MIC412 User manual Home Security System 2
6 Bosch Power Tools DSDA ISCSI DISK ARRAY SERIES DSA-N2B50 User manual Home Security System 1
7 Bosch Power Tools DSDA ISCSI DISK ARRAY SERIES DSA-S5B50 User manual Home Security System 1
8 3Com 1000BASE-T-GBIC User manual Home Security System 0
9 Sony BRCSDP12 User manual Home Security System 3
10 3Com TECHD-0000000122 User manual Home Security System 1
11 Sony SSC-M354 User manual Home Security System 3
12 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
13 Sony SNC-RX SNC-CS50 User manual Home Security System 4
14 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
15 Sony CD-7226 User manual Home Security System 1