AMX Metreau Entry Communicator with Display MET-ECOM-D user manual

User manual for the device AMX Metreau Entry Communicator with Display MET-ECOM-D

Device: AMX Metreau Entry Communicator with Display MET-ECOM-D
Category: Home Security System
Manufacturer: AMX
Size: 4.08 MB
Added : 6/16/2013
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for AMX Metreau Entry Communicator with Display MET-ECOM-D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with AMX Metreau Entry Communicator with Display MET-ECOM-D.

For your convenience

If looking through the AMX Metreau Entry Communicator with Display MET-ECOM-D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual AMX Metreau Entry Communicator with Display MET-ECOM-D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual AMX Metreau Entry Communicator with Display MET-ECOM-D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
AMX Metreau Entry Communicator with Display MET-ECOM-D User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual AMX Metreau Entry Communicator with Display MET-ECOM-D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to AMX Metreau Entry Communicator with Display MET-ECOM-D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operation/Reference Guide

Metreau Entry Communicators
MET-ECOM Metreau Entry Communicator
MET-ECOM-D Metreau Entry Communicator with Display
Last Revised: 12/04/2008
Voice and Video Communication Systems

Summary of the content on the page No. 2

AMX Limited Warranty and Disclaimer This Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partner which include AMX Dealers, Distributors, VIP’s or other AMX authorized entity. AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the

Summary of the content on the page No. 3

Table of Contents Table of Contents Metreau Entry Communicators ...........................................................................1 Overview .................................................................................................................. 1 Front Components .......................................................................................................... 2 Rear Components............................................................................................

Summary of the content on the page No. 4

Table of Contents Installing the Metreau Entry Communicator.................................................................. 27 Using Zero Configuration .................................................................................29 Overview ................................................................................................................ 29 Bonjour (Zero-Configuration) Client........................................................................ 29 Connecting In a Network Wi

Summary of the content on the page No. 5

Table of Contents Programming ....................................................................................................51 Overview ................................................................................................................ 51 SEND_COMMANDs................................................................................................ 51 Touch Panel Intercom Commands ................................................................................. 51 RTP, RTCP Vide

Summary of the content on the page No. 6

Table of Contents Setup page.................................................................................................................... 76 Someone At The Door page ......................................................................................... 77 Creating Popup Pages ............................................................................................ 78 Door Answer Call popup page ..................................................................................... 78

Summary of the content on the page No. 7

Metreau Entry Communicators Metreau Entry Communicators Overview The Metreau Entry Communicators (FIG. 1) can be placed at entry points of homes, condos and hotels to provide audio/video communications with anyone at a door or gate - all over IP. Any AMX Modero intercom-enabled touch panel can interface with the Entry Communicator and allow residents to open doors, gates and more. FIG. 1 Metreau Entry Communicators There are two variations within the Metreau Entry Communicator device family

Summary of the content on the page No. 8

Metreau Entry Communicators Front Components The front components of the Metreau Entry Communicators are indicated in FIG. 2: OLED display (MET-ECOM-D only) Video Camera Speaker Dual Color LED Status Bar Pushbutton (Doorbell) Microphone FIG. 2 Metreau Entry Communicators - Front Components 2 Metreau Entry Communicators

Summary of the content on the page No. 9

Metreau Entry Communicators Rear Components The rear components of the Metreau Entry Communicators are indicated in FIG. 3: Camera Viewing Angle Adjustment Mounting Slots (2 on each side) ID/Reset pushbutton STATUS (green LED) Ethernet Connection 2 Multi-Purpose I/Os (5V) 2 Low Voltage Relays (1A Contact) Mounting Clip FIG. 3 Metreau Entry Communicators - Rear Components Product Specifications - MET-ECOM MET-ECOM Specifications Power: • PoE powered – no local Power Supply needed • IEEE 802.3

Summary of the content on the page No. 10

Metreau Entry Communicators MET-ECOM Specifications (Cont.) Microphone: • -40 dB sensitivity, built-in echo cancellation (telephone quality) • Full duplex communication • VoIP Telephony Rear Panel Components: • Camera Viewing Angle Adjustment • Ethernet Port - 10/100 Ethernet with PoE. LEDs show communication activity, connection status, speeds, and mode information: SPD (speed) - Green LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. L/A (link/act

Summary of the content on the page No. 11

Metreau Entry Communicators Product Specifications - MET-ECOM-D MET-ECOM-D Specifications Power: • PoE powered – no local Power Supply needed • IEEE 802.3af Compliant Front Panel Components: • OLED Display • Integrated Color Video Camera • Speaker • Dual Color LED Status Bar: (Yellow/ Red) can be used to provide feedback, to attract attention for action, or as general indicator. • Pushbutton (Doorbell) • Microphone OLED Display: • 4-bit Gray Scale • 1.6” Diagonal Display • 180° Viewing Angle

Summary of the content on the page No. 12

Metreau Entry Communicators MET-ECOM-D Specifications (Cont.) Operating Environment: 32° to 104° F (0° to 40° C) Mounting: The MET-ECOM-D is installed in several ways: • 4 screws for hard surface mounting • 2 expansion clips for pressure mounting • Using the optional Surface Mount Box Colors Available: • Black MET-ECOM-BK (FG2408-01-BK) • White MET-ECOM-WH (FG2408-01-WH) • Polished Brass MET-ECOM-PB (FG2408-01-PB) • Antique Brass MET-ECOM-AB (FG2408-01-AB) • Stainless Steel MET-ECOM-SS (FG2408-0

Summary of the content on the page No. 13

Positioning the Camera Positioning the Camera Overview The camera on the Metreau Entry Communicators provides a symmetrical 42° viewing angle, and by default the camera is centered. The Metreau Entry Communicators feature a Camera Viewing Angle Adjustment slider on the rear panel of the unit that allows you to adjust the viewing angle horizontally from -15° to 15°. FIG. 4 indicates the viewing range of the integrated camera in the Metreau Entry Communicators. mounting surface Camera 42° (rear

Summary of the content on the page No. 14

42° Positioning the Camera Top view when camera is centered at 0° 42° LR Camera Viewing Angle Adjustment slider (default) Camera Top view when camera is facing left at 15° LR Camera Top view when camera is facing right at 15° LR Camera FIG. 5 MET-COM-D Camera: Left and Right Viewing Range 8 Metreau Entry Communicators 42°

Summary of the content on the page No. 15

Wiring and Connections Wiring and Connections Overview To avoid any damage to the electronic component, installation must be performed in an ESD safe environment. The installation section addresses the mounting and wiring of the Metreau Entry Communicators. After you have completed the installation you must consult the Using the Configuration Manager section of the Metreau Entry Communicators Operation/Reference Guide (available online at www.amx.com). Additionally, consider the location of y

Summary of the content on the page No. 16

Wiring and Connections Ethernet 10/100 Base-T RJ-45 Wiring Configuration The table below describes the pinouts, signals, and pairing for the Ethernet 10/100 Base-T connector and cable. The Ethernet cable connection is illustrated in FIG. 7. Ethernet Pinouts and Signals Pin Signals Connections Pairing Color 1 TX + 1 --------- 1 1 --------- 2 White-Orange 2 TX - 2 --------- 2 Orange 3 RX + 3 --------- 3 3 --------- 6 White-Green 4 no connection 4 --------- 4 Blue 5 no connection 5 -----

Summary of the content on the page No. 17

Wiring and Connections Input/Output (I/O) Port: Connections and Wiring The I/O port responds to either switch closures, voltage level (high/low) changes, or it can be used for logic-level outputs. A contact closure between the GND and an I/O port is detected as a Push. When used for voltage inputs, the I/O port detects a low signal (0 - 1.5 VDC) as a Push, and a high signal (3.5 - 5 VDC) as a Release (this IO port uses 5V logic but can handle up to 12V without harm). When used for outputs

Summary of the content on the page No. 18

Wiring and Connections Ferrite Installation (Required) Metreau Entry Communicators comes with a Cat5 Suppression Ferrite that must be clipped around the Ethernet cable, inside the wall box (no tools required). 1. Release the latch to open 2. Insert the Cat5 cable 3. Installation complete. the plastic enclosure. and close the enclosure. FIG. 8 Installing the CAT5 Suppression Ferrite When positioning the Ferrite clip inside the wall box, place the bottom of the clip flat against the back insi

Summary of the content on the page No. 19

Wiring and Connections System Diagram FIG. 10 provides a basic NetLinx system diagram using Metreau Entry Communicators: NetLinx Master MVP-8400i MVP-5200i NXA-ENET24PoE NXA-WAP250G PS-POE-AF NXD-1000Vi NXD-700Vi MET-ECOM-D MET-ECOM FIG. 10 Metreau Entry Communicators - System Diagram System Diagram - Intercom The following system diagram (FIG. 11) illustrates an AMX system using Metreau Entry Communicators with both wired and wireless touch panels: FIG. 11 Intercom System Diagram 13 Metrea

Summary of the content on the page No. 20

Wiring and Connections 14 Metreau Entry Communicators


Alternative user manuals
# User manual Category Download
1 AMX Metreau Entry Communicator with Display MET-ECOM-DNS-B User manual Home Security System 2
2 3Com 1000BASE-T-GBIC User manual Home Security System 0
3 Sony BRCSDP12 User manual Home Security System 3
4 3Com TECHD-0000000122 User manual Home Security System 1
5 Sony SSC-M354 User manual Home Security System 3
6 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
7 Sony SNC-RX SNC-CS50 User manual Home Security System 4
8 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
9 Sony CD-7226 User manual Home Security System 1
10 Sony Ssc-M383 User manual Home Security System 6
11 Sony Snc Df50n User manual Home Security System 1
12 Sony SNC-RX SNC-RZ50 User manual Home Security System 20
13 Sony BLUETOOTH MEX-BT2500 User manual Home Security System 10
14 4XEM IPCAMW40 User manual Home Security System 1
15 ABC Office 24501 User manual Home Security System 0