Toshiba LF232*F user manual

User manual for the device Toshiba LF232*F

Device: Toshiba LF232*F
Category: Home Safety Product
Manufacturer: Toshiba
Size: 0.45 MB
Added : 11/16/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toshiba LF232*F. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toshiba LF232*F.

For your convenience

If looking through the Toshiba LF232*F user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toshiba LF232*F on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toshiba LF232*F to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toshiba LF232*F User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toshiba LF232*F but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toshiba LF232*F. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


LF502/LF232*F
Electromagnetic Flowmeter for
6” to 24”

Partially-filled Pipes
(150 to 600 mm )


Introduction
The LF502 electromagnetic flowmeter uses Faraday’s
Law of electromagnetic induction in the same way as
conventional electromagnetic flowmeters to measure
the flow rate. Position of electrodes in the LF502 is so
designed that it can be used even in a partially-filled
pipe to measure the flow rate.
Improved functional magnetic field distribution
technique enables a high

Summary of the content on the page No. 2

TIC-LF502A ■ Model LF232*F converter Required straight pipe length: Input signals 10D minimum on upstream side and 5D minimum on downstream side Analog signal — the voltage signal from detector, Note: D is a nominal meter size. proportional to process flow rate. Fluid conductivity: 100µS/cm minimum Digital input DI (opt.) th Fluid temperature: 32 to 131 °F (0 to 55 °C ) (added when 9 digit of specification code is ”3”) Voltage level: High level 20 to 30 V dc Ambient temperature:

Summary of the content on the page No. 3

TIC-LF502A independently) Parameter settings—Parameters can be set as follows In the case of DO1 •IR Switches: Various parameters can be set without Pulse rate: 3.6 to 3,600,000 pulses/h opening the converter housing using 4 infrared Pulse width:Settable within the range of 0.3 to switches (password can be set) 500ms •Zero adjustment: Zero point adjustment can be In the case of DO2 started by pressing the switch in the converter. Pulse rate: 3.6 to 360,000 pulses/h •Digital comm

Summary of the content on the page No. 4

TIC-LF502A Installation ■ ■ Dimensions Dimensions Separate type LF502 (Meter size 10” to 24”) Separate type LF502 (Meter size 6” and 8”) Unit: inch (mm) Unit: inch (mm) 3.46 (88) 4.96 (126) 4.96 (126) 3.46 (88) 1.42 (36) 1.57 (40) 5.63 (143) 1.42 (36) 5.63 (143) 1.57 (40) 11.81(300) Roll-prevention base Figure 4. Detector Dimensions for Meter Sizes Figure 3. Detector Dimensions for Meter Sizes 10” (250 mm) to 24” (600 mm) 6” (150 mm) and 8” (200 mm ) See the follow

Summary of the content on the page No. 5

TIC-LF502A ■ Dimensions 9.33 (237) Installation method 4- φ12 hole 据付方法 6.10 (155) 8.74 (222) 据付けは、パネル(壁面)取付けか 2.91 (74) パイプ取付けで行います。 指定された取付用ボルト・ ナットが付 属します。 In the case of 2B pipe installation 2B パ イプ取 付け の場合 M10 U ボルト M10 U bolts 2B(50mm)パイプ Signal cable ground Output cable ground パ ネル取 付穴加 工寸 法 Power supply cable ground 11 to 12 φhole 2.91 (74) 11~12φ 穴 74 (4ヵ所) 4 places Grounding terminal 2.99 (76)

Summary of the content on the page No. 6

TIC-LF502A ■ External Connections Terminal box Power supply Ⅳ wire 2 (CVV) 5.5mm or more Power supply Grounded with 100 Ω or less ground resistance Current output (4 to 20mA) Digital input 2 (opt.) Thick walled steel conduit Digital input 1 (opt.) (20 to 30 Vdc) Digital output 4 (opt.) Digital output 3 (opt.) Digital output 2 (opt.) Detector Signal cable Digital output (2-wire shielded hard-rubber sheathed cable) Excitation

Summary of the content on the page No. 7

TIC-LF502A ■ About establishment environment ■ Piping Precautions Do not store or install the flowmeter: (1) Flange connection • Where there is direct sunlight. The flowmeter has upstream and downstream • Where excessive vibration or mechanical shock flanges on the ends of detector pipe. Connect occurs. these flanges with the flanges on both sides of • Where high temperature or high humidity pipeline bore using connection bolts after conditions exist. inserting a gasket between th

Summary of the content on the page No. 8

TIC-LF502A Table 1. Specification Code for LF502 detector Model Specification Code Size Description 1 2 3 4 5 6 7 8 9 10 11 12 A B L F 5 0 2 LF502 Electromagnetic flowmeter Meter size K 6" (150mm ) - L 8" (200mm ) - M 10" (250mm ) - N 12" (300mm ) - P 14" (350mm ) - Q 16" (400mm ) - R 20" (500mm ) - S 24" (600mm ) - A Standard Connec


Alternative user manuals
# User manual Category Download
1 Toshiba Electromagnetic Flowmeter LF470/LF612 User manual Home Safety Product 5
2 Sony HVL-F5DF User manual Home Safety Product 2
3 Sony HVL-HFL1 User manual Home Safety Product 6
4 Sony HVL-FDH2 User manual Home Safety Product 3
5 ACDelco LG08 User manual Home Safety Product 3
6 Adaptec 2000 Series Drive-Thru Timer System 2+2/386 User manual Home Safety Product 1
7 American Dynamics 1461 User manual Home Safety Product 1
8 AMX Video Sync Sensor VSS2 User manual Home Safety Product 0
9 AOSafety Beyond The Standard Eyewear Lens User manual Home Safety Product 1
10 AOSafety Eye Gear Lexa User manual Home Safety Product 0
11 AOSafety Eye Gear Nassau Vibrance User manual Home Safety Product 1
12 AOSafety GoggleGear Dust User manual Home Safety Product 1
13 AOSafety Nassau Rave ANSI Z87.1 User manual Home Safety Product 13
14 AOSafety Eyeware Zora 32150 User manual Home Safety Product 1
15 AOSafety Polarized Eyewear GlareX User manual Home Safety Product 1