Toshiba LF414 user manual

User manual for the device Toshiba LF414

Device: Toshiba LF414
Category: Automobile Parts
Manufacturer: Toshiba
Size: 4.19 MB
Added : 11/7/2014
Number of pages: 58
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toshiba LF414. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toshiba LF414.

For your convenience

If looking through the Toshiba LF414 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toshiba LF414 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toshiba LF414 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toshiba LF414 User manual - Online PDF
Advertisement
« Page 1 of 58 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toshiba LF414 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toshiba LF414. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



6F8A0870






ELECTROMAGNETIC FLOWMETER DETECTOR




MODEL LF414



INSTRUCTION MANUAL


























NOTES

Before using the equipment, please read this manual carefully and understand the

contents, and then use the equipment correctly.


• NEVER attempt to operate the equipment in any ways that are not described in this
instruction manual.

• After reading this manual, store it with care in a place where it can be referred

Summary of the content on the page No. 2

6F8A0870 NOTICE We thank you very much for your purchase of our LF414 series electromagnetic flowmeter detector. Integral type LF414/LF600F, LF414/LF610F Separate type detector LF414 This instruction manual describes the notes on using an electromagnetic flowmeter detector, installation, configuration and maintenance. It is intended for the personnel in charge of installation, operation and maintenance. To use this product properly and safely, read this manual (6F8A0870) caref

Summary of the content on the page No. 3

6F8A0870 SAFETY PRECAUTIONS Safety signs and labels affixed to the product and/or described in this manual give important information for using the product safely. They help prevent damage to property and obviate hazards for persons using the product. Make yourself familiar with signal words and symbols used for safety signs and labels. Then read the safety precautions that follow to prevent an accident involving personal injury, death or damage to property. Explanation of signa

Summary of the content on the page No. 4

6F8A0870 SAFETY PRECAUTIONS Safety Precautions for Installation and Wiring WARNING Do not disconnect while circuit is live unless location is known to be nonhazardous. Live part of electric circuit or a high temperature department can cause explosion. DON’T Do not modify or disassemble the enclosure. Strength degradation and defects of enclosure can cause explosion. DON’T Do not use parts of other products. Protective performance degradation for hazardous location can ca

Summary of the content on the page No. 5

6F8A0870 SAFETY PRECAUTIONS (continued) Safety Precautions for Installation and Wiring CAUTION Install a switch and fuse to isolate the Use an appropriate device to carry and install LF414/LF600F, LF610F and LF414 from the LF414/LF600F, LF610F and LF414. mains power. Power supply from mains power If this product falls to the ground, can cause electric shock or injury, or malfunction of or damage circuit break-down. to the product, can be caused. DO DO Turn off mains

Summary of the content on the page No. 6

6F8A0870 SAFETY PRECAUTIONS (continued) Safety Precautions for Maintenance and Inspection CAUTION Do not conduct wiring work with wet hands. Do not conduct wiring work when power is applied. Wet hands may result in Wiring while power is applied can electric shock. cause electric shock. DON’T DON’T Do not use a fuse other than the one Do not touch the LF414/LF600F, LF610F and specified. LF414 main body when high temperature fluid is being measured. Using a fuse other

Summary of the content on the page No. 7

6F8A0870 Handling Precautions To obtain the optimum performance from the LF600F, LF610F, LF602F and LF612F converter for years of continuous operation, observe the following precautions. (1) Do not store or install the flowmeter in: ・Places where there is direct sunlight. ・Places where there is snow and ice Infrared switches may not function correctly. ・Places where excessive vibration or mechanical shock occurs. ・Places where high temperature or high humidity conditions obtain.

Summary of the content on the page No. 8

6F8A0870 Handling Precautions (continued) (5) If the inside of the converter and detector's terminal box are wetted or humidified, it may cause insulation deterioration, which can result in fault or noise occurrence. So do not conduct wiring in the open air on rainy days. Also, be careful not to wet down the converter and detector's terminal box even in the case of indoor wiring, and complete wiring work in a short period of time. (6) Observe the following precautions when yo

Summary of the content on the page No. 9

6F8A0870 Table of Contents SAFETY PRECAUTIONS ·····················································································2 Handling Precautions ······························································································6 1. Product Inspection and Storage ······································································9 1.1 Product Inspection ······················································································· 9 1.2

Summary of the content on the page No. 10

6F8A0870 1. Product Inspection and Storage 1.1 Product Inspection LF414 series electromagnetic flowmeter is shipped in a cardboard container filled with shock-absorbing materials. Open the package carefully and check as follows: Make sure the following items are included in the package. For the integral type (when a converter and detector are united) Electromagnetic flowmeter main unit --------------------------------- 1 unit Instruction manual----------------One each for t

Summary of the content on the page No. 11

6F8A0870 2. Overview The LF414/LF600F, LF414/LF610F and LF414 electromagnetic flowmeter can be use in the following hazardous (classified) locations. ClassⅠ, Division 2, Groups A, B, C and D, ClassⅡ, Division 2, Groups E, F and G ClassⅢ This product is a converter used for electromagnetic flowmeters that measure the volumetric flow rate of conductive fluid using Faraday's law of electromagnetic induction. You can bring out the functions of the converter when you place it in

Summary of the content on the page No. 12

6F8A0870 3. Names of Parts IMPORTANT The apparatus should not be provided with the cable connections. Please prepare yourself for the cable connections which could be used in Division2 hazardos li 3.1 Appearance 3.1.1 Appearance of LF414/LF600F, LF414/LF610F (1) Meter size of 1/2 inch (15mm) Integral For the detail of the converter, check the LF600F, LF610F converter's instruction manual. Terminal block cover Ground t

Summary of the content on the page No. 13

6F8A0870 (2) Meter size of 1inch (25mm) For the detail of the converter, check the LF600F, LF610F converter's instruction manual. Terminal block cover Ground terminal for converter Flow direction arrow Detector Ground terminal for detector Grounding ring Window for electrode Figure 3.1.2 Appearance of LF414/LF600F, LF610F Meter size 1 inch(25mm) - 12 -

Summary of the content on the page No. 14

6F8A0870 (3) Meter size of 1 1/2 to 4 inch (40 to 100mm) For the detail of the converter, check the LF600F , LF610F converter's instruction manual. Terminal block cover Ground terminal for converter Flow direction arrow Ground terminal for detector Detector Grounding ring Figure 3.1.3 Appearance of LF414/LF600F, LF610F Meter size 1 1/2 to 4 inch (40 to 100mm) - 13 -

Summary of the content on the page No. 15

6F8A0870 (4) Meter size of 6 and 8 inch (150 and 200mm) For the detail of the converter, check the LF600F, LF610F converter's instruction manual. Terminal block cover Lifting Lugs *Only 8 inch (200mm) Flow direction arrow provided. Ground terminal for converter Ground terminal for detector Grounding ring Detector Figure 3.1.1 Appearance of LF414/LF600F, LF610F Meter size 6 and 8 inch(150 an

Summary of the content on the page No. 16

6F8A0870 3.1.2 Appearance of LF414 (1) Meter size of 1/2 inch (15mm) Separate Excitation cable Signal cable Terminal Box Cover 3/4 - 14 NPT 3/4 - 14 NPT Terminal Box Flow direction arrow Detector Ground terminal for detector Grounding ring Window for electrode Figure 3.1.2 Appearance of LF414 Meter size 1/2inch(15mm) - 15 -

Summary of the content on the page No. 17

6F8A0870 (2) Meter size of 1inch (25mm) for Excitation cable for Signal cable Terminal Box Cover 3/4 - 14 NPT 3/4 - 14 NPT Terminal Box Flow direction arrow Detector Ground terminal for detector Grounding ring Window for electrode Figure 3.1.2 Appearance of LF414 Meter size 1 inch(25mm) - 16 -

Summary of the content on the page No. 18

6F8A0870 (3) Meter size of 1 1/2 to 4 inch (40 to 100mm) Excitation cable Signal cable 3/4 - 14 NPT Terminal Box Cover 3/4 - 14 NPT Terminal Box Flow direction arrow Detector Ground terminal for detector Grounding ring Figure 3.1.3 Appearance of LF414 Meter size 1 1/2 to 4 inch (40 to 100mm) - 17 -

Summary of the content on the page No. 19

6F8A0870 (4) Meter size of 6 and 8 inch (150 and 200mm) Excitation cable Signal cable Terminal Box Cover 3/4 - 14 NPT 3/4 - 14 NPT Terminal Box Lifting lugs Flow direction arrow *Only 8 inch (200mm) 矢印銘板 provided. Ground terminal for detector Grounding ring Detector Figure 3.1.4 Appearance of LF414 Meter size 6 and 8 inch(150 and 200mm) - 18 -

Summary of the content on the page No. 20

6F8A0870 3.2 Construction of the terminal blocks 3.2.1 Terminal Block Construction of LF414/LF600F, LF414/LF610F Type For details of the converter, check the LF600F, LF610Fconverter's instruction manual. Integral 3.2.2 Terminal Block Construction of LF414 Type Separate Signal cable terminal Excitation cable terminal Figure 3.2.2 Terminal Block of LF414 - 19 -


Alternative user manuals
# User manual Category Download
1 Toshiba GF632 User manual Automobile Parts 9
2 Toshiba LF470 User manual Automobile Parts 6
3 Toshiba LF404 User manual Automobile Parts 1
4 Toshiba LF516 User manual Automobile Parts 2
5 Toshiba LF502 User manual Automobile Parts 1
6 Toshiba TIC-LF414C User manual Automobile Parts 1
7 Toshiba LF434 User manual Automobile Parts 1
8 Toshiba LF400 User manual Automobile Parts 39
9 Toshiba LF494 User manual Automobile Parts 1
10 Toshiba LF600 User manual Automobile Parts 25
11 Toshiba LF546 User manual Automobile Parts 1
12 Toshiba LF600F User manual Automobile Parts 5
13 Toshiba LF602F User manual Automobile Parts 1
14 Toshiba GF630 User manual Automobile Parts 14
15 Toshiba LF414 User manual Metal Detector 8
16 Sony BP-GL95 User manual Automobile Parts 25
17 Sony BP-GL65 User manual Automobile Parts 2
18 Philips Epic 50PF9966 User manual Automobile Parts 3
19 Philips HTS3011 User manual Automobile Parts 2
20 Philips SDJ6040W User manual Automobile Parts 1