Konica Minolta Range7 user manual

User manual for the device Konica Minolta Range7

Device: Konica Minolta Range7
Category: Graphics Tablet
Manufacturer: Konica Minolta
Size: 2.59 MB
Added : 4/22/2014
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Konica Minolta Range7. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Konica Minolta Range7.

For your convenience

If looking through the Konica Minolta Range7 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Konica Minolta Range7 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Konica Minolta Range7 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Konica Minolta Range7 User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Konica Minolta Range7 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Konica Minolta Range7. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Non-contact 3D Digitizer



Instruction Manual
Read and understand all
instructions before using.

Summary of the content on the page No. 2

Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument. Denotes a sentence regarding a safety warning or note. Read the sentence carefully to ensure safe and correct use. Denotes a prohibited operation. The operation must never been performed. Denotes an instruction. The instruction must be strictly adhered to. Denotes an instruction. Disconnect the AC adapter from the AC outlet. Denotes a prohibited oper

Summary of the content on the page No. 3

Safety Precautions W h e n us i n g t hi s h a n d w a r e , t h e f o ll o w i n g p o i n t s mus t b e s t r i c t ly o b s e r v e d t o e ns ur e c o r r e c t an d s a f e us e . A f t e r y o u h a v e r e ad t hi s m a n u a l , k e e p i t i n a s a f e p l a c e w h e r e i t c a n b e r e f e r r e d t o a n y t i m e a q u e s t i o n a r i s e s . ( F ai lur e t o ad h e r e t o t h e f o ll o w i n g p o i n t s m a y r e s ul t i n d e a t h o r s e r i o us i n j ur y . ) WARN

Summary of the content on the page No. 4

Foreword About the packing materials contained in your product package • Please ensu re that you carefully keep the packing mate rials (corrugated cardboard, cushion materials, and plastic bags) contained in your product package. • The RANGE7/5 is a precision measuring instrument. If you transport the RANGE7/5 to our factory for the purpose of maintenance (repair , etc.), you should use the packing materials contained in the product package in order to minimize impact and shock dur

Summary of the content on the page No. 5

Laser Label Indication Warning and instruction labels about the laser RANGE7/5 Other warning label 3

Summary of the content on the page No. 6

About this Manual (Contents) This instruction manual provides the following contents about preparations for use of the RANGE7/5. • Precautions for Use • Part Names and Functions • System Configuration and Accessories • Setup Procedure for Measurement with the RANGE7/5 • RANGE7/5 Measuring Steps (Images) • Measuring Principle of the RANGE7/5 • RANGE7/5 Specifications and Accessories In this manual, illustrations of RANGE7 are used. The product name printed on the front side of RANGE5 is different

Summary of the content on the page No. 7

About the RANGE7/5 Standard accessories n System Diagram Optional accessories Light-receiving lens KONICA MINOLTA (TELE, WIDE) RANGE7 AC adapter Marker sheet trial pack AC power cord RA-A104 (T, W markers: 500 pcs each) Calibration chart RA-105 3D data processing software RANGE VIEWER USB Cable (5m) Calibration Calibration IF-A22 Personal computer sheet base Reverse engineering : Europe only (3m) (Commercially available) RA-A107 /inspection software IF-A18 RA-A106 Rapidform® TM TM XOV

Summary of the content on the page No. 8

Standard accessories Optional accessories KONICA MINOLTA RANGE5 AC adapter Marker sheet trial pack AC power cord RA-A108 (Marker: 500 pcs) Calibration chart RA-A105 3D data processing software RANGE VIEWER USB Cable (5m) Calibration IF-A22 Calibration sheet Personal computer base Reverse engineering : Europe only (3m) RA-A107 /inspection software (Commercially available) RA-A106 IF-A18 Rapidform® TM TM XOV / XOR Tripod set RA-A121 Platform set for Tripod Marker sheet W Measuring Stand

Summary of the content on the page No. 9

n Names of Parts and Functions 1) Carrying handle 3) Laser-emitting Window WARNING 2) Light-Receiving Lens A laser beam is emitted from this port. Do not stare directly into the laser beam. 4) Laser shutter 6) Platform mounting screw hole 5) Rubber sole 7) Power switch 8) AC adapter terminal Laser Label Indication (page 3) 9) USB port (T ype B) 1) Carrying handle Used to lift or carry the RANGE7/5. (Be sure to hold the RANGE7/5 body with both hands.) 2) Light-receiving lens Exchange t

Summary of the content on the page No. 10

55° (Unit: mm) n Dimensions 248 387.9 ø 35 9 197.7 ø61.5 57.7 ø66 ø74.7 57.7 292.4 8 ø15 111 189.6 9.1 20.8 141 48.3 199.6

Summary of the content on the page No. 11

Installation and Setup n Installation This section describes the RANGE7/5 installation procedures and precautions for installation. To install the RANGE7/5, you can use the following three methods: 1) Direct installation on a table or like surface (including a measuring table prepared by user) 2) Installation using tripod set (under optional accessories) 3) Installation using measuring stand set (under optional accessories) 1) Direct installation on table The RANGE7

Summary of the content on the page No. 12

3) Installation using the measuring stand set (under optional accessories) Mount the RANGE7/5 to the measuring stand platform (under optional accessories). NOTE • Before mounting the RANGE7/5, make sure that the measuring stand platform is properly mounted to the measuring stand. * For the procedure on how to mount the measuring stand platform to the measuring stand, refer to the instruction manual for the measuring stand set. • When using the measuring stand, tighten the lock lever for ea

Summary of the content on the page No. 13

n Setup To execute measurement using the RANGE7, mount an optimum lens depending on the measuring target size and the measuring distance, and install the RANGE7 at an optimum position relative to the measuring target. (No replacement lens for RANGE5.) The following is an example of the ordinary RANGE7/5 setup using the tripod setting (under optional accessories). RANGE7/5 Cable clamp Tripod Set Platform for Tripod Object AC adapter (100V AC main outlet with a grounding terminal) AC power co

Summary of the content on the page No. 14

This section describes the procedure for installing the RANGE7/5 properly, and completing the preparations for measurement. Make preparations according to the following procedures: 1) Installing the RANGE7/5. 2) Set the RANGE7/5 at a position relative to the proper target, and mount the lens suitable in question as the target of measure. (No replacement lens for RANGE5.) 3) Connect the AC adaptor to the RANGE7/5. 4) Connect the RANGE7/5 to a PC. 5) Turn ON the RANGE7/5 power

Summary of the content on the page No. 15

Changing of Lens (RANGE7 only) Set the RANGE7 at a position proper to the measuring target, and exchange the lens for an optimum one, depending on the measuring target size and the distance between the RANGE7 and the measuring target. NOTE When changing the lens, confirm that the lens number is the same number as the RANGE7 body. Memo RANGE7 needs to warm up for about 20 minutes after being switched ON. It is always possible to change lenses, but if the lens temperature is different from the m

Summary of the content on the page No. 16

3) Connecting the AC adaptor 1) Connect the AC cable to the AC adaptor for the RANGE7/5. 2) Insert the AC adaptor plug of the dedicated AC adaptor (AC-A324) to the AC adaptor connection terminal on the right of the RANGE7/5 rear panel. 3) Insert the AC cable plug connected to the AC adaptor to a 100 V AC main outlet. NOTE Insert the plug securely to the innermost position. 4) Connecting the RANGE7/5 to a PC 1) Insert the Type B plug of the dedicated USB cable to the USB port on the right o

Summary of the content on the page No. 17

5) Turning power on/off 1) Push the white power button in the upper right part of the rear panel of the RANGE7/5. A short beep sounds, the power is switched on, and the power button is lit yellow-green. Power button 2) Warming-up of the RANGE7/5 starts when the laser shutter is opened. Memo • RANGE7/5 needs to warm up for about 20 minutes after being switched ON. • While the RANGE7/5 is warming up, a message that the RANGE7/5 is now warming up will appear on the screen of RANGE VIEWER sof

Summary of the content on the page No. 18

n About Field Calibration The figure below shows an example of setting up the RANGE7/5 for calibration using the Calibration Set. Enough space is needed to spread out the sheet. 1280×430 mm RANGE7/5 Calibration chart Set the calibration chart in the position marked on the sheet for the lens being used. Calibration base Memo For RANGE5, place in the position off the WIDE lens. Calibration sheet Do not touch the front side of the chart with bare hands. If dirty, wipe the chart clean with a dr

Summary of the content on the page No. 19

Measuring Steps (Images) n Installation and Measurement (Image) Example of installation on Measuring Stand Set RA-A200 (optional accessory) Example of inst allat ion on T ripod Set RA-A121 (opt ional accessory) 17

Summary of the content on the page No. 20

n Shooting and Focusing (Image) n Scanning (Image) 18


Alternative user manuals
# User manual Category Download
1 Konica Minolta 7 User manual Graphics Tablet 2
2 Konica Minolta VI-9i User manual Graphics Tablet 3
3 Konica Minolta VIVID 9i User manual Graphics Tablet 4
4 Sony S User manual Graphics Tablet 7
5 Sony SGPT11 User manual Graphics Tablet 8
6 Agilent Technologies DC282 User manual Graphics Tablet 2
7 Agilent Technologies DP110 User manual Graphics Tablet 1
8 Agilent Technologies DC135 User manual Graphics Tablet 0
9 Agilent Technologies DC211 User manual Graphics Tablet 1
10 Agilent Technologies DC122 User manual Graphics Tablet 1
11 Agilent Technologies DP1400 User manual Graphics Tablet 2
12 Agilent Technologies DP106 User manual Graphics Tablet 1
13 Agilent Technologies DC152 User manual Graphics Tablet 1
14 Agilent Technologies DC252 User manual Graphics Tablet 1
15 Agilent Technologies DP212 User manual Graphics Tablet 1