Multiquip C-30HDNI user manual

User manual for the device Multiquip C-30HDNI

Device: Multiquip C-30HDNI
Category: Automobile Parts
Manufacturer: Multiquip
Size: 2.7 MB
Added : 8/3/2013
Number of pages: 136
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Multiquip C-30HDNI. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Multiquip C-30HDNI.

For your convenience

If looking through the Multiquip C-30HDNI user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Multiquip C-30HDNI on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Multiquip C-30HDNI to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Multiquip C-30HDNI User manual - Online PDF
Advertisement
« Page 1 of 136 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Multiquip C-30HDNI but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Multiquip C-30HDNI. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATION AND PARTS MANUAL
SERIES
MODEL C-30HDNI
CONCRETE PUMP
(PRECISION FUEL INJECTION)
UP TO S/N: 240601
Revision #7 (04/03/12)
To find the latest revision of this
publication, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.

Summary of the content on the page No. 2

PROPOSITION 65 WARNING PAGE 2 — MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12)

Summary of the content on the page No. 3

SILICOSIS/RESPIRATORY WARNINGS WARNING WARNING SILICOSIS WARNING RESPIRATORY HAZARDS Grinding/cutting/drilling of masonry, concrete, metal and Grinding/cutting/drilling of masonry, concrete, metal and other materials with silica in their composition may give other materials can generate dust, mists and fumes off dust or mists containing crystalline silica. Silica is a containing chemicals known to cause serious or fatal basic component of sand, quartz, brick clay, granite and injury or illness,

Summary of the content on the page No. 4

TABLE OF CONTENTS MAYCO C-30HDNI (PRECISION) COMPONENT DRAWINGS CONCRETE PUMP Nameplate and Decals....................................... 68-69 Compensator Piston Rod Assembly .................. 70-71 Proposition 65 Warning .............................................. 2 Connecting Rod - Drive Side Assembly ............. 72-73 Silicosis Warning ........................................................3 Rocker Assembly ............................................... 74-75 Table of Contents ......

Summary of the content on the page No. 5

PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Effective: st January 1 , 2006 Best Deal! Order via Internet (Dealers Only): If you have an MQ Account, to obtain a Username Order parts on-line using Multiquip’s SmartEquip website! and Password, E-mail us at: parts@multiquip. com. ■ View Parts Diagrams To obtain an MQ Account, contact your ■ Order Parts District Sales Manager for more information. ■ Print Specification Information Use the inte

Summary of the content on the page No. 6

C-30HDNI (PRECISION) PUMP — PUMP SPECIFICATIONS TABLE 1. C-30HDN PUMP SPECIFICATIONS Pn ump Type Reciprocating Pisto P* umping Rate Up to 25 cu. yds. per hour V) ertical Pumping Height Up to 150 ft. (45.73 m H* orizontal Pumping Distance 400 - 500 ft. (122 - 152 m) M) aximum Aggregate Size 1/2 in. minus (12.7 mm H. opper Capacity 6 cu. ft. etc 2" or 2-1/2" Material Hose (50.8 or 63.5 mm) W) eight 2,950 lbs. (1,338 Kg L) ube oil Box 7 Gallons (26.5 Liters Rd emote Control 125 ft. cable Standar 7.

Summary of the content on the page No. 7

C-30HDNI (PRECISION) PUMP — PUMP DIMENSIONS Figure 1. C-30HDNI Concrete Pump Dimensions MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12) — PAGE 7

Summary of the content on the page No. 8

C-30HDNI (PRECISION) PUMP — SAFETY MESSAGE ALERT SYMBOLS HAZARD SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! Potential hazards associated with operation of the pump will be Safety precautions should be followed at all times when operating referenced with Hazard Symbols which appear throughout this this equipment. Failure to read and understand the Safety manual, and will be referenced in conjunction with Safety Messages and Operating Instructions could result in injury to Message Alert Sym

Summary of the content on the page No. 9

C-30HDNI (PRECISION) PUMP — SAFETY MESSAGE ALERT SYMBOLS WARNING - ROTATING PARTS CAUTION - RESPIRATORY HAZARDS NEVER operate equipment with covers, or guards removed. Keep fingers, hands, ALWAYS wear approved respiratory hair and clothing away from all moving protection. parts to prevent injury. CAUTION - ACCIDENTAL STARTING CAUTION - SIGHT AND HEARING HAZARDS ALWAYS place the Engine ON/OFF switch ALWAYS wear approved eye and in the OFF position and remove the ignition hearing protection. key

Summary of the content on the page No. 10

C-30HDNI (PRECISION) PUMP — RULES FOR SAFE OPERATION ■ Whenever necessary, replace nameplate, operation and safety DANGER - Read This Manual! decals when they become difficult read. Failure to follow instructions in this manual may lead to serious ■ Manufacture does not assume responsibility for any accident injury or even death! This equipment is to be operated by due to equipment modifications. trained and qualified personnel only! This equipment is for ■ NEVER use accessories or attachments,

Summary of the content on the page No. 11

C-30HDNI (PRECISION) PUMP — RULES FOR SAFE OPERATION ■ CAUTION must always be observed while servicing this ■ A copy of this manual shall accompany the pump at all times. pump. Rotating parts can cause injury if contacted. ■ DO NOT use worn out hoses or couplings; inspect daily. ■ ALWAYS stored the pump in a clean, dry location out of the ■ DO NOT disconnect the hose couplings or nozzle while they reach of children. are under pressure. Relieve the pressure by manually ■ ALWAYS use extreme care

Summary of the content on the page No. 12

C-30HDNI (PRECISION) PUMP — RULES FOR SAFE OPERATION Maintenance Safety Emergencies ■ NEVER lubricate components or attempt service on a running ■ ALWAYS know the location of the nearest fire extinguisher machine. and first aid kit. Know the location of the nearest telephone. Also know the phone numbers of the nearest ambulance, ■ ALWAYS allow the machine a proper amount of time to cool doctor and fire department. This information will be before servicing. invaluable in the case of an emergenc

Summary of the content on the page No. 13

NOTES MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12) — PAGE 13

Summary of the content on the page No. 14

C-30HDNI (PRECISION) PUMP — TOWING GUIDELINES Towing Safety Precautions ■ Check wheel mounting lug nuts with a torque wrench. Torque wheel lug nuts as described in the "Lug Nut Torque CAUTION - Local Towing Regulations Requirements", Table 5. ■ Make sure brakes are synchronized and functioning properly. Check with your county or state safety towing regulations ■ Check tightness of suspension hardware (nuts and bolts). department before towing your concrete pump. ■ Avoid sudden stops and starts.

Summary of the content on the page No. 15

C-30HDNI (PRECISION) PUMP — TOWING GUIDELINES Figure 2 shown below illustrates the typical towing application that should be used when towing the pump. Figure 2. Towing Applications MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12) — PAGE 15

Summary of the content on the page No. 16

C-30HDNI (PRECISION) PUMP — TRAILER SAFETY GUIDELINES Trailer Safety Precautions The following list defines the major trailer components: 1. Fuel Cell – Provides an adequate amount of fuel for the CAUTION - General Trailer Safety equipment in use. Fuel cells must be empty when transport- ing equipment. ALWAYS make sure that the trailer is in good operating condi- tion. Check the tires for proper inflation and wear. Also check the 2. Frame Length – This measurement is from the ball hitch to wheel

Summary of the content on the page No. 17

C-30HDNI (PRECISION) PUMP — TRAILER SAFETY GUIDELINES Tires/Wheels/Lug Nuts Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched. CAUTION - General Trailer Safety DO NOT attempt to repair or modify a wheel. DO NOT install an inter-tube to correct a leak through the rim. If the rim is cracked, the air pressure in the inter-tube may cause pieces of the rim to e

Summary of the content on the page No. 18

C-30HDNI (PRECISION) PUMP — TRAILER SAFETY GUIDELINES Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1. Start all wheel lug nuts by hand. 2. Torque all lug nuts in sequence (Figure 4). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined

Summary of the content on the page No. 19

NOTES MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12) — PAGE 19

Summary of the content on the page No. 20

C-30HDNI (PRECISION) PUMP — OPERATION AND SAFETY DECALS Figure 5 display's the operation and safety decals as they appear on the concrete pump, should any of these decals become damaged or unreadable, contact the Multiquip Parts Department for a replacement set. Figure 5. Operation and Safety Decals PAGE 20 — MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12)


Alternative user manuals
# User manual Category Download
1 Multiquip LS600 User manual Automobile Parts 0
2 Multiquip MQ Power Whisperwatt 60HZ Generator DCA150USJ2 User manual Automobile Parts 3
3 Multiquip LT12D User manual Automobile Parts 5
4 Multiquip MTX80 User manual Automobile Parts 6
5 Multiquip DCA20SPXU2 User manual Automobile Parts 1
6 Multiquip LS60TD User manual Automobile Parts 0
7 Multiquip EM-70P User manual Automobile Parts 0
8 Multiquip CA4HC User manual Automobile Parts 1
9 Multiquip DCA220SSJ/SSJU User manual Automobile Parts 0
10 Multiquip DSGPULW User manual Automobile Parts 1
11 Multiquip CA4HM User manual Automobile Parts 1
12 Multiquip EM-70S User manual Automobile Parts 0
13 Multiquip G-55H User manual Automobile Parts 0
14 Multiquip HTXD6i User manual Automobile Parts 0
15 Multiquip LT12D50SA User manual Automobile Parts 0
16 Sony BP-GL95 User manual Automobile Parts 25
17 Sony BP-GL65 User manual Automobile Parts 2
18 Philips Epic 50PF9966 User manual Automobile Parts 3
19 Philips HTS3011 User manual Automobile Parts 2
20 Philips SDJ6040W User manual Automobile Parts 1