Manfrotto 203 user manual

User manual for the device Manfrotto 203

Device: Manfrotto 203
Category: Automobile Parts
Manufacturer: Manfrotto
Size: 0.29 MB
Added : 10/6/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Manfrotto 203. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Manfrotto 203.

For your convenience

If looking through the Manfrotto 203 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Manfrotto 203 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Manfrotto 203 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Manfrotto 203 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Manfrotto 203 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Manfrotto 203. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TELEDYNE
HASTINGS
INSTRUMENTS
INSTRUCTION MANUAL
201/203 SERIES
FLOW METERS/CONTROLLERS

Summary of the content on the page No. 2

Manual Print History The print history shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates. Addenda, which are released between revisions, contain important change information that the user should incorporate immediately into the manual. Addenda are numbered sequentially. When a new revision is created, all addenda associated with the previous revision of the

Summary of the content on the page No. 3

Table of Contents 1. GENERAL INFORMATION............................................................................................................................................ 4 1.1. FEATURES.................................................................................................................................................................... 4 1.2. SPECIFICATIONS.................................................................................................................

Summary of the content on the page No. 4

1. General Information The Hastings HFM-201/HFC-203 series Mass flow meter (HFM-201) and controller (HFC-203) are designed to accurately measure and control mass flow over the range of 30 slm to 500 slm, without corrections or compensations for gas pressure and temperature with an accuracy of better than ±1% from the mean (±2% FS for 500 slm). Hastings mass flow instruments do not require any periodic maintenance under normal operating conditions with clean gases. No damage will occur f

Summary of the content on the page No. 5

1.2. Specifications Accuracy ...........................................................................................................±1% full scale (F.S.) Repeatability ..............................................................................................................<±0.1% of F.S. Maximum operational pressure .........................................................................500 psi [3.45 MPa]. ...........................................................................

Summary of the content on the page No. 6

1.3. Optional 4-20 mA Current Output An option to the standard 0-5 VDC output is the 4-20 mA current output that is proportional to flow. The 4 - 20 mA signal is produced from the 0 - 5 VDC output of the flow meter. The current loop output is useful for remote applications where pickup noise could substantially affect the stability of the voltage output. The current loop signal replaces the voltage output on pin 6 of the “D” connector. The current loop may be returned to either the po

Summary of the content on the page No. 7

2. Installation and Operation This section contains the necessary steps to assist in getting a new flow meter/controller into operation as quickly and easily as possible. Please read the following thoroughly before attempting to install the instrument. 2.1. Receiving Inspection Carefully unpack the Hastings 201/203 series instrument and any accessories that have also been ordered. Inspect for any obvious signs of damage to the shipment. Immediately advise the carrier who delivered the

Summary of the content on the page No. 8

regulators and large internal diameter plumbing help to make the system more stable. The pressure drop between the regulator and the instrument due to line resistance should be minimized. The differential pressure across the unit should be less than 6” of H2O at maximum flow. There are two 8-32 threaded holes, 0.25” deep, located on the bottom of the base that can be used to secure it to a mounting bracket, if desired (screws provided). Other holes for special mounting can be added to th

Summary of the content on the page No. 9

If a valve override switch is not desired, the unit is ready for use at this time. If the override switch is desired, connect the center pin of a single pole, three-position switch with the center off position to pin 8. Connect +15VDC to one end of the switch, and -15VDC to the other end. This will result in the valve being full open when +15VDC is supplied to pin 8, off when -15VDC is supplied and auto-control when there is no connection to pin 8 (OPEN-AUTO-CLOSE). This setup will be adeq

Summary of the content on the page No. 10

B, it then becomes a variable reference voltage for flow controller B proportional to the flow rate of flow controller A. If the set point potentiometer of flow controller B is set at 50% of full scale, and the reference voltage from flow controller A is 4.00, then the command signal going to flow controller B would be 2.00 volts (4.00 volts x 50.0% = 2.00 volts). The flow of gas through flow controller B is then controlled at 4 slpm (2.00 volts/5.00 volts x 10 slpm = 4 slpm). The ratio o

Summary of the content on the page No. 11

2.6.8. Response to Command Changes The response of the control circuit to changes to the command signal is set at the factory for fast, stable response. Should it be necessary, the response is adjustable using the jumper labeled “JP4,” located in the center of PC-828. The fastest response to command changes is obtained when JP4 is covered by the jumper. This setup allows large overshoot and undershoot swings in the actual flow rate while the control circuit is establishing control at the

Summary of the content on the page No. 12

3. Theory of Operation This section contains an overall functional description of HFC Flow Controllers. Detailed schematics and parts lists can be found at the end of the manual in Section 6.0. In this section and other sections throughout this manual, when a power supply is mentioned, it is assumed that the customer has a Hastings Power Supply. These sections are not applicable if another type of power supply is used. 3.1. Overall Functional Description: The HFC Flow Controller consis

Summary of the content on the page No. 13

This signal is amplified by the meter circuitry until is 0-5.00 VDC. This 5 volt output is sent back to the power supply and to the flow meter circuitry, if applicable. At the power supply the 5 volt output is sent to the terminals on the back and to the decoding circuitry in the display which converts it to a 3-digit output. The controller circuitry utilizes the Command and the Flow voltages as input signals. The 0-5VDC command signal is subtracted from the 0-5VDC flow signal crea

Summary of the content on the page No. 14

3.5. Valve: At flow rates higher than 30 slm, two valves are used in parallel. A solenoid valve is used as a pilot valve to control a much larger pneumatic diaphragm valve. The pilot valve is an “automatic metering solenoid” valve. While most solenoids operate in either the fully open or fully closed state, the automatic metering solenoid valve is designed to control flow (see Figure 3.5). A spring, connected to the plunger assembly, holds a magnetic plunger tightly against an orifice

Summary of the content on the page No. 15

4. Maintenance This section contains service and calibration information. Some portions of the instrument are delicate. Use extreme care when servicing the flow controller. The potentiometer positions and the electrical components referred to in the troubleshooting section can be found in Section 6.0 on the electrical component layout drawing. 4.1. Authorized Maintenance With proper care in installation and use, the flow controller will require little or no maintenance. If maintenance

Summary of the content on the page No. 16

ACTION: Shut off gas supply and power supply. Remove cover and PC board from unit. Remove sensor assembly and examine. If sensor has evidence of plugging, clean or replace as applicable SYMPTOM: Flow controller oscillates. CAUSE: Flow controller not adjusted for the dynamics of the flow system. ACTION: Check upstream and downstream pressures. The gas supply regulator should not have excessive lockup when flow shuts off. Also ensure that there is not a large drop in pressure betwe

Summary of the content on the page No. 17

4) Set command to 100%. Adjust SPAN (R29) pot until the flow reference reads full scale flow (5.000 VDC). NOTE: Perform this step only if a calibrated reference flow meter is available. 5) Record flow meter and flow reference outputs for flow rates of 20%, 40%, 60%, 80% and 100%. 4.3.2. Miscellaneous adjustments Periodically, during normal operation, the ZERO should be checked and adjusted when required. If system parameters change, the RESPONSE pot may require a small adjustment for op

Summary of the content on the page No. 18

Orifice Changes: A) Determine the minimum expected upstream pressure (Pu) in PSI absolute and the maximum expected downstream pressure (Pd) in PSI absolute for full flow conditions. B) If Pu >2Pd, use formula 1; otherwise use formula 2. Where: Formula 1: Formula 2: 0.0014Q 0.0028 σQ D = D = ΔΡ • Ρd P μ σ D = Diameter in inches Q = Flow rate in standard liters per minute P = Pu - Pd in PSI Pu = Upstream pressure in PSIA Pd = Downstream pressure in PSIA σ = Specific g

Summary of the content on the page No. 19

STOCK NO. DESCRIPTION ..................................................................................AIR RANGE 28-13-190 Orifice 0.046...............................................................................................HFC-203 28-13-164 Orifice 0.086...............................................................................................HFC-203 28-13-163 Orifice 0.13.................................................................................................HFC-203

Summary of the content on the page No. 20

5. WARRANTY 5.1. Warranty Repair Policy Hastings Instruments warrants this product for a period of one year from the date of shipment to be free from defects in material and workmanship. This warranty does not apply to defects or failures resulting from unauthorized modification, misuse or mishandling of the product. This warranty does not apply to batteries or other expendable parts, or to damage caused by leaking batteries or any similar occurrence. This warranty does not apply to any in


Alternative user manuals
# User manual Category Download
1 Manfrotto 201 User manual Automobile Parts 0
2 Sony BP-GL95 User manual Automobile Parts 25
3 Sony BP-GL65 User manual Automobile Parts 2
4 Philips Epic 50PF9966 User manual Automobile Parts 3
5 Philips HTS3011 User manual Automobile Parts 2
6 Philips SDJ6040W User manual Automobile Parts 1
7 Philips SWA2151W User manual Automobile Parts 0
8 Philips Vortex Flow Meter F-2200 Series User manual Automobile Parts 3
9 A4 Tech. Sun StorageTekTM 4Gb FC Dual GbE HBA SG-XPCIE2FCGBE-E-Z User manual Automobile Parts 0
10 Aetna SATINELLE ICE HP6492 User manual Automobile Parts 0
11 Accel 140025 User manual Automobile Parts 15
12 Actron Cylinder Leakage Tester Kit 2509 User manual Automobile Parts 18
13 Actron 2501 User manual Automobile Parts 0
14 Actron Digital Multimeter CP7676 User manual Automobile Parts 28
15 Actron Global OBD II Scan Tool 9620 User manual Automobile Parts 59