Viking Access Systems Vehicular Gate Opener X-9 user manual

User manual for the device Viking Access Systems Vehicular Gate Opener X-9

Device: Viking Access Systems Vehicular Gate Opener X-9
Category: Garage Door Opener
Manufacturer: Viking Access Systems
Size: 1.28 MB
Added : 8/6/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Viking Access Systems Vehicular Gate Opener X-9. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Viking Access Systems Vehicular Gate Opener X-9.

For your convenience

If looking through the Viking Access Systems Vehicular Gate Opener X-9 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Viking Access Systems Vehicular Gate Opener X-9 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Viking Access Systems Vehicular Gate Opener X-9 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Viking Access Systems Vehicular Gate Opener X-9 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Viking Access Systems Vehicular Gate Opener X-9 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Viking Access Systems Vehicular Gate Opener X-9. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

revision BØ february 2007
vehicular
installation instructions and
gate operator
safety information
Viking Access Systems
T 800.908.0884 • F 949.753.1640
LISTED 18TC
-
631 Wald - Irvine, CA 92618
UL 325
X 9
UL 991
vikingaccess.com
CLASS I, CLASS II, CLASS III and CLASS IV

Summary of the content on the page No. 2

19.685" P PAR ARTS DIA TS DIAGRAM GRAM WARNING - For Installation By Qualified Personnel Only. Item Description Part No. 1 1 Cover, Plastic VAX9PC 2 Motor/Gear Unit VAX9 6 3 Chassis, Motor/Gear VAX9CH 7 4 Strain Relief VAX9ST 9 5 Arm Assembly, Articulated VAX9AA 8 6 Holder, Limit Switch 10 7 Limit Switch (2) VAX9LS 8 Cam, Limit Switch VAX9LCS 9 Terminal Block VAX9TB 2 10 Key Release VAX9KR 11 Thumb Screw VAX9TS 12 Positive Stop Extension VAX9PSE 11 (2) Weight 40 lb. 3 4 5 12 Overall Dimensions 1

Summary of the content on the page No. 3

T TABLE OF CONTENTS ABLE OF CONTENTS Parts Diagram/Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i Important Safety Information Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Important Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Maintenance/General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Terminolog

Summary of the content on the page No. 4

IIMPOR MPORT TANT SAFETY INFORMA ANT SAFETY INFORMATION TION WARNING - Not following these instructions may cause severe injury or death to persons. IMPORTANT SAFETY INSTRUCTIONS WARNING – To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operat

Summary of the content on the page No. 5

IIMPOR MPORT TANT SAFETY INFORMA ANT SAFETY INFORMATION TION WARNING - Not following these instructions may cause severe injury or death to persons. IMPORTANT INSTALLATION INSTRUCTIONS Continued 6. Controls intended for user activation must be located at least six feet (6’) away from any mov- ing part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a secu- rity feature to p

Summary of the content on the page No. 6

IIMPOR MPORT TANT SAFETY INFORMA ANT SAFETY INFORMATION TION WARNING - Not following these instructions may cause severe injury or death to persons. MAINTENANCE Remove the Power Harness from the Control Board (refer to page 17) • Clean and lubricate the turning pins and gate hinges using the recommended lubricant. • Check that all mounting hardware of the gate operator is properly tighten. • Ensure that the gate moves freely. • Check for corroded parts and replace if necessary. • Check the batte

Summary of the content on the page No. 7

T TERMINOLOGY ERMINOLOGY UL325 Gate Operator Classification GLOSSARY RESIDENTIAL VEHICULAR GATE OPERATOR CLASS I – A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith. COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II – A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family hous- ing unit (five or more single family units), hote

Summary of the content on the page No. 8

Fail Safe/Secure Obstruction Overlap Delay Charger Charger Center Safety UL Radio Sensor IIMPOR MPORT TANT SAFETY INFORMA ANT SAFETY INFORMATION TION Loop Loop Sensor Rec. Power Power WARNING - Not following these instructions may cause severe injury or death to persons. Low Battery Low Battery NOTE - This type of installation DOES NOT reverse the gate all the way back to its limits when the photo-beam min. MAX Motor Sensor Motor Sensor is obstructed. This installation is only to prote

Summary of the content on the page No. 9

Fail Safe/Secure Obstruction Overlap Delay Charger Charger Sensor Center Safety UL Radio Loop Loop Sensor Rec. Power Power Low Battery Low Battery min. MAX Motor Sensor Motor Sensor IIMPOR MPORT TANT SAFETY INFORMA ANT SAFETY INFORMATION TION Hold Open Mag. Timer Brake Lock Close Stop Open WARNING - Not following these instructions may cause severe injury or death to persons. N.C. COM Edge Sensor (contact sensor) Installation N.O. 3-Sided Edge Sensor 3-Sided Edge Sensor M Master/Slave

Summary of the content on the page No. 10

Fail Safe/Secure IIMPOR MPORT TANT SAFETY INFORMA ANT SAFETY INFORMATION TION WARNING - Not following these instructions may cause severe injury or death to persons. Audible Alarm Reset Switch Installation Manual Reset for the Audible Alarm UL325 standard requires an audible alarm to go off after two consecutive events detected by the primary entrapment protection of the gate operator (obstruction sensor). The audible alarm will continue to sound for 5 minutes or until a stop command gets actua

Summary of the content on the page No. 11

IIMPOR MPORT TANT INST ANT INSTALLA ALLATION INFORMA TION INFORMATION TION CAUTION - FOR USE WITH GATES OF A MAXIMUM OF 14 FT IN LENGTH AND 600 LBS. IN WEIGHT. WARNING - TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS: This is NOT a pedestrian gate operator Do NOT Install the gate operator to lift gates OPEN 14'-0" STOP CLOSE Control C Control ontrol Buttons B Buttons uttons 14’ maximum gate length Locate Control Buttons: 1. Within sight of the gate, 600 lb. 2. At a minimum height of

Summary of the content on the page No. 12

P PLAN OF INST LAN OF INSTALLA ALLATION - OPEN INSIDE TION - OPEN INSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. C: 23-1/2" Outside G: 4.33" Ref. H: Gate in Closed Position 2.55" A: 15-3/4" Max. Ref. 90° Opening F: 15-1/2" Min. Inside Gate in Open Position Figure A – 90° Opening G: 4.33" 7-1

Summary of the content on the page No. 13

P PLAN OF INST LAN OF INSTALLA ALLATION – OPEN OUTSIDE TION – OPEN OUTSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. Outside Gate in Open Position 90° C: 19-1/2" Gate in Closed Position A: 11-3/4" G: 4.33" Max. Ref. H: 2.55" Ref. Inside Figure C Open Outside Plan of Installation Note: Varying from

Summary of the content on the page No. 14

G GA ATE OPERA TE OPERATOR INST TOR INSTALLA ALLATION TION CAUTION - If mounting bar is not welded to a frame member that runs the full length of the gate, the gate operator may damage the gate. Do not weld the bar or backing plate to a few pickets. STEP 1 14.173" Check the integrity of the gate structure and 5.90" 5.90" 1.181" sufficiently sturdy such as pivot points are properly lubricated and surfaces are free of 3.937" rust. a) Remove the Motor/Gear Assembly from its Motor/Gear Chassis packa

Summary of the content on the page No. 15

G GA ATE OPERA TE OPERATOR INST TOR INSTALLA ALLATION TION STEP 4 Remount the geared motor on the chassis accordingly. STEP 5 Attach the Articulated Arms with the Positive Stop Extension to the Pivot Bracket and the Motor/Gear Assembly. NOTE - Additional holes are provided in the Pivot Bracket to assist with proper installation STEP 6 With the cover off, perform the Manual Release procedure as shown at the bottom of page 7. The gate can now be moved Check Operation Through Entire manually. Ra

Summary of the content on the page No. 16

G GA ATE OPERA TE OPERATOR INST TOR INSTALLA ALLATION TION Limit Switch Setup STEP 8 Additional Cam Mounting Holes A. Loosen the screws on the limit switch cams and position the cams to the desired locations. There are additional holes provided in case of a wide or tight angle of opening or closing. B. Move the gate manually and ensure that the limit switch gets actuated at the Tighten Clamping Limit Switch Screw Securely Holder desired open and closed position. The Before Adjusting Posi

Summary of the content on the page No. 17

NC N0 COM B B l l a u c e k G GA ATE OPERA TE OPERATOR INST TOR INSTALLA ALLATION TION Opening/Closing Setup: To have the gate operator slow down prior to reaching its limits use the following steps: 1. Setup the limit switches manually at the desired open and close position. 2. Allow the gate operator to run a full open and close cycle (from limit to limit) without interruption. Note: During the first full open and close cycle: The gate operator doesn’t slow down prior to reaching its limits. D

Summary of the content on the page No. 18

C CONTROL BO ONTROL BOX INST X INSTALLA ALLATION TION WARNING - If the control box is not mounted properly it may fall, causing damage and/or injury. The control box weight is approximately 40 lbs. Be sure that the substrate being mounted to and the fasteners being used are appropriate to support the weight of the control box. 1. Remove the control board mounting plate. The plate is held in the box by four screws. 15" Standard 17" Industrial 2. Position the control box in the desired place and

Summary of the content on the page No. 19

P N o e w u H e o t r t r a G l r o u n d d n u o r G h t r a E E ELECTRICAL INST LECTRICAL INSTALLA ALLATION TION Caution – Do not connect the power harness to the board until the installation is ready for verification. Power Harness The X-9 Gate Operator requires a single phase AC line to operate and charge the batteries. 1. Turn off the main switch or breaker for Auxiliary Power Connection. See page 29 for further details. the power line being used. 2. Move the selector switch on the Incoming

Summary of the content on the page No. 20

E ELECTRICAL INST LECTRICAL INSTALLA ALLATION – SINGLE UNIT TION – SINGLE UNIT Single Unit Connections Connect the wires from the motor unit to the terminal block mounted next to the control board. Match wire colors to the terminal block. Match Colors Connect the wire harness to the “OPEN RIGHT” connector if the gate opens towards the right side. Connect the wire harness to the “OPEN LEFT” connector if the gate opens towards the left side. Obstruction Obstruction Overlap Delay Overlap Delay


Alternative user manuals
# User manual Category Download
1 Viking Access Systems Vehicular Gate Opener UL 991 User manual Garage Door Opener 2
2 Viking Access Systems Vehicular Gate Opener UL 325 User manual Garage Door Opener 0
3 Sony Remote Commander RM-V111T User manual Garage Door Opener 50
4 Sony RM-B750 User manual Garage Door Opener 22
5 Sony RCP 920 User manual Garage Door Opener 5
6 Aspire Digital ASPIRE RF RFKGT User manual Garage Door Opener 0
7 Aiphone IS-SS-HID-I User manual Garage Door Opener 0
8 Allstar Products Group 6500 User manual Garage Door Opener 3
9 Allstar Products Group 8832 User manual Garage Door Opener 0
10 Allstar Products Group 9931 User manual Garage Door Opener 1
11 Allstar Products Group 8822 User manual Garage Door Opener 1
12 Allstar Products Group CHALLENGER AC9500 User manual Garage Door Opener 7
13 Allstar Products Group 9921 User manual Garage Door Opener 2
14 Allstar Products Group 6000 User manual Garage Door Opener 1
15 Allstar Products Group CHALLENGER AC9300 User manual Garage Door Opener 15