Summary of the content on the page No. 1
GARAGE DOOR OPENER MODELS
® TM ® TM
PowerMax 1200/1500, SC 1200/1500, TriloG 1200/1500, PowerLift 900, GPower 900,
® ®
SilentMax 1000/1200, CB 1000/1200, IntelliG 1000/1200
SCREW/BELT/CHAIN DRIVES
OPERATION & MAINTENANCE MANUAL
® ®
Includes INTELLICODE 2 Remote Control. Safe-T-Beam System must be installed to close door.
For use only with residential sectional or one piece overhead garage doors.
® ®
Homelink and Car2U compatible.
Need help or have questions? DO NOT RETURN to the store. Call
Summary of the content on the page No. 2
Table of Contents 1 Safety Information 2 3 4 TRANSMITTER COMPLIANCE STATEMENT Safety Notifications .......................................... 3 Transmitters comply with all United States and Canadian legal Important Safety Instructions ............................ 3 requirements as of the date of manufacture. No warranty is made that Infrared Protection Function ............................. 3 they comply with all legal requirements of any other jurisdiction. If transmitters are to
Summary of the content on the page No. 3
Safety Information 1 OVERVIEW OF POTENTIAL HAZARDS IMPORTANT SAFETY INSTRUCTIONS READ THIS SAFETY INFORMATION Potential Hazard Effect Prevention CONVENTIONS USED IN THESE INSTRUCTIONS Garage doors are large, heavy objects that move with the help of WARNING Keep people clear of opening springs under high tension and electric motors. Since moving objects, Could resul t while door is moving. springs under tension, and electric motors can cause injuries, your in Death
Summary of the content on the page No. 4
Features 2 Begin here ONLY AFTER completing assembly and installation of the opener. Review the Assembly and Installation poster to ensure all steps have been performed. Contact your Genie® Professional Dealer for an installation poster, if needed, or call 1-800-35GENIE. You may also visit www.geniecompany.com to download a PDF file. SAFETY FEATURES OPENER FEATURES ® ® Safe-T-Beam (STB) Non-Contact INTELLICODE 2 Access Security System Reversing System A new generation superior encrypt
Summary of the content on the page No. 5
Required Programming 3 NOTE: Before you begin programming, check to make sure there are There are 4 programs (The 2 “Factory Set” programs are unlikely to no objects in the garage door opening. need changes.) 1. Door Travel Limits Program INTRODUCTION – This program is used to set ho w far your door travels up and down. Now that your Genie garage door opener is installed, you will want to 2. Remote Programs (Default menu) program the opener so that the door opens and closes properly a
Summary of the content on the page No. 6
2 Required Programming 3 TRAVEL LIMITS WARNING 3 Release down arrow button (-) and the long LED will begin flashing. • Make sure doorway is in view and c lear of obstac les and people to avoid injury or damage to property. PROGRAM • DO NOT operate this unit from wall console before LIMITS are set. Severe damage to the opener can occur. • The shuttle MUST be engaged to carriage BEFORE setting limits. See Installation Poster (if provided) or call Customer Service at
Summary of the content on the page No. 7
Required Programming 3 8 5 Press and release the Program Set button (both Press and hold the up arrow button (+) until door LEDs flash blue and go off). is fully open, then release. Watch carriage as it approaches the power head to avoid contact with powerhead. PROGRAM PROGRAM PROGRAM SET – + SET – HOLD The DOWN (closed) limit is programmed. Opening Garage Door (Up Limits) NOTE: Beginning with garage door closed is recommended but not necessary. 6 Press and hold the up arrow button
Summary of the content on the page No. 8
Required Programming R quired Pr ramming 3 WALL CONSOLE / Overview Series III Wall Consoles with Black Buttons MODEL AC SR3 THE GENIE COMPANY This opener has a serial FCC ID: B8Q AC SR3 Residential Door Operator number sticker in which IC: 2 33A-CS 1D 120V. 60HZ. 5A Indicator Light S/N:10XXXX XXXXXXX the serial numbers begin Indicator light will display Red when wall console is properly wired and ™ ™ with 10 or higher. Sure-Lock is OFF. When Sure-Lock is ON, indicator light flash
Summary of the content on the page No. 9
Required Programming 3 Force and Speed Control 12 Lay a 2” x 4” board at under the center of the door opening. These controls are factory programmed and automatically set themselves when you use the Wall Console to open and close the garage door for the rst time. The door MUST complete a full cycle from open to close and close to open before it is fully set. NOTE: Force or Speed controls DO NOT require programming. Force and Speed Limits are factory set and rarely require adjust
Summary of the content on the page No. 10
Required Programming 3 REMOTES / New Intellicode 2 Openers NOTE: The following instructions are for the remote control 16 Remove protective film for battery from remote. transmitters (“Remotes”) provided with this opener. This Remote is preset for use with the Intellicode 2 Access Security System. Refer to page 14 for additional information on Intellicode 1 and 2 Remotes and how to switch from Intellicode 2 to Intellicode 1. See page 14 for programming instructions using Intellicode
Summary of the content on the page No. 11
Required Programming 3 The Remote button is now programmed. 18 Press and release the same button on the remote (both LED’s flash blue and then turn off). Repeat as necessary for additional Remotes. To program the same Remote for other garage door openers, repeat the steps above using one of the other two Remote buttons. Each Remote can be programmed for three door openers. BASIC PROGRAMMING IS COMPLETE AND YOUR GARAGE DOOR IS READY TO USE! NOTE: For Car2U and HomeLink, park the car o
Summary of the content on the page No. 12
Optional Programming 4 PROGAMMING THE WIRELESS KEYPAD Opener Setting Up a PIN 4. Press Up/Down key again. Opener LEDs will turn o. 5. Press Up/Down key again. Door opener will run. NOTE: Pressing any key will stop or start the opener while the door is in motion. The door will automatically stop fully open or closed. When the door has stopped moving, pressing on any single button will activate door until backlight goes off (30 seconds) NOTE: Rapid blinking of the red LED on the Powe
Summary of the content on the page No. 13
Optional Programming 4 CLEARING MEMORy f OR REMOTES 4 To verify that the memory is cleared, press a remote button that was previously programmed to the Powerhead. 1 Press the Program Set button on the Powerhead and hold 2 seconds, round LED comes ON. PROGRAM PROGRAM T – + SET HOLD HOLD 2 seconds 2 seconds 2 Release the Program Set button, round LED goes off and the long LED flashes purple. PROGRAM – + If the memory has been cleared, the Remote will not activate the door opener. NOTE
Summary of the content on the page No. 14
Optional Programming 4 ® INTELLICODE 1 REMOTES Remotes provided with this unit can operate other (Intellicode® 1) 6 Press the Remote button again. If the door moves, the models of Genie® garage door openers . The default Intellicode® 2 setting Remote button is programmed to your opener. must be changed to Intellicode® 1. (Follow these same steps to change Intellicode® 1 back to Intellicode® 2.) If you have questions, see your Genie® instructions for this Intellicode® 1 NOTE: The b
Summary of the content on the page No. 15
One-Piece Doors 5 ATTACHING DOOR BRACkET TO DOOR ATTACHING DOOR ARM TO DOOR BRACkET 1 1a Using bracket, mark holes on door or frame and drill Screw drive models: 5/32" hole completely through door frame. One-Piece Doors will only accept a straight door arm. Cur Curved door arm ved door arm 3/8"-16 x 7/8" Bolt Door centerline Door centerline 3/8 3/8" Lock nut " Lock nut Straight door arm (not inc Straight door arm (not included) luded) NOTE: Center bracket on door as high as possible, p
Summary of the content on the page No. 16
Maintenance and Adjustments 6 If you have any questions, please do not hesitate to contact customer A. Contact Reverse Test service at: 1-800-35-GENIE or visit www.geniecompany.com See page 9. IMPORTANT SAf ETy INSTRUCTIONS WARNING Use of any other wall control can cause unexpected operation of WARNING the door and loss of lighting feature. Locate wall console within TO REDUCE THE RISK OF SEVERE INj URY OR DEATH, READ sight of door and far enough from door to prevent contacting i
Summary of the content on the page No. 17
Maintenance and Adjustments 6 REGULAR MAINTENANCE (continued) Reset Open/Close Travel Limit Performing all eleven (11) Limits/Force setting steps (see pages 6-8) • Screw drive models: V erify shuttle release lever is in ENGAGED erases previous Limits/Force settings. (UP) position (pull release handle toward opener and let go) • Chain/belt drive models: V erify bullet is enga ged to carria ge. NOTE: The opener will not close the door automatically unless the ® P
Summary of the content on the page No. 18
Maintenance and Adjustments 6 ADj USTMENT GUIDES LED indicator colors: OFF Blue Purple Red Powerhead LEDs CAUTION Force Level LONG LED ROUND LED Door closing force is FACTORY set and requires no adjustment Force Level 1 Off BLUE for normal operation. Force Level 2 BLUE Off • NEVER adjust the force settings to compensate for damage, Force Level 3 BLUE BLUE including an unbalanced door, binding door track, or broken spring. Force Level 4 Off PURPLE • P erform mo
Summary of the content on the page No. 19
Maintenance and Adjustments 6 ADj USTMENT GUIDES (continued) LED indicator colors: OFF Blue Purple Red Powerhead LEDs Speed Settings (DC motors only) Speed Level LONG LED ROUND LED Speed settings are pre-programmed at the factory for the maximum speed. Speed settings should not need adjustment with this unit. High RED RED Medium PURPLE PURPLE However, travel speed for the opener can be adjusted to a slower speed in both the Open and Close directions, to minimize wear on Lo
Summary of the content on the page No. 20
Wiring Diagram 7 Opener circuit wiring diagram. This wiring diagram is for reference only. WARNING OPENING COVER MAY CAUSE ELECTRIC SHOCK. Disconnect power from opener prior to removing cover. POWER CORD CHAIN MOTOR SCREW DRIVE MOTOR CONNECTOR PRINTED CIRCUIT BOARD BLACK RED WHITE RED BLACK BLACK 1 2 3 4 GREEN STB BWC (IWC) 1 2 3 4 5 6 * CHOKE STRIPED WHITE STRIPED WHITE WHITE STRIPED WHITE ® SAFE-T-BEAM WHITE BLACK (Purchased Separately) INTELLIGENT WALL CONSOLE BLACK 7 6 5 4 3 2 1 WA