Summary of the content on the page No. 1
AUTOMATIC GATE OPERATOR
FOR VEHICULAR SLIDE GATES
INSTALLATION MANUAL FOR THE PROFESSIONAL INSTALLER
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safet
Summary of the content on the page No. 2
TABLE OF CONTENTS Gate Operator Class Categories --------------------------------------------------------inside cover Important Safety Instructions -----------------------------------------------------------page 1 Important Safety Instructions for the System Designer ----------------------------page 2 Important Safety Instructions for the Installer ---------------------------------------page 2 Secondary means of Protection Against Entrapment -------------------------------page 4 Import
Summary of the content on the page No. 3
IMPORTANT SAFETY INSTRUCTIONS FOR THE GTO/PRO SL-1000/2000 AND GTO/PRO SL-1000B/2000B AUTOMATIC SLIDE GATE OPERATORS Because automatic gate operators produce high levels of force, all system designers, installers, and consumers have an obligation to know the potential hazards associated with improperly designed, installed, or maintained gate operator systems. Keep in mind that the gate operator is just one component of the total gate operating system. Each component must work in unison to
Summary of the content on the page No. 4
IMPORTANT SAFETY INSTRUCTIONS FOR THE SYSTEM DESIGNER WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. This operator is intended for use only on vehicular gates. Pedestrians must be supplied with a separate walk-through gate (see Entrapment Protection on page 6). 3. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion. FOR THE INSTALLER
Summary of the content on the page No. 5
IMPORTANT SAFETY INSTRUCTIONS 5. Mount access controls away from the gate (minimum distance is 10 feet). The user must have full view of the gate but be unable to touch it while operating the controls. 6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate. III. After Installation 1. Review ALL safety instructions with the consumer/end user and explain the basic operation and safety systems of the entire gate operator system, includi
Summary of the content on the page No. 6
IMPORTANT SAFETY INSTRUCTIONS SECONDARY MEANS OF PROTECTION AGAINST ENTRAPMENT As specified by Underwriters Laboratories Inc. UL 325 (31.1.1), automatic gate operators shall have provisions for, or be supplied with, at least one independent primary and one independent secondary means to protect against entrapment. GTO gate operators utilize Type A, an inherent entrapment sensing system, as the primary type of entrapment protection. The GTO/PRO SL-1000/2000 and GTO/PRO SL-1000B/2000B gate ope
Summary of the content on the page No. 7
IMPORTANT SAFETY INSTRUCTIONS FOR THE CONSUMER/END USER WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS manual with all persons authorized to use your gate. SAVE THESE INSTRUCTIONS. 3. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Your automatic gate is not for pedestrian use. If pedestrian traf
Summary of the content on the page No. 8
IMPORTANT SAFETY INSTRUCTIONS REQUIRED SAFETY PRECAUTIONS FOR GATES INSTALL SCREEN GUARD OVER GATE AND FENCE Injuries may occur when people place their hands, arms, legs, etc., through openings in the gate grill when the gate is operated, trapping them between the grill and the fence post (or fence). All openings of a horizontal slide gate 1 must be guarded or screened to prevent a 2 /4” diameter sphere from passing through openings anywhere in the gate. This screen/guard must also be instal
Summary of the content on the page No. 9
L L I I S S IMPORTANT SAFETY INSTRUCTIONS These warning labels should be found at the locations specified below. If any of them are missing, immediately contact your installer for replacements. ! ! W A RNING WARNING • Fingers, hands, and • Moving parts inside are capable of loose clothing may be causing injury to fingers and hands. dragged into chain sprockets. • DO NOT remove operator housing. • Fingers and hands can • Consult your safety manual before be injured by rotating spro
Summary of the content on the page No. 10
IMPORTANT SAFETY INSTRUCTIONS Continued from page 7 These warning labels should be found at the locations specified below. If any of them are missing, immediately contact your installer for replacements. ! W ARNING • Fingers, hands, and loose clothing may be dragged into chain sprockets. • Fingers and hands can be injured by rotating sprockets. ! W ARNING • Keep hands, fingers, and loose clothing away from chain and sprockets. warning sign located (inside housing) over the top sprocket at
Summary of the content on the page No. 11
GTO PRO SL-1000 SERIES TECHNICAL SPECIFICATIONS DRIVE • Powered by a 12 V motor with integral case hardened steel gear reduction to 90 rpm. Generates 155 in. lb. of torque at 12 V. Motor temperature range -30 °F to +160 °F. • Gate velocity: 1 ft/s. POWER • The PRO SL-1000 system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable battery. • Battery charge for PRO SL-1000 is maintained by a 18 Vac (40 VA) transformer rectified to 14.5 Vdc through the GTO Control Board. Two (2) blade-s
Summary of the content on the page No. 12
GTO PRO SL-2000 SERIES TECHNICAL SPECIFICATIONS DRIVE • Powered by a 12 V motor with integral case hardened steel gear reduction to 90 rpm. Generates 310 in. lb. of torque at 12 V. Motor temperature range -30 °F to +160 °F. • Gate velocity: 1 ft/s. POWER • The PRO SL-2000 system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable battery. • Battery charge for PRO SL-2000 is maintained by a 18 Vac (40 VA) transformer rectified to 14.5 Vdc through the GTO Control Board. Two (2) blade-s
Summary of the content on the page No. 13
PARTS IDENTIFICATION Operator Control Box with Operator Housing Control Board (A207) and Battery Receiver (AQ202) 32’ Drive Chain (RB207) 18 Vac Transformer (2) Chain Brackets (204IH) GTO Transmitter 120 Volt (RB570) (RB740) (2) 2” square x 48” long legs (206IH) 1 1 (4) / ”-20 x / ” Screws 4 2 (RB226) 3 (4) /8” Lock Washers (RB641) 3 (4) /8”-16 x 2” diameter U-Bolts 3 and (8) / ” Serrated Nuts (RB210) 8 (2) Chain Master Links (RB208) 3 (4) /8” Nuts (RB668) 3 ” (4) /8” -16 x 3 Carriage Bolts
Summary of the content on the page No. 14
SINGLE GATE OPERATOR INSTALLATION GATE PREPARATION Be sure the gate is properly installed and slides smoothly before installing the GTO/PRO Slide Gate Operator. The gate must be plumb, level, and move freely. The gate must not bind or drag on the ground. Never use a wheel on the gate, because the additional drag and resistance can cause the operator to obstruct. Level Plumb Concrete Concrete OVERVIEW OF OPERATOR INSTALLATION The diagram below shows a single slide gate installation with recomm
Summary of the content on the page No. 15
W A R N IN G RECOMMENDED WIRING AND USE OF CONDUIT Run the low voltage wire and receiver wire through PVC conduit into the slider unit to protect it from lawn mowers, weed eaters, grazing animals, etc. PVC conduit should be used for accessory wires such as loop detectors, key pads, card readers or any other entry device. Roller Guard Roller Guard ® ® CAUTION AUTOMATIC GATE AUT CAUTION OMATIC GATE ST 1-800-543-GA AND CLEAR TE STAND CLEAR 1-800-543-GATE Operator Operator Roller Guard Roller Gu
Summary of the content on the page No. 16
DETERMINING THE MOUNTING POSITION AND MOUNTING THE OPERATOR STEP 2 Illustration B Install chain brackets at each end of the gate on the inside (operator side) of the gate (see Overview Illustration, page. 12). Position the tops of chain brackets no more than 6” above the String bottom corners of the gate frame and secure with U-bolts (see Quick Release Pin Illustration B). The chain brackets will work on gate frames Chain Bracket 3 1 1 /4” to 2 / ” in diameter or square tube gates. The
Summary of the content on the page No. 17
INSTALLING THE CHAIN STEP 5 Illustration F After the concrete has hardened, remove the string Chain Bracket from the quick release pins. Attach the chain to one quick release pin with a master link (see Illustration F). Run the chain through the chain sprockets (see Quick Release Pin Illustration G). STEP 6 Pull the chain to the second chain bracket leaving approximately four inches of slack (see Illustration G). Do not pull chain tight; a tight chain will Chain interfere with the oper
Summary of the content on the page No. 18
POWERING THE SYSTEM CONNECTING THE BATTERY Make sure the control box power switch is in the OFF position. STEP 8 Unscrew and remove the front cover of the control box and slide battery into position with its terminals to the left (see illustration). Make sure the battery OFF fits snugly in control box. Connect the black battery lead to the negative (–) terminal, RED WIRE to positive (+) and the red battery lead to the positive (+) terminal. DO NOT allow battery leads to touch the control
Summary of the content on the page No. 19
INSTALLATION OF THE GTO TRANSFORMER CONT. 2) If the gate is binding or dragging, or if ball bearing rollers are not used, it will require more than 10 amps to move it. This will reduce the MNC. 3) The charts are based on the transformer being plugged into an outlet that provides a line voltage of 120 volts; if the outlet provides less than 120 volts (for example, some rural areas may only provide 105 volts), it can reduce the MNC by as much as 50%. 4) A fully charged standard battery has
Summary of the content on the page No. 20
STEP 9 Run the low voltage wire from the electrical outlet to the control box. Do not exceed 1000’. NOTE: Pull approximately 1 foot of extra low voltage wire into the control box to accommodate terminal connections. To maintain adequate charging power, use appropriate gauge, stranded, direct burial wire (see Accessory Catalog). Do not use telephone wire or any solid core wire because it will not provide adequate current. Never splice wires together. INSTALLATION OF THE GTO TRANSFORMER CONT