Summary of the content on the page No. 1
FPD1000-HP SERIES
HIGH PRESSURE
Positive Displacement Flowmeters
Summary of the content on the page No. 2
Summary of the content on the page No. 3
V cc 12 3 To the owner: INSTALLATION Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few min- 1. Use thread sealant on all pipe threads. utes to read through the manual before in- 2. Ensure the meter is installed so that stalling and operating your meter. If you rotor shafts are always in a horizontal have any problems with the meter, refer to plane (See Figure 1). Flow is bi-direc- the Maintenance and Troubleshooting sec- tional. tions of the manual. This manual contains c
Summary of the content on the page No. 4
12 Reed Relay Specifications Reassembly: •Two wire SPST N/O. 1. Replace rotors into the meter body. The rotors should be at 90 degrees to each •Switching voltage 150 VDC; maximum other. current 0.25 Amps. 2. Lightly rotate the rotors by hand. They •Rating 3 watts. must rotate freely. •Duty cycle 20% ON, 80% OFF. 3. Install O-ring. 4. Replace the meter cap and tighten the Figure 3 eight screws uniformly to 35Nm (25 Ft. Lbs.). 5. Replace the pulser cap and tighten the four screws. Reed Switch Wiri
Summary of the content on the page No. 5
TROUBLESHOOTING Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter, clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer. 3. Damaged rotors Replace rotors. Strainer must be fitted in-line. 4. Meter connections over- Re-adjust connections. tightened REDUCED FLOW 1. Line strainer partially Clean strainer. THROUGH THE blocked METER 2. Fluid is too viscous Maximum viscosity 1000 centipoise
Summary of the content on the page No. 6
DISPLAY PARTS LISTING Model: FPD1202-HP 3 4 9 TERMINAL BLOCK 10 6 2 8 7 1 u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item Rec. Part or Set No. Qty. Parts (Order from this column only) Part Description 11 MS1NS Meter Body Assembly NPT 28 u MS367S Bolt Set - Socket Head 31 MS170H Pulser Cap (BSP) 31 MS170HN Pulser Cap (NPT) 44uMS115S Bolt Set - Socket Head 61 MS3HES Meter Cap & Hall Effect Assembly * 61 MS3HPS Meter Cap & Reed Switch
Summary of the content on the page No. 7
SPECIFICATIONS Pulse Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 2 to 100 / 0.53 to 26.4 Below 5 centipoise 5 to 100 / 1.32 to 26.4 Accuracy of Reading ± 1% Maximum Viscosity 1000 Centipoise Maximum Operating Pressure 55160 kPa / 8000 PSI / 551 Bar Maximum Operating Temperature 120°C / 248°F Pulse Type Hall Effect Sensor / Reed Switch Pulses per Litre/Gallons 1000 / 3785 Meter Dimensions 86mm Dia. / 3.4” Dia. (Meter Body) 83mm / 3.25” (Port Fac
Summary of the content on the page No. 8
DISPLAY PARTS LISTING Model: FPD1203-HP 3 4 9 TERMINAL BLOCK 10 6 2 8 7 1 u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item Rec. Part or Set No. Qty. Parts (Order from this column only) Part Description 11 MS2NS Meter Body Assembly NPT 28 u MS367S Bolt Set - Socket Head 31 MS170H Pulser Cap (BSP) 31 MS170HN Pulser Cap (NPT) 44uMS115S Bolt Set - Socket Head 61 MS3HES Meter Cap & Hall Effect Assembly * 61 MS3HPS Meter Cap & Reed Switch
Summary of the content on the page No. 9
SPECIFICATIONS Pulse Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 500 / 4.0 to 132 Below 5 centipoise 25 to 500 / 6.0 to 132 Accuracy of Reading ± 1% Maximum Viscosity 1000 Centipoise * Maximum Operating Pressure 55160 kPa / 8000 PSI / 551 Bar Maximum Operating Temperature 120°C / 248°F Pulse Type Hall Effect Sensor / Reed Switch Pulses per Litre/Gallons 400 / 1514 Meter Dimensions 86mm Dia. / 3.4” Dia. (Meter Body) 83mm / 3.25” (Port Face
Summary of the content on the page No. 10
Summary of the content on the page No. 11
Summary of the content on the page No. 12
M-4125 / 0405