Summary of the content on the page No. 1
The Chamberlain Group, Inc.
A DUCHOSSOIS ENTERPRISE
TM
845 Larch Avenue
Elmhurst, Illinois 60126-1196
Complies with UL 325
regulations effective
January 1, 1993
®
Garage Door Opener
Model 2000SDR
Model 1000SDR
1/2 HP
1/3 HP
For Residential Use Only
n Please read this manual and the enclosed safety materials carefully!
n Fasten the manual near the garage door after installation.
®
n The door WILL NOT CLOSE unless the Protector System is connected and properly
aligned.
n Periodic checks of the op
Summary of the content on the page No. 2
Contents Safety alert symbol review............................................2 Install the lights and lens ..........................................19 Safety information and precautions ..............................3 Attach the manual release rope and handle...............19 Testing your garage door for binding & balance ..........3 Fasten the door bracket (sectional door)...................20 Hardware supplied ........................................................3 Fasten the door b
Summary of the content on the page No. 3
Safety Information and Precautions CAUTION CAUTION WARNING An unbalanced garage door might not reverse when To avoid damage to the garage door and opener, disable required and someone under the door could be seriously locks before installing and operating the opener. Use a injured or killed. wood screw or nail to hold locks in the "open" (unlocked) position. If your garage door binds, sticks or is out of balance, call for professional garage door service. Garage doors, door Operation at other th
Summary of the content on the page No. 4
Carton Inventory Your garage door opener is packaged in two cartons which contain the power unit and parts illustrated below. Accessories will depend on model purchased. If anything is missing, carefully check the packing material. Parts may be "stuck" in the foam. KEEP THE FOAM INTACT (see page 6). Hardware is listed on page 3. Model 2000SDR Model 1000SDR Model 2000SDR Model 1000SDR SECURITY✚ SECURITY✚ 3-Channel Remote Control Single-Function Remote Control Multi-Function Lighted Door Control
Summary of the content on the page No. 5
— — — — — — — — Before you begin, survey your garage area to see whether any of the conditions below apply to your installation. SECTIONAL Door or ONE-PIECE Door with Track Installation FINISHED CEILING Support bracket & fastening hardware is required. Horizontal and vertical reinforcement See page 13. is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 20 for details. Header Wall Extension Spring OR OR One-Piece Door-Ext
Summary of the content on the page No. 6
Assembly Section: Pages 6 - 7 ASSEMBLY STEP 1 Fasten the Rail To the Power Unit The Chamberlain Group, Inc.
Screw Drive LM 114A1794
NOTE: To aid in assembly and installation, replace Attaching Rail Assembly & Coupling to Chassis
the foam packing around the power unit. Remove it 6/9/94 - 6/18/94 - 10/19/9
after Installation Step 5. 12/7/94 • Working on a level surface, align the rail assembly with the power unit, as shown. Power Unit
Rail/Power Unit
• Slip the coupling over the rail s
Summary of the content on the page No. 7
ASSEMBLY STEP 3 Attach the Rail Brackets 1/4"-20 Rail Lock Nuts • Align rail brackets to end of rail assembly, as shown. Brackets • Insert two 1/4"-20 x 5/8" hex screws and lock nuts. Tighten securely with a 7/16" socket. Hardware Shown Actual Size 1/4" - 20 1/4"-20x5/8 Rail 1/4" - 20 x 5/8" Lock Nut Hex Hex Screw Screws You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section: IMPORTANT INSTALLATION INSTRUCTIO
Summary of the content on the page No. 8
Installation Section: Pages 8 – 23 SECTIONAL DOOR AND
The Chamberlain Group, Inc. Installation Step 1 WARN ONE-PIECE DOOR WITH TRACK ING WARNING Position Header Bracket SECTIONAL DOOR AND
Determine Header Bracket Location Sectional and One-Piece Track Installations If the header bracket is not rigidly fastened to a Installation procedures vary according to garage ONE-PIECE DOOR WITH TRACK structural support on the header wall or ceiling, the door types. Follow the instructions which ap
Summary of the content on the page No. 9
ONE-PIECE Door Without Track Read the Safety Instructions on page 8. They also apply to doors without tracks. Unfinished • Close the door and mark the inside Header Wall Ceiling Vertical vertical centerline of your garage Centerline 2x4 door. Extend the line onto the header wall above door. Structural Supports If headroom clearance is minimal, you can install the header bracket on the ceiling. See page 10. • If you need to install the header 2x4 bracket on a 2x4 (on wall or Vertical Header Suppo
Summary of the content on the page No. 10
You can attach the header bracket either to the wall Installation Step 2 above the garage door, or to the ceiling. Follow the instructions which will work best for your particular Install the Header Bracket requirements. Fastening the Header Bracket to the Ceiling Fastening the Header Bracket to the Wall • Center the bracket on the vertical guideline with the • Extend the vertical guideline onto the ceiling as shown. bottom edge of the bracket on the horizontal line as • Center the bracket
Summary of the content on the page No. 11
Installation Step 3 Attach the Rail to the Header Bracket • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring. • Position the rail bracket against the header bracket. • Align the bracket holes and join with a clevis pin as shown. • Insert a ring fastener to secure. Header Wall Header Br
Summary of the content on the page No. 12
® The Protector System IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR WARNING The safety reversing sensor must be connected and Without a properly working safety reversing sensor, aligned correctly before the garage door opener will persons (particularly children) could be injured or killed move in the down direction. This is a required safety by a closing garage door. Read and follow all device and cannot be disabled. instructions. To protect small children, install the safety reversi
Summary of the content on the page No. 13
Installation Step 4 Install the Safety Reversing Sensor (Receiving and Sending Eyes) Installing the Brackets DOOR TRACK MOUNT (Right Side) Figure 1 Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other Door across the garage door, with the beam from 4 – 6" above Track the floor. Lip They may be installed in one of three ways, as follows. Indicator light Garage door track installation (preferred): • Slip the curved arms over the rounded
Summary of the content on the page No. 14
Installation Step 4 (Continued) Install the Safety Reversing Sensor Mounting and Wiring the Safety Sensors Figure 4 • Slide a 1/4"-20x1/2" carriage bolt head into the slot on both sensors. Use wing nuts to fasten sensors to Wing nut brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension. See Figure 4. 1/4"-20x1/2" • Finger tighten the wing nuts. Carriage bolt Lens Recommended Wire Routing 1. Using insulated staples, run the wir
Summary of the content on the page No. 15
NOTICE WARNING WARNING The Chamberlain Group, Inc. The Chamberlain Group, Inc. Step 3 Position Opener Chassis The Chamberlain Group, Inc. Manual Disconnect 114A1794 Lift-Master One Piece Rail Step 3 Position Opener Chassis Liftmaster Screw Drive #114A1794 5/9/94 - 6/1/94, 6/8/94 - 10/20/94 114A1794 Lift-Master One Piece Rail 6/2/94, 6/15 5/9/94 - 6/1/94, 6/8/94 - 10/20/94 Installation Step 5 CAUTION Position the Opener Follow instructions which apply to your door To preve
Summary of the content on the page No. 16
Installation Step 6 WARNING Hang the Opener The opener could fall and injure someone if it is not properly secured. Fasten the opener securely to structural supports of the garage. Two representative installations are shown. Yours may be different. Hanging brackets should be angled, Figure 1, to provide rigid support. On finished ceilings, Figure 2, attach a sturdy metal bracket to structural Figure 1 supports before installing the opener. The bracket and fastening hardware are not supplied. Str
Summary of the content on the page No. 17
1 1 LIGHT LIGHT Installation Step 7 WARNING WARNING Install the Door Control and Connect all Wiring DO NOT CONNECT TO LIVE ELECTRICAL WIRING. CONNECT ONLY TO 24 VOLT LOW VOLTAGE WIRES. CONNECTION TO LIVE WIRES OR HIGHER VOLTAGE MAY CAUSE SERIOUS Locate the door control within sight of the door at a minimum INJURY FROM SHOCK, BURN OR ELECTROCUTION. height of 5 feet where small children cannot reach, and away Children operating or playing with a garage door opener can from all moving parts of the
Summary of the content on the page No. 18
Installation Step 8 WARNING Electrical Requirements To prevent electrocution or fire, installation and wiring must be in compliance with local electrical and building To reduce the risk of electric shock, your garage door codes. opener has a grounding type plug with a third grounding Do NOT use an extension cord, 2-wire adapter, or change pin. This plug will only fit into a grounding type outlet. the plug in any way to make it fit your outlet. If the plug doesn't fit into the outlet you have, co
Summary of the content on the page No. 19
CONTROL CENTER NOTICE Installation Step 10 Install the Lights and Lens 100 Watt Max. Light Bulb • Install a 100 watt maximum light bulb in each socket. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Top Lens Slot Then the lights will turn OFF. • Insert bottom lens tabs into slots on chassis and tilt Top Lens Tab towards chassis to engage top tabs, then drop down gently into place. (See illustration.) • To remove, lift lens up and gently tilt sl
Summary of the content on the page No. 20
Installation Step 12 CAUTION CAUTION Fasten Door Bracket Follow instructions which apply to your door type To prevent damage to steel, aluminum, fiberglass or as illustrated below or on page 21. glass panel doors, always reinforce the inside of the door both vertically and horizontally with an angle iron. A horizontal brace should be long enough to be secured to 2 vertical supports. A vertical brace should cover the height of the top panel. The illustration shows one piece of angle iron as the