Summary of the content on the page No. 1
07/06/01 12:36:58 32Z4D602_001
INTRODUCTION
Thank you for purchasing a Honda engine. We want to help you to
get the best results from your new engine and to operate it safely.
This manual contains information on how to do that; please read it
OWNER’S MANUAL
carefully before operating the engine. If a problem should arise, or
if you have any questions about your engine, consult an
MANUEL DE L’UTILISATEUR
authorized Honda servicing dealer.
MANUAL DEL PROPIETARIO
All information in this publication
Summary of the content on the page No. 2
07/06/01 12:37:09 32Z4D602_002 SAFETY INFORMATION COMPONENT & CONTROL LOCATION RECOIL STARTER STARTER GRIP Understand the operation of all controls and learn how to stop the engine quickly in case of emergency. Make sure the operator receives adequate instruction before operating the equipment. OIL FILLER CAP/ Do not allow children to operate the engine. Keep children and DIPSTICK pets away from the area of operation. Your engine’s exhaust contains poisonous carbon monoxide. Do not run the engin
Summary of the content on the page No. 3
07/06/01 12:37:33 32Z4D602_003 FEATURES BEFORE OPERATION CHECKS Centrifugal Clutch (applicable types) IS YOUR ENGINE READY TO GO? The centrifugal clutch automatically engages and transmits power For your safety, and to maximize the service life of your when engine speed is increased above approximately 2,900 rpm. equipment, it is very important to take a few moments before you At idle speed, the clutch is disengaged. operate the engine to check its condition. Be sure to take care of any problem
Summary of the content on the page No. 4
07/06/01 12:37:53 32Z4D602_004 OPERATION 3. To start a cold engine, move the choke lever to the CLOSED position. SAFE OPERATING PRECAUTIONS To restart a warm engine, leave the choke lever in the OPEN Before operating the engine for the first time, please review the position. CHOKE LEVER SAFETY INFORMATION section on page 2 and the BEFORE OPERATION CHECKS on page 3 . Carbon monoxide gas is toxic. Breathing it can cause unconsciousness and even kill you. O OP PE EN N CLOSED C CL LO OS SE ED D Avoi
Summary of the content on the page No. 5
07/06/01 12:38:05 32Z4D602_005 SETTING ENGINE SPEED STOPPING THE ENGINE Position the throttle lever for the desired engine speed. To stop the engine in an emergency, simply turn the engine switch on the equipment to the OFF position. Under normal conditions, The throttle lever shown here will be connected to a remote use the following procedure. control on the equipment powered by this engine. Refer to the instructions provided with that equipment for remote control 1. Move the throttle lever to
Summary of the content on the page No. 6
07/06/01 12:38:33 32Z4D602_006 SERVICING YOUR ENGINE SAFETY PRECAUTIONS Make sure the engine is off before you begin any maintenance THE IMPORTANCE OF MAINTENANCE or repairs. This will eliminate several potential hazards: Good maintenance is essential for safe, economical and trouble- Carbon monoxide poisoning from engine exhaust. free operation. It will also help reduce pollution. Operate outside away from open windows or doors. Burns from hot parts. Let the engine and exhaust system cool bef
Summary of the content on the page No. 7
07/06/01 12:38:55 32Z4D602_007 REFUELING 3. Refuel carefully to avoid spilling fuel. Do not fill the fuel tank completely. It may be necessary to lower the fuel level Recommended Fuel depending on operating conditions. After refueling, tighten the Unleaded gasoline fuel filler cap securely. U.S. Pump octane rating 86 or higher Except U.S. Research octane rating 91 or higher Keep gasoline away from appliance pilot lights, barbecues, Pump octane rating 86 or higher electric appliances, power tools
Summary of the content on the page No. 8
07/06/01 12:39:14 32Z4D602_008 Oil Level Check 3. With the engine in a level position, fill to the upper limit mark on the dipstick with the recommended oil (see page 7 ). Check the engine oil level with the engine stopped and in a level OIL FILLER CAP/DIPSTICK position. 1. Remove the oil filler cap/dipstick and wipe it clean. 2. Insert the oil filler cap/dipstick into the oil filler neck as shown, but do not screw it in, then remove it to check the oil level. UPPER LIMIT 3. If the oil level is
Summary of the content on the page No. 9
07/06/01 12:39:42 32Z4D602_009 AIR CLEANER SPARK PLUG A dirty air cleaner will restrict air flow to the carburetor, reducing Recommended Spark Plugs: CR5HSB (NGK) , engine performance. If you operate the engine in very dusty areas, U16FSR-UB (DENSO) clean the air filter more often than specified in the MAINTENANCE SCHEDULE. The recommended spark plug has the correct heat range for normal engine operating temperatures. Operating the engine without an air filter, or with a damaged air filter, will
Summary of the content on the page No. 10
07/06/01 12:40:07 32Z4D602_010 SPARK ARRESTER (optional equipment) HELPFUL TIPS & SUGGESTIONS Your engine is not factory-equipped with a spark arrester. In some STORING YOUR ENGINE areas, it is illegal to operate an engine without a spark arrester. Check local laws and regulations. A spark arrester is available Storage Preparation from authorized Honda servicing dealers. Proper storage preparation is essential for keeping your engine trouble-free and looking good. The following steps will help t
Summary of the content on the page No. 11
06/11/28 13:57:23 32Z4D602_011 Draining the Fuel Tank and Carburetor Storage Precautions If your engine will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any Gasoline is highly flammable and explosive, and you appliance that operates with a flame, such as a furnace, water can be burned or seriously injured when handling heater, or clothes dryer. Also avoid any area with a
Summary of the content on the page No. 12
06/11/28 13:57:45 32Z4D602_012 TAKING CARE OF UNEXPECTED PROBLEMS TECHNICAL INFORMATION ENGINE WILL Possible Cause Correction Serial Number Location NOT START Record the engine serial number, type and purchase date in the 1. Check control Vent knob Open vent knob. space below. You will need this information when ordering parts positions. CLOSE and when making technical or warranty inquiries. Fuel valve OFF. Move lever to ON position. Choke open. Move lever to CLOSED position unless the engine is
Summary of the content on the page No. 13
07/06/01 12:40:26 32Z4D602_013 Carburetor Modifications for High Altitude Operation Emission Control System Information At high altitude, the standard carburetor air-fuel mixture will be Source of Emissions too rich. Performance will decrease, and fuel consumption will The combustion process produces carbon monoxide, oxides of increase. A very rich mixture will also foul the spark plug and nitrogen, and hydrocarbons. Control of hydrocarbons and oxides cause hard starting. Operation at an altitud
Summary of the content on the page No. 14
07/06/01 12:40:56 32Z4D602_014 Replacement Parts Specifications The emission control systems on your Honda engine were designed, built, and certified to conform with EPA, California and GXV50 (PTO shaft S type) Canadian emission regulations. We recommend the use of Length Width 249 286 225 mm genuine Honda parts whenever you have maintenance done. Height (9.8 11.3 8.9 in) These original-design replacement parts are manufactured to the Dry mass [weight] 5.2 kg (11.5 lbs) same standards as the ori
Summary of the content on the page No. 15
06/11/28 13:58:41 32Z4D602_015 Quick Reference Information Fuel Unleaded gasoline (Refer to page 7) U.S. Pump octane rating 86 or higher Except Research octane rating 91 or higher U.S. Pump octane rating 86 or higher Engine oil SAE 10W-30, API SJ or later, for general use. Refer to page 7. Spark plug CR5HSB (NGK) U16FSR-UB (DENSO) Maintenance Before each use: Check engine oil level. Refer to page 8. Check air filter. Refer to page 9. First 10 hours: Change engine oil. Refer to page 8. Subsequent
Summary of the content on the page No. 16
06/11/28 13:59:19 32Z4D602_016 CONSUMER INFORMATION Canada: Honda Canada, Inc. Distributor/Dealer Locator Information 715 Milner Avenue Toronto, ON United States, Puerto Rico, and U.S. Virgin Islands: M1B 2K8 Visit our website: www.honda-engines.com Telephone: (888) 9HONDA9 Toll free (888) 946-6329 Canada: English: (416) 299-3400 Local Toronto dialing area Call (888) 9HONDA9 French: (416) 287-4776 Local Toronto dialing area or visit our website: www.honda.ca Facsimile: (877) 939-0909 Toll free (
Summary of the content on the page No. 17
07/06/01 12:42:44 33Z4D602_001 INTRODUCTION Nous vous remercions d’avoir porté votre choix sur un moteur Honda. Nous désirons vous aider à faire le meilleur usage de votre nouveau moteur et à l’utiliser en sécurité. Vous trouverez dans ce manuel des informations sur la manière d’y parvenir; veuillez le lire attentivement avant d’utiliser le moteur. En cas de problème ou pour toute question sur MANUEL DE L’UTILISATEUR le moteur, consultez un concessionnaire Honda agréé. Toutes les informations de
Summary of the content on the page No. 18
07/06/01 12:42:57 33Z4D602_002 INFORMATIONS DE SECURITE EMPLACEMENT DES PIECES ET COMMANDES DEMARREUR A LANCEUR POIGNEE DE DEMARREUR Comprenez bien le fonctionnement de toutes les commandes et apprenez comment arrêter le moteur rapidement en cas d’urgence. Veillez à ce que l’opérateur reçoive des instructions adéquates avant JAUGE/BOUCHON DE l’utilisation de l’équipement. REMPLISSAGE D’HUILE Ne pas autoriser des enfants à utiliser le moteur. Eloigner les enfants et les animaux de la zone d’utili
Summary of the content on the page No. 19
07/06/01 12:43:19 33Z4D602_003 PARTICULARITES CONTROLES AVANT L’UTILISATION Embrayage centrifuge (selon type) LE MOTEUR EST-IL PRET A FONCTIONNER? L’embrayage centrifuge s’engage automatiquement et transmet la Pour la sécurité et la longévité de l’équipement, il est important de puissance lorsque le régime moteur dépasse 2.900 min (tr/mn) environ. consacrer quelques instants à vérifier l’état du moteur avant l’utilisation. L’embrayage se désengage au régime de ralenti. Corriger tout problème con
Summary of the content on the page No. 20
07/06/01 12:43:37 33Z4D602_004 UTILISATION 3. Pour mettre en marche un moteur froid, placer le levier de starter sur la position FERME. CONSIGNES DE SECURITE D’UTILISATION Pour remettre en marche un moteur chaud, laisser le levier de starter sur Avant d’utiliser le moteur pour la première fois, lire la section la position OUVERT. INFORMATIONS DE SECURITEàlapage 2 etlasection CONTROLES LEVIER DE STARTER AVANT L’UTILISATIONàlapage 3. Le monoxyde de carbone est un gaz toxique. Il risque de provoque