Teledyne 450H user manual

User manual for the device Teledyne 450H

Device: Teledyne 450H
Category: Frozen Dessert Maker
Manufacturer: Teledyne
Size: 0.84 MB
Added : 9/26/2014
Number of pages: 49
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 450H. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 450H.

For your convenience

If looking through the Teledyne 450H user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 450H on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 450H to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 450H User manual - Online PDF
Advertisement
« Page 1 of 49 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 450H but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 450H. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1









INSTRUCTION MANUAL


MODEL 450H
OZONE MONITOR





© Teledyne Instruments
Advanced Pollution Instrumentation Division
(T-API)
9480 Carroll Park Drive
San Diego, CA 92121-5201

TOLL-FREE: 800-324-5190
TEL: 858-657-9800
FAX: 858-657-9816
EMAIL: api-sales@teledyne.com
WEB SITE: www.teledyne-api.com







02826
Rev. B1
5/15/06
Printed: 05/15/06

Summary of the content on the page No. 2

SAFETY MESSAGES Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described below: General Warning/Caution: Refer to the instructions f

Summary of the content on the page No. 3

TABLE OF CONTENTS SAFETY MESSAGES....................................................................................................................................II TABLE OF CONTENTS ...............................................................................................................................III FIGURES ........................................................................................................................................................V TABLES...........

Summary of the content on the page No. 4

5.3 A/D - D/A CALIBRATION PROCEDURE… ............................................................................................42 5.4 CURRENT LOOP CALIBRATION............................................................................................................43 6.0 MODEL 450H SPARE PARTS…………………………………………………………………………. APPENDIX A - ELECTRICAL SCHEMATIC INDEX ...........................................................49 P/N 02826B1 Teledyne API Model 450H O Monitor Instruction Manual -

Summary of the content on the page No. 5

FIGURES FIGURE 1.1 – NEMA 4X MOUNTING HOLE DIMENSIONS ............................................................16 FIGURE 1.2 – NEMA 4X ELECTRICAL POWER CONNECTIONS .................................................17 FIGURE 1.3 – NEMA 4X PNEUMATIC CONNECTIONS...................................................................18 FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS..............................................................19 FIGURE 1.5 - CONNECTING DIGITAL OUTPUTS .............

Summary of the content on the page No. 6

TABLES TABLE 1.1 DIGITAL OUTPUTS..............................................................................................................20 TABLE 1.2 CONTROL INPUTS ...............................................................................................................21 TABLE 1.3 FINAL TEST AND CALIBRATION VALUES ...................................................................25 TABLE 2.1 SYSTEM MODES..........................................................................

Summary of the content on the page No. 7

1.0 INTRODUCTION 1.1 Preface Teledyne API is pleased that you have purchased the Model 450H. We offer a full one- year warranty (see Section 1.2) and we at Teledyne API will be pleased to provide you with any support required so that you may utilize our equipment to the fullest extent. The Model 450H is a microprocessor based high concentration ozone monitor for monitoring process streams in water treatment, food processing, and research applications. The Model 450H has been designed

Summary of the content on the page No. 8

1.2 WARRANTY POLICY ADVANCED POLLUTION INSTRUMENTATION DIVISION 02024c Prior to shipment, Teledyne API equipment is thoroughly inspected and tested. Should equipment failure occur, Teledyne API assures its customers that prompt service and support will be available. COVERAGE After the warranty period and throughout the equipment lifetime, Teledyne API stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry. All m

Summary of the content on the page No. 9

All units or components returned to Teledyne API should be properly packed for handling and returned freight prepaid to the nearest designated Service Center. After the repair, the equipment will be returned, freight prepaid. 1.3 Principle of Operation The detection of ozone molecules is based on absorption of 254 nm UV light due to an internal electronic resonance of the O molecule. The Model 450H uses a mercury lamp 3 constructed so that a large majority of the light emitted is at the

Summary of the content on the page No. 10

P/N 02826B1 Teledyne API Model 450H O Monitor Instruction Manual - Page 10 3

Summary of the content on the page No. 11

1.4 Specifications Measurement Principle UV Absorption (Beer Lambert Law) Ranges 0-5%, 0-10%, 0-15% w/w 3 3 3 0-100 g/m , 0-200 g/m , 0-300 g/m 3 3 Measurement Units wt%, g/m , g/Nm (Operator selectable) Precision/Repeatability ±0.5% of full scale range Resolution 0.1 % w/w Linearity 1% Response Time (95%) <5 sec to 95% Compensation Pressure, temperature, gas molecular weight Gas Flow Rate 0.5 - 2 LPM o Temperature Range 5-45 C Alarm Relay Mode Latching or Non-Latching (Operator s

Summary of the content on the page No. 12

1. Instruction manual. 2. Power Cord CAUTION To avoid personal injury, always use two persons to lift and carry the Model 450H. Upon receiving the Model 450H please do the following: 1. Verify no apparent shipping damage. (If damage has occurred please advise shipper first, then Teledyne API.) 2. Before connecting power to the instrument, check the serial number tag to verify that the instrument has been configured for the correct line voltage and frequency connections

Summary of the content on the page No. 13

5. If the M450H has been configured with the auto-zero valve option, connect the oxygen or other zero gas source to the ¼” tube fitting labeled ‘Zero Gas Inlet.’ Do not exceed 30 psig in the zero air delivery line. NOTE The zero gas used must be clean and free of particles. If the gas contains particulate contamination, install a particulate filter in the zero air line. You can purchase an appropriate filter from Teledyne API. 6. With the ozone delivery line pressurized, adjust the

Summary of the content on the page No. 14

1.6 Installation (NEMA 4X Wall Mount Enclosure) The Model 450H NEMA 4X is shipped with the following standard equipment: 1. Instruction manual. CAUTION To avoid personal injury, always use two persons to lift and carry the Model 450H. Upon receiving the Model 450H please do the following: 2. Verify no apparent shipping damage. (If damage has occurred please advise shipper first, then Teledyne API.) 3. Mount the 450H to a vertical surface using four 5/16” bolts. See Figu

Summary of the content on the page No. 15

CAUTION Exhaust gas from the M450H may contain dangerous levels of ozone! 7. Connect the ozone delivery line to the ¼” inlet fitting on the bottom of the filter assembly. This assembly is located on the bottom face of the enclosure (See Figure 1.3.) The ozone delivery pressure should be regulated to no more than 30psig. All tubing used should be made of ozone resistant material such as PTFE(Teflon ™) or PFA. If new, unconditioned tubing is used for the ozone delivery line, the oz

Summary of the content on the page No. 16

FIGURE 1.1 – NEMA 4X MOUNTING HOLE DIMENSIONS P/N 02826B1 Teledyne API Model 450H O Monitor Instruction Manual - Page 16 3

Summary of the content on the page No. 17

FIGURE 1.2 – NEMA 4X ELECTRICAL POWER CONNECTIONS P/N 02826B1 Teledyne API Model 450H O Monitor Instruction Manual - Page 17 3

Summary of the content on the page No. 18

FIGURE 1.3 – NEMA 4X PNEUMATIC CONNECTIONS P/N 02826B1 Teledyne API Model 450H O Monitor Instruction Manual - Page 18 3

Summary of the content on the page No. 19

FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS 1.6 Electrical I/O Connections 1.6.1 Analog Output The analog output is a two pin connector (See Figure 1.4). The analog output can be configured for voltage or current output. The standard is a 0-5 volt output. 0-100mV, 0- 1V, 0-10V, and 4-20 mA outputs are also available. See Section 5.2 for information on setting other output ranges. 1.6.2 Relay Outputs Three form C relay outputs are provided on three pin connectors (See Figure

Summary of the content on the page No. 20

Output Description Normal Operating State 1 Power OK ON 2 Diagnostics Mode(Instrument not OFF monitoring) 3 Temperature Fault OFF 4 Pressure Fault OFF 5 UV Lamp Fault OFF 6 Flow Fault OFF 7 Performing Auto-Zero Calibration OFF 8-11 Not Used N/A 12 System OK(no faults) ON TABLE 1.1 DIGITAL OUTPUTS Each digital output is configured as a Collector/Emitter pair. The labels are ‘C’ and ‘E’ for these contacts, respectively. Figure 1.2 below shows the most common way of connecting the


Alternative user manuals
# User manual Category Download
1 Sony BRAVIA KDL-40SL130 User manual Frozen Dessert Maker 3
2 Sony BRAVIA KDL-32SL130 User manual Frozen Dessert Maker 4
3 Sony BRAVIA KDL-46S3000 User manual Frozen Dessert Maker 16
4 Sony RM-AX4000A User manual Frozen Dessert Maker 0
5 Sony BRAVIA KDL-40S3000 User manual Frozen Dessert Maker 18
6 Sony RM-AX4000 User manual Frozen Dessert Maker 9
7 Sony BRAVIA KDL-32S3000 User manual Frozen Dessert Maker 2
8 ADIC 2.6 User manual Frozen Dessert Maker 0
9 ADIC 4.3 User manual Frozen Dessert Maker 0
10 ADIC 601354 User manual Frozen Dessert Maker 0
11 ADIC SNMS 2.3 User manual Frozen Dessert Maker 0
12 Black & Decker ARCTIC TWISTER IC200 User manual Frozen Dessert Maker 171
13 Aroma AIC-234 User manual Frozen Dessert Maker 1
14 Aroma AIC-244 User manual Frozen Dessert Maker 0
15 Bosch Appliances MUM8 User manual Frozen Dessert Maker 1