Emerson FTA1100 user manual

User manual for the device Emerson FTA1100

Device: Emerson FTA1100
Category: Automobile Parts
Manufacturer: Emerson
Size: 0.32 MB
Added : 2/26/2013
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson FTA1100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson FTA1100.

For your convenience

If looking through the Emerson FTA1100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson FTA1100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson FTA1100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson FTA1100 User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson FTA1100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson FTA1100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 17

AT 1 Use arrows to choose the time of day that the Weekly Test is performed. Press to confi rm. FOR 1 Use arrows to choose the duration (engine run time) of the Weekly Test. Press to confi rm. NOW IN WEEK 1 Use arrows to choose current time frame in reference to the Weekly Test schedule. Press to confi rm. (Example: If test is programmed for every 2 weeks on Sunday and today were Friday then - If testing

Summary of the content on the page No. 18

SETTINGS HIGH RESERVOIR FEATURE SETTINGS AUDIBLE 1 Use arrows to enable or disable the audible alarm for High Reservoir Level. Press to confi rm. COMMON ALARM 1 Use arrows to enable or disable the common alarm output (ALR relay) for High Reservoir Level. Press to confi rm. PUMP ROOM 1 Use arrows to select the alarm output relay for High Reservoir Level (Disabled, PTR (Pump Room Trouble), ETR (Engine Trouble), Both PTR and ET

Summary of the content on the page No. 19

REMOVE DRIVE 1 Use arrows to enable or disable the Remove Drive feature. Press to confi rm. Much like a computer, the Remove Drive feature ensures fi le closure prior to removing the USB fl ash drive from the Mark IIXG. Use of this feature helps prevent fi le corruption. NOTE: The Mark IIXG also features an automatic daily save function. Every day at midnight (0:00) the events for that day are written to a fi le on the USB fl ash drive. This fi le is also a text fi le (

Summary of the content on the page No. 20

FACTORY DIAGNOSTICS RAW INPUT: ANALOG Input values are shown. This information is for factory level troubleshooting purposes. RAW INPUT: DISCRETE Input values are shown. This information is for factory level troubleshooting purposes. RAW INPUT: KEYS Input values are shown. This information is for factory level troubleshooting purposes. RAW OUTPUT: DISCRETE Output values are shown. This information is for factory level troubleshooting purposes. MARK IIXG STARTS Displays the total number of ti

Summary of the content on the page No. 1

F FT TA A1100 1100
Inst Installation and Ope allation and Oper ration Instru ation Instruc ct tions ions
Mark II Mark IIX XG G Dies Diese el l Engine Fire Pump C Engine Fire Pump Co on ntrolle troller rs s
NS1100-50
ECN 225126

Summary of the content on the page No. 2

Table of Contents INTRODUCTION ...........................................................................................................................1 MOUNTING CONTROLLER ............................................................................................................1 Wall Mount ................................................................................................................... 1 - 2 Floor/Base Plate Mount ........................................................

Summary of the content on the page No. 3

Pressure (continued) Overpressure Alarm .................................................................................................10 Recording - Delta .....................................................................................................10 Sensor ......................................................................................................................10 Calibration .....................................................

Summary of the content on the page No. 4

MAIN MENU - FACTORY (continued) Confi guration - Model Pressure Sensor ........................................................................................................15 Autostart NC ............................................................................................................15 User Input Number ...................................................................................................15 Low Suction ......................

Summary of the content on the page No. 5

WARNING RISK OF ELECTRICAL SHOCK Personal injury could occur. Ensure all power is disconnected before installing or servicing this equipment. These instructions are intended to assist in the understanding of the installation and operation of the FTA1100. Read through these instructions thoroughly prior to connecting the controller. If there are any questions unanswered in these instructions, please contact the local Firetrol representative or factory service department. INTRODUCTION ® Firetr

Summary of the content on the page No. 6

5. Using either the dimension print or by measuring the distance between the center lines of the 2 lower bracket slots, transcribe this dimension onto the wall. Note: The bottom edge of the en- closure should be a minimum of 12” (305 mm.) from the fl oor in case fl ooding of the pump room occurs. 6. Drill and put 2 anchors into the wall for the 2 lower bracket slot mounts. 7. Mark on the wall, the location of the holes in the upper mounting ears. 8. Drill and put 2 anchors into wall for the upp

Summary of the content on the page No. 7

2. Verify that the controller information is what is required on the project: • Firetrol catalog number • Engine voltage and polarity of grounding • Incoming line voltage and frequency • Maximum system pressure 3. Project electrical contractor must supply all necessary wiring for fi eld connections in accordance with the National Electrical Code, local electrical code and any other authority having jurisdic- tion. 4. Refer to the appropriate fi eld connection drawing for wiring informatio

Summary of the content on the page No. 8

6. Connect AC power to “L1” and “L2” (CB1) —120 Volt, 60 Hz or as called for on controller data plate. 7. Connect remote normally open START push-button wires to terminals “13” and “14” (if used). 8. If deluge valve is used, remove jumper from terminals “16” and “17”. Connect wires from normally closed contact on deluge valve to terminals “16” and “17”. 9. Connect remote normally open shutdown interlock wires to terminals “15” and “16” (if used). A factory installed jumper will be install

Summary of the content on the page No. 9

Mark IIXG User Interface and Display SYSTEM STATUS 1 Ready 132 psi AC POWER AVAILABLE 1 11.7 0.8A 120~ 2 11.5 0.7A 118~ ALARM MAIN SWITCH IN AUTO 09-28-2009 14:37:06 MAIN SWITCH IN MANUAL SYSTEM PRESSURE LOW DIESEL ENGINE RUNNING ENGINE FAIL TO START ENGINE TEMPERATURE HIGH 2 3 ENGINE OIL PRESSURE LOW ENGINE OVERSPEED ENGINE ALTERNATE ECM ENGINE FUEL INJECTOR MALFUNCTION Esc Esc Enter Enter FUEL LEVEL LOW AUTOMATIC SHUTDOWN DISABLED 4 CHARGER MALFUNCTION Silence Silence BATTERY #1 TRO

Summary of the content on the page No. 10

Mark IIXG User Menu Structure Main Menu Settings System Setup Date & Time Timers Engine & Cranking Feat. Settings Opt. Settings Pressure Alarm Limits AC Failure Start (As ordered Display Time On Delay Time Units Control Overpressure Language/Units Date Min. Run Time Start Interlock Alarm with controller) # Attempts Sys DC Volt Set Low Press Aud Passwords Daylight Saving Stop Crank Time DC Volt Min Low Suction Auto Shtdwn Rest Time DC Volt Max Overpressure Main Sw Mis-Set Overspeed Term 1 AC Volt

Summary of the content on the page No. 11

Programming Notes The Firetrol Mark IIXG is multi-level password protected. User programmable functions are protected by a Level 1 password. LEVEL 1 PASSWORD 2 - 1 - 1 - 2 Indicates the level of password required to modify a setting. 1 Note: Many menu settings feature an “enable/disable” option. These options are indicated by a “ ” for enabled or a “x” for disabled. In many cases this can also be interpreted as “ ” for yes or a “x” for no. WARNING RISK OF PROPERY LOSS, DEATH OR

Summary of the content on the page No. 12

Mark IIXG User Menu Settings Note: Many menu settings feature an “enable/disable” option. These options are indicated by a " ” for enabled or a “x” for disabled. Indicates the level of password required to modify setting. 1 System Setup - Display SETTINGS SYSTEM SETUP DISPLAY BRIGHTNESS 1 Use and arrows to set desired display brightness. Press to confi rm. SETTINGS SYSTEM SETUP DISPLAY CONTRAST 1 Use and arrows to set desired display contrast. Press

Summary of the content on the page No. 13

SETTINGS DATE & TIME DAYLIGHT SAVING 1 Use arrows to enable or disable automatic Daylight Saving time adjustments. Press to confi rm. (+/-) Use arrows to set number of minutes to adjust for at the beginning or end of Daylight Saving time. Press to confi rm. (DST +) “Begin” - Hour Use arrows to set the hour of day that Daylight Saving time begins. Press to confi rm. (DST +) “Begin” - Day Use

Summary of the content on the page No. 14

SETTINGS PRESSURE OVERPRESSURE ALARM 1 Use arrows to enable or disable the overpressure alarm feature. Press to confi rm. Use arrows to set the pressure limit for the overpressure alarm. Press to confi rm. Limit SETTINGS PRESSURE RECORDING - DELTA 1 Use arrows to set pressure delta recording limit. Press to confi rm. Note: Pressure will be recorded whenever pressure changes by more than set limit. HOURLY Use

Summary of the content on the page No. 15

SETTINGS ALARM LIMITS MAX 1 Use arrows to set maximum voltage point for Battery Trouble alarm. Press to confi rm. SETTINGS ALARM LIMITS V MIN 1 Use arrows to set minimum voltage point for AC Voltage Low alarm. Press to confi rm. ENABLED 1 Use arrows to enable or disable the AC Voltage Low alarm. Press to confi rm. SETTINGS ALARM LIMITS V MAX 1 Use arrows to set maximum voltage point for AC Voltage Hi

Summary of the content on the page No. 16

FEATURE SETTINGS MANUAL TEST SETTINGS DURATION 1 Use arrows to set the minimum run time (duration) when manual test push-button is used (10 - 99 min.). Press to confi rm. PUMP RUN ALARM SETTINGS FEATURE SETTINGS AUDIBLE 1 Use arrows to enable or disable the audible alarm for Pump Run. Press to confi rm. COMMON ALARM 1 Use arrows to enable or disable the common alarm output (ALR relay) for Pump Run. Press to confi


Alternative user manuals
# User manual Category Download
1 Emerson ATEX User manual Automobile Parts 3
2 Emerson 3812 User manual Automobile Parts 1
3 Sony BP-GL95 User manual Automobile Parts 25
4 Sony BP-GL65 User manual Automobile Parts 2
5 Philips Epic 50PF9966 User manual Automobile Parts 3
6 Philips HTS3011 User manual Automobile Parts 2
7 Philips SDJ6040W User manual Automobile Parts 1
8 Philips SWA2151W User manual Automobile Parts 0
9 Philips Vortex Flow Meter F-2200 Series User manual Automobile Parts 3
10 A4 Tech. Sun StorageTekTM 4Gb FC Dual GbE HBA SG-XPCIE2FCGBE-E-Z User manual Automobile Parts 0
11 Aetna SATINELLE ICE HP6492 User manual Automobile Parts 0
12 Accel 140025 User manual Automobile Parts 15
13 Actron Cylinder Leakage Tester Kit 2509 User manual Automobile Parts 18
14 Actron 2501 User manual Automobile Parts 0
15 Actron Digital Multimeter CP7676 User manual Automobile Parts 28