White Rodgers pmnACM/ACB user manual

User manual for the device White Rodgers pmnACM/ACB

Device: White Rodgers pmnACM/ACB
Category: Air Cleaner
Manufacturer: White Rodgers
Size: 1.3 MB
Added : 10/16/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for White Rodgers pmnACM/ACB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with White Rodgers pmnACM/ACB.

For your convenience

If looking through the White Rodgers pmnACM/ACB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual White Rodgers pmnACM/ACB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual White Rodgers pmnACM/ACB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
White Rodgers pmnACM/ACB User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual White Rodgers pmnACM/ACB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to White Rodgers pmnACM/ACB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


 
Model Number
  
With Media Filter
ACM1000
ACM1200TM
ACM1400
ACM1600
ACM2000
ACM2000U
ACM2000X
No Media Filter
OWNER’S MANUAL
ACB1000
 Installation
 Operation
ACB1400
 Technical Repair Guide
 Repair and Upgrade Parts
ACB1600
ACB2000
Please read and familiarize yourself with the contents of this manual before
installing, operating or performing maintenance on the unit.
White-Rodgers is a division
PART NO. 37-6383C
of Emerson Electric Co.
Replaces 37-6383B
www.white

Summary of the content on the page No. 2

INTRODUCTION GUARANTEE The White-Rodgers Air Cleaner Compartment comes com- plete with a 5” media furnace air filter. This filter must be White-Rodgers will not assume any responsibility for changed every three months to maintain efficiency of the filter component failures due to incorrect installation procedures. and furnace system. For maximum efficiency, the compart- ment can be upgraded to a White-Rodgers Electronic Air RULES FOR SAFE INSTALLATION Cleaner. AND OPERATION Please read instructi

Summary of the content on the page No. 3

RAIL AND CLIPS 5" FILTER HOW THE AIR FILTER WORKS Dirty air flows through your return air ducts and enters the DIRTY AIR IN FILTERED AIR OUT compartment where particles (hair, lint, etc.) are removed by the filter. See figure 1. Filtered air re-enters to the supply duct system of your building. Figure 1 CONSTRUCTION OF THE AIR FILTER COMPARTMENT Not only is your air filter compartment easy to install, it is AIR FILTER COMPARTMENT also easy to maintain. Its basic components, and their 5" FILTER f

Summary of the content on the page No. 4

PREINSTALLATION LOCATING THE AIR FILTER Your air filter must be mounted in the return air duct of a central forced-air system, on the air entering side of your NOT TO EXCEED 20 furnace. (See Figure 3 for example.) AIR FLOW THIS CABINET Select a location that meets the following: CAN ACCEPT ELECTRONIC AIR CLEANER 1. The face of the filter will be at a right angle to the air OPTION stream. (SEE PAGE 7) 2. Allow 25” of clearance in front of the air filter compart- ment door to permit removal of fi

Summary of the content on the page No. 5

TYPICAL MOUNTING POSITIONS AIR FLOW AIR FLOW AIR FLOW Figure 5 Figure 7 Figure 6 BASEMENT FURNACE HIGHBOY FURNACE (LOWBOY) (Figure 5) (Figure 7) COUNTERFLOW FURNACE (Figure 6) Side installation. Filter is Filter is mounted horizon- mounted vertically, where tally in return plenum, just Filter is mounted horizontally return air enters side inlet above furnace. in return duct or plenum, just of furnace. above furnace. LESS THAN HIGHBOY FURNACE 7 INCHES OFFSET (Figure 8) Installation beneath furnac

Summary of the content on the page No. 6

INSTALLATION REMOVE OLD FILTER AND DISCARD (Figure 11) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT NOTE: The air filter cannot remove dirt from blower and Figure 11 ducts. INSTALLATION The following is a typical installation of the air filter on a “Highboy” furnace (Figure 7). 1. Place the air filter compartment on the floor. Stand it upright with the door facing you (Figure 2). If a horizontal installation is being planned, lay the com- partment on it

Summary of the content on the page No. 7

FLOOR Vertical Section CONDUIT Tape All Joints Wood Block DUCT Figure 15 AIR CLEANER Figure 16 MAINTENANCE For maximum efficiency, your air filter should be in- spected once a month and changed if dirt loading is ! CAUTION  heavy. When changing is required, the following proce- The fiber filter used in this compartment for air dure should be used: cleaning must be replaced every 90 days. Your 1. Remove door from air filter compartment by unscrew- heating and cooling efficiency will decrease due

Summary of the content on the page No. 8

NOTICE TO CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner or product containing a White-Rodgers Electronic Air Cleaner. Although White- Rodgers does not extend a warranty directly to consumers, White-Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White-Rodgers Products. To obtain more information about how your Wholesaler or Original Equipment Manu

Summary of the content on the page No. 9

Boîtier d’épurateur Modèle ACM/ACB Avec couche filtrante ACM1000 ACM1200TM ACM1400 ACM1600 ACM2000 ACM2000U ACM2000X Sans couche filtrante GUIDE DE L’UTILISATEUR ACB1000 •Installation • Exploitation ACB1400 • Guide technique de réparation •Pièces de rechange et de mise à niveau ACB1600 ACB2000 Prière de lire attentivement le manuel avant d’installer l’article, de l’utiliser ou d’en faire l’entretien. White-Rodgers est une division o PIÈCE N 37-6383C d’Emerson Electric Co. Remplace 37-6383B www.

Summary of the content on the page No. 10

INTRODUCTION GARANTIE Le boîtier d’épurateur White-Rodgers est vendu avec un filtre de 125 mm pour équipement de chauffage. On doit changer ce White-Rodgers se dégage de toute responsabilité pour le bris filtre aux trois mois afin d’assurer l’efficacité de l’épurateur et de composants découlant d’une installation incorrecte. de l’installation. Pour obtenir l’efficacité maximale, le boîtier se transforme en épurateur d’air électronique White-Rodgers à l’aide d’un ensemble de mise à niveau. DIRECT

Summary of the content on the page No. 11

RAIL ET AGRAFES RAIL AND CLIPS FILTRE DE 125 mm (5 po) FONCTIONNEMENT DU FILTRE À AIR L’air chargé entre dans les conduits de reprise et circulent jusqu’au boîtier, où les particules (cheveux, mousse, etc.) sont ENTRÉE D’AIR CHARGÉ SORTIE D’AIR FILTRÉ captées par le filtre (figure 1). L’air filtré regagne ensuite le réseau d’alimentation. Figure 1 CONSTRUCTION DE L’ÉPURATEUR BOÎTIER D’ÉPURATEUR L’épurateur est non seulement facile à installer, mais aussi FILTRE DE simple à entretenir. Voici une

Summary of the content on the page No. 12

INSTALLATION PRÉLIMINAIRE CHOIX DE L’EMPLACEMENT DE L’ÉPURATEUR L’épurateur s’installe dans le conduit de reprise d’air d’une NE PAS DÉPASSER 20 installation centrale à air pulsé, en amont du générateur d’air ÉCOULEMENT chaud. (Voir l’exemple à la figure 3.) CE BOÎTIER PEUT DE L’AIR AUSSI RECEVOIR UN FILTRE À AIR Choisir un emplacement conforme aux critères suivants: ÉLECTRONIQUE FACULTATIF 1. La face de l’épurateur est perpendiculaire à l’écoulement (VOIR PAGE 7) de l’air. 2. Il y a un dég

Summary of the content on the page No. 13

POSITIONS DE MONTAGE TYPIQUES ÉCOULEMENT ÉCOULEMENT DE L’AIR DE L’AIR ÉCOULEMENT DE L’AIR Figure 5 Figure 7 Figure 6 GÉNÉRATEUR À GÉNÉRATEUR DE SOUS-SOL CAISSONS SUPERPOSÉS (À CAISSONS JUXTAPOSÉS) GÉNÉRATEUR À (figure 7) (figure 5) CIRCULATION À CONTRE- Installer l’épurateur à l’horizontale COURANT (figure 6) Installation latérale. Installer dans le plénum de reprise d’air, juste l’épurateur à la verticale, là Installer l’épurateur à l’horizontale au-dessus du générateur. où la reprise d’air

Summary of the content on the page No. 14

INSTALLATION DÉMONTER ET JETER L’ANCIEN FILTRE (figure 11) REMARQUE : Il est possible que ce filtre se trouve à l’intérieur du générateur d’air chaud. NETTOYER LE COMPARTIMENT DU VENTILATEUR REMARQUE : L’épurateur n’est pas en mesure d’éliminer la saleté dans le ventilateur et les conduits. Figure 11 INSTALLATION Voici un exemple d’installation typique de l’épurateur sur un générateur à caissons superposés (figure 7). Boîtier 1. Déposer le boîtier d’épurateur sur le plancher. Le poser debout, av

Summary of the content on the page No. 15

MISE À NIVEAU ! PLANCHER Section verticale ALIMENTATION Calfeutrer les joints Bloc de bois CONDUIT Figure 15 ÉPURATEUR Figure 16 ENTRETIEN Pour assurer le meilleur rendement possible de l’épurateur, ! ATTENTION ▲ ATTEN- l’inspecter mensuellement et en changer le filtre s’il est sale. TION Lorsqu’un changement du filtre est requis, procéder de la façon Il est important de remplacer tous les 90 jours le filtre suivante: à fibres installé dans le boîtier. Lorsque le filtre est sale, les installati

Summary of the content on the page No. 16

AVIS AUX CONSOMMATEURS Épurateur d’air électronique White-Rodgers Cher consommateur, White-Rodgers tient à vous remercier d’avoir acheté un épurateur d’air électronique de marque White- Rodgers ou un produit qui en contient un. White-Rodgers ne propose pas de garantie qui protège directement les consommateurs. Cependant, l’entreprise garantit ses produits auprès des grossistes et des fabricants qui les utilisent. Pour savoir comment cette garantie peut vous avantager, nous vous prions de communi


Alternative user manuals
# User manual Category Download
1 White Rodgers 2SD2 User manual Air Cleaner 1
2 White Rodgers ACB1400 User manual Air Cleaner 1
3 White Rodgers ACB2000 User manual Air Cleaner 1
4 White Rodgers ACB1600 User manual Air Cleaner 0
5 White Rodgers ACM1000 User manual Air Cleaner 5
6 White Rodgers ACM1600 User manual Air Cleaner 0
7 White Rodgers ACB1000 User manual Air Cleaner 1
8 White Rodgers ACM2000 User manual Air Cleaner 3
9 White Rodgers ACM1400 User manual Air Cleaner 2
10 White Rodgers ECD1500B User manual Air Cleaner 1
11 White Rodgers ECS750B User manual Air Cleaner 1
12 White Rodgers CSC1000 User manual Air Cleaner 0
13 White Rodgers ECD1500W User manual Air Cleaner 1
14 White Rodgers ECS750W User manual Air Cleaner 0
15 White Rodgers MCD1200W User manual Air Cleaner 0
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9