Siemens 3RA2 user manual

User manual for the device Siemens 3RA2

Device: Siemens 3RA2
Category: Automobile Electronics
Manufacturer: Siemens
Size: 10.4 MB
Added : 8/17/2014
Number of pages: 58
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens 3RA2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens 3RA2.

For your convenience

If looking through the Siemens 3RA2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens 3RA2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens 3RA2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens 3RA2 User manual - Online PDF
Advertisement
« Page 1 of 58 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens 3RA2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens 3RA2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

© Siemens AG 2011
SIRIUS Motor Starters
6
Combination Starters &
Starters for Group Installation
SIRIUS 3RA2 Motor Starters
6/2 General data
3RA21 Direct-On-Line Starters
6/13 AC 50/60 Hz 110/120 V
6/15 24 V DC
3RA22 Reversing Starters
6/17 AC 50/60 Hz 110/120 V
6/19 24 V DC
6/21 Accessories
6/31 3RV29 Infeed System for
Motor Starters
For Operation in the Control Cabinet
SIRIUS 3RA6 Compact Starters
6/32 General data
3RA61, 3RA62 Compact Starters
6/40 3RA61 direct-on-line starters
6/41 3RA6

Summary of the content on the page No. 2

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data n Overview 3RA2 motor starters Tripping times The 3RA2 fuseless motor starters consist of the 3RV2 motor All 3RA2 motor starters described here are designed for normal starter protector and the 3RT2 electromechanical contactor. The starting, in other words for overload tripping times of less than devices are electrically and mechanically connected using pre- 1

Summary of the content on the page No. 3

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data 3RA2 complete units The fuseless motor starters can also be assembled easily by the customer. It is simply necessary to assemble the standard 3RV2 The 3RA2 fuseless motor starters can be ordered as preassem- motor starter protector, the 3RT2 contactor and the appropriate bled complete units for direct-on-line starting (3RA21) or for assembly kit. reversing duty (3RA22) with screw

Summary of the content on the page No. 4

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Communications integration using IO-Link This results in a significant reduction of wiring compared to the conventional parallel wiring method. The electrical connection is Motor starters can also be assembled with IO-Link for connec- made using standard cables. tion to the higher-level control system. For each starter this requires a communication-capable contactor onto which a T

Summary of the content on the page No. 5

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Direct-on-line starting • For standard rail mounting or screw fixing • Sizes S00 and S0 2 push-in lugs 2 push-in lugs 2 push-in lugs 3RV29 28-0B 3RV29 28-0B 3RV29 28-0B (only for screw (only for screw (only for screw mounting) mounting) mounting) Motor starter protector Motor starter protector Motor starter protector Size S00/S0 Size S00/S0 Size S00/S0 Screw terminals Spring-type term

Summary of the content on the page No. 6

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Direct-on-line starting • For 60 mm busbar systems • Sizes S00 and S0 60 mm busbar adapter 60 mm busbar adapter for screw terminals for spring-type terminals 8US12 51-5DS10 for S00 8US12 51-5DT11 for S00 8US12 51-5NT10 for S0 8US12 51-5NT11 for S0 Motor starter protector Size S00/S0 Screw terminals Motor starter protector Size S00/S0 Spring-type terminals Link module 3RA19 21-1DA00 fo

Summary of the content on the page No. 7

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Reversing duty • For standard rail mounting or screw fixing • Size S00 2 push-in lugs 2 push-in lugs 3RV29 28-0B 3RV29 28-0B (only for screw mounting) (only for screw mounting) Motor starter protector Motor starter protector Size S00 Size S00 Screw terminals Spring-type terminals Link module Link module 3RA19 21-1DA00 for S00 3RA29 11-2AA00 for S00 1 1 3 2 contactors 3 Size S00 Screw

Summary of the content on the page No. 8

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Reversing duty • For standard rail mounting • Size S0 RH assembly kit for reversing duty and standard rail mounting in size S0 For screw terminals: 3RA29 23-1BB1 For spring-type terminals: 1) 3RA29 23-1BB2 Comprising: 1 wiring kit 2 standard mounting rail adapters 2 connecting wedges 1) Also includes 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with

Summary of the content on the page No. 9

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Reversing duty • For 60 mm busbar systems • Sizes S00 and S0 RS assembly kit for reversing duty and busbar mounting Screw connection: 60 mm busbar adapter 3RA29 13-1DB1 for S00 For screw terminals: 3RA29 23-1DB1 for S0 8US12 51-5DS10 for S00 For spring-type connection: 8US12 51-5NT10 for S0 3RA29 13-1DB2 for S00 1) 3RA29 23-1DB2 for S0 For spring-type terminals: Comprising: 8U

Summary of the content on the page No. 10

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Order No. scheme Digit of the Order No. 1st - 4th 5th 6th 7th 8th 9th 10th 11th 12th 13th 14th 15th 16th 3rd @@@ @ @ @ 0 – @ @ @ @ @ – @ @ @ @ SIRIUS starters 3 R A SIRIUS 2nd generation 2 Type of starter (direct-on-line starter = 1, @ reversing starter = 2) Size (S00 = 1, S0 = 2) @ Setting range for overload release @ @ Design type and connection method @ Rated power at 460 V AC @ @

Summary of the content on the page No. 11

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data n More information Type 3RA2. 1 3RA2. 2 Size S00 S0 Number of poles 3 3 General data Standards IEC 60947-1, EN 60947-1 IEC 60947-2, EN 60947-2 IEC 60947-4-1, EN 60947-4-1 Max. rated current I (= max. rated operational current I ) A 16 32 n max e Permissible ambient temperature °C -20 ... +60 for operation °C -55 ... +80 during storage/transport Rated operational voltage U V 690 e Ra

Summary of the content on the page No. 12

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters General data Type SIRIUS 3RA2 Motor Starters Connection type Screw terminals Spring-type terminals Conductor cross-sections for main conductors Size S00 Motor starter protectors, contactors Motor starter protectors, contactors Terminal screw M3, Pozidriv size 2 -- Operating devices mm ! 5 ... 6 3.0 x 0.5 and 3.5 x 0.5 Prescribed tightening torque Nm 0.8 ... 1.2 -- Conductor cross-sections (min./

Summary of the content on the page No. 13

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA21 direct-on-line starters 50/60 Hz 110/120 V AC n Selection and ordering data Rated control supply voltage 50/60 Hz 110/120 V AC Direct-on-line With screw connections starting • The motor starter protector and contactor are mechanically and electrically connected by means of the link module. 1) • Auxiliary switches on the motor starter protector and the con- tactor can be easily fitted due t

Summary of the content on the page No. 14

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA21 direct-on-line starters 50/60 Hz 110/120 V AC Rated control supply voltage 50/60 Hz 110/120 V AC Direct-on-line With spring-type connection starting • These starters can be assembled in the field without tools by simply snapping the components together. Follow the simple component selection system to form a starter. 1) • Auxiliary switches on the motor starter protector and the con- tacto

Summary of the content on the page No. 15

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA21 direct-on-line starters 24 V DC Rated control supply voltage 24 V DC Direct-on-line With screw connections starting • The motor starter protector and contactor are mechanically and electrically connected by means of the link module. 1) • Auxiliary switches on the motor starter protector and the con- tactor can be easily fitted due to the modular system. • Integrated auxiliary switches: -

Summary of the content on the page No. 16

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA21 direct-on-line starters 24 V DC Rated control supply voltage 24 V DC Direct-on-line With spring-type connection starting • These starters can be assembled in the field without tools by simply snapping the components together. Follow the simple component selection system to form a starter. 1) • Auxiliary switches on the motor starter protector and the con- tactor can be easily fitted due t

Summary of the content on the page No. 17

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA22 reversing starters 50/60 Hz 110/120 V AC n Selection and ordering data Rated control supply voltage 50/60 Hz 110/120 V AC Reversing duty With screw connections • The motor starter protector and contactor are mechan- ically and electrically connected by means of the link module. 1) • Auxiliary switches on the motor starter protector and the contactor can be easily fitted due to the modular

Summary of the content on the page No. 18

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA22 reversing starters 50/60 Hz 110/120 V AC Rated control supply voltage 50/60 Hz 110/120 V AC Reversing duty With spring-type connection • These starters can be assembled in the field without tools by simply snapping the components together. Follow the simple component selection system to form a starter. 1) • Auxiliary switches on the motor starter protector and the contactor can be easil

Summary of the content on the page No. 19

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA22 reversing starters 24 V DC Rated control supply voltage 24 V DC Reversing duty With screw connections • The motor starter protector and contactor are mechan- ically and electrically connected by means of the link module. 1) • Auxiliary switches on the motor starter protector and the contactor can be easily fitted due to the modular system. • With the contactor S0, an integrated NO contact

Summary of the content on the page No. 20

© Siemens AG 2011 Combination Starters & Starters for Group Installation SIRIUS 3RA2 Motor Starters 3RA22 reversing starters 24 V DC Rated control supply voltage 24 V DC Reversing duty With spring-type connection • These starters can be assembled in the field without tools by simply snapping the components together. Follow the simple component selection system to form a starter. 1) • Auxiliary switches on the motor starter protector and the contactor can be easily fitted due to the modular


Alternative user manuals
# User manual Category Download
1 Siemens OpenAir GND Series User manual Automobile Electronics 7
2 Siemens 331-2856, 332-2856 AP 331-3 User manual Automobile Electronics 11
3 Siemens 3RA62 User manual Automobile Electronics 6
4 Sony CCD-TR99 User manual Automobile Electronics 4
5 Sony CCD-TR814 User manual Automobile Electronics 1
6 Sony CCD-TR714 User manual Automobile Electronics 1
7 Sony SSC-MX34 User manual Automobile Electronics 1
8 Sony CCD-TR614 User manual Automobile Electronics 1
9 Sony CCD-TR514 User manual Automobile Electronics 1
10 Philips LDH 0462/00 User manual Automobile Electronics 14
11 Acura Backup Sensors 08V67-SEP-2000-81 User manual Automobile Electronics 0
12 Acura Music Link 08A28-1H2-101 User manual Automobile Electronics 3
13 Acura Music Link 08A28-1H1-800 User manual Automobile Electronics 1
14 Acura Music Link bii32726-34939 User manual Automobile Electronics 0
15 Acura Music Link BII32604-34945 RDX User manual Automobile Electronics 0