Peerless Industries SMART MOUNT SF 16D user manual

User manual for the device Peerless Industries SMART MOUNT SF 16D

Device: Peerless Industries SMART MOUNT SF 16D
Category: Flat Panel Television
Manufacturer: Peerless Industries
Size: 0.35 MB
Added : 4/3/2014
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Peerless Industries SMART MOUNT SF 16D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Peerless Industries SMART MOUNT SF 16D.

For your convenience

If looking through the Peerless Industries SMART MOUNT SF 16D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Peerless Industries SMART MOUNT SF 16D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Peerless Industries SMART MOUNT SF 16D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Peerless Industries SMART MOUNT SF 16D User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Peerless Industries SMART MOUNT SF 16D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Peerless Industries SMART MOUNT SF 16D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation and Assembly:
Dedicated Flat Wall Mount for Flat Panel Screens
Models: SF 16D
Features:
• Ultra-slim design holds the screen flat against the wall
• Integrated security features provide effective theft deterrence
Max. Load Capacity: 200 lb (90.7 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 08-02-05 SHEET #: 202-9010-1

Summary of the content on the page No. 2

Note: Read entire instruction sheet before you start installation and assembly. WARNING • Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call Peerless customer care at 1-800-729-0307. • This product should only be installed by a qualified professional. • Make sure that the supporting surface will safely support the c

Summary of the content on the page No. 3

Parts List Description Qty. Part # AA wall plate 1 200-1797 interface plate 1 200-0860 BB CC #14 x 2.5" wood screw 4 5S1-015-C03 DD Alligator® anchor 4 590-0097 M10 x 1.5 x 15 mm socket head screw 4 520-9262 EE FF 4 mm security allen wrench 1 560-1146 AA BB EE DD CC FF ISSUED: 08-02-05 SHEET #: 202-9010-1 3 of 9

Summary of the content on the page No. 4

Installation to Single Wood Stud Wall WARNING • Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and hardware. Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based 1 on its edges, draw a vertical line down the stud’s center. Place wall plate (AA) on wall as a template, making sure that the three mounting holes are over the stud centerline. The top mounting hole should

Summary of the content on the page No. 5

Installation to Double Wood Stud Wall WARNING • Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and hardware. Wall plate (AA) can be mounted to two studs that are 16" apart. Use a stud finder to locate the edges of the studs. 1 Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each stud’s center. Place wall plate on wall as a template. The top mounting slots should be 2.5"

Summary of the content on the page No. 6

solid concrete cinder block Installation to Solid Concrete or Cinder Block WARNING • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica- tions. It is suggested that a standard electric drill on slow setting

Summary of the content on the page No. 7

Installing Interface Bracket to PLP Adapter Plate To prevent scratching the screen, set a cloth on a flat, level surface that will support the weight of the screen. Place 2 screen face side down. Attach the interface bracket (BB) to the PLP adapter plate (sold separately) using four M10 x 15 mm socket head screws (EE) as shown in figures 2.1 (portrait) or 2.2 (landscape). WARNING • Tighten screws so adapter brackets are firmly attached. Do not tighten with excessive force. Overtightening can cau

Summary of the content on the page No. 8

Installing Interface Bracket to LC Adapter Plate To prevent scratching the screen, set a cloth on a flat, level surface that will support the weight of the screen. Place 2 screen face side down. Attach the interface bracket (BB) to the LC adapter plate (sold separately) using four M5 screws provided with plate as shown in figures 2.3 (portrait) or 2.4 (landscape). WARNING • Tighten screws so adapter brackets are firmly attached. Do not tighten with excessive force. Overtightening can cause stres

Summary of the content on the page No. 9

Mounting and Removing Flat Panel Screen Note: Security screw may need to be loosened to avoid interference with wall plate. 3 Hook interface bracket (BB) onto wall plate (AA). Then slowly swing screen in as shown. Turn security screw, using security allen wrench (FF), clockwise at least six times to prevent screen from being removed as shown in detail 1. Screen can be adjusted horizontally if desired. Note: To lock the screen down, tighten security screw to wall plate using security allen wrench


Alternative user manuals
# User manual Category Download
1 Peerless Industries MIS374 User manual Flat Panel Television 2
2 Peerless Industries Peerless Slimline Universal Ultra-Thin Flat Wall Mount SUF660P User manual Flat Panel Television 0
3 Peerless Industries PEERLESS ULTRA-THIN FLAT MOUNT FOR 32" TO 56"* LCD FLAT PANEL SCREENS SUF650P User manual Flat Panel Television 2
4 Peerless Industries PARAMOUNT PP740-S User manual Flat Panel Television 0
5 Peerless Industries PLCM-UNL User manual Flat Panel Television 0
6 Sony 32LX1E User manual Flat Panel Television 81
7 Sony 4-180-179-16(1) User manual Flat Panel Television 13
8 Sony 4-106-868-11(1) User manual Flat Panel Television 7
9 Sony 32EX52X User manual Flat Panel Television 39
10 Sony 32EX42X User manual Flat Panel Television 24
11 Sony 37EX72X User manual Flat Panel Television 18
12 Sony 4-269-996-E5(1) User manual Flat Panel Television 2
13 Sony 4-116-578-11(1) User manual Flat Panel Television 1
14 Sony 32LX1 User manual Flat Panel Television 3
15 Sony 40EX72X User manual Flat Panel Television 22