Outback Power Systems FLEXMAX 80 user manual

User manual for the device Outback Power Systems FLEXMAX 80

Device: Outback Power Systems FLEXMAX 80
Category: Flat Panel Television
Manufacturer: Outback Power Systems
Size: 1.16 MB
Added : 9/30/2013
Number of pages: 92
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Outback Power Systems FLEXMAX 80. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Outback Power Systems FLEXMAX 80.

For your convenience

If looking through the Outback Power Systems FLEXMAX 80 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Outback Power Systems FLEXMAX 80 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Outback Power Systems FLEXMAX 80 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Outback Power Systems FLEXMAX 80 User manual - Online PDF
Advertisement
« Page 1 of 92 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Outback Power Systems FLEXMAX 80 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Outback Power Systems FLEXMAX 80. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TM
max 80
Maximum Power Point Tracking Charge Controller
User’s Guide
Installation, Programming and User’s Manual

Summary of the content on the page No. 2

Warranty Summary Dear OutBack Customer, Thank you for your purchase of OutBack products. We make every effort to assure our power conversion products will give you long and reliable service for your renewable energy system. As with any manufactured device, repairs might be needed due to damage, inappropriate use, or unintentional defect. Please note the following guidelines regarding warranty service of OutBack products: • Any and all warranty repairs must conform to the terms of the warra

Summary of the content on the page No. 3

The OutBack Power Systems FLEXmax 80 Maximum Power Point Tracking Charge Controller is ETL listed in North America to UL1741 (Inverters, Converters, Controllers, and Interconnection System Equipment for Use with Distributed Energy Resources). It is also in compliance with European Union standards EN 61000-6-1 and EN 61000-6-3 (see page 89). About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology. Our products include true sine wave inverter/char

Summary of the content on the page No. 4

TABLE OF CONTENTS SCOPE .......................................................................................................................................................................................................5 INTRODUCTION ..................................................................................................................................................................................5 INSTALLATION GUIDELINES AND SAFETY INSTRUCTIONS .................................

Summary of the content on the page No. 5

Vbatt Calibration ..........................................................................................................................................................................50 RTS Compensation .....................................................................................................................................................................50 Auto Restart ............................................................................................................

Summary of the content on the page No. 6

SCOPE The manual provides safety guidelines and installation information for the FLEXmax 80 Maximum Power Point Tracking Charge Controller. It does not provide information about specific brands of solar panels and supplies limited information on batteries. Contact the supplier or manufacturer of the solar panels or batteries for further information. INTRODUCTION FLEXmax 80 Maximum Power Point Tracking Charge Controller The OutBack FLEXmax 80 Maximum Power Point Tracking Charge Controller offe

Summary of the content on the page No. 7

OUTBACK FLEXmax 80 CHARGE CONTROLLER INSTALLATION GUIDELINES AND SAFETY INSTRUCTIONS This product is intended to be installed as part of a permanently grounded electrical system as shown in the system configuration sections (see pages 12-14) of this manual. The following important restrictions apply unless superseded by local or national codes: • The negative battery conductor should be bonded to the grounding system at only one point in the system. If a GFP is present, the battery negative

Summary of the content on the page No. 8

WARNING - WORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION. Design the battery enclosure to prevent accumulation and concentration of hydrogen gas in “pockets” at the top of the enclosure. Vent the battery compartment from the highest point to the outside. A sloped lid can also be used to direct the flow of hydrogen to the vent opening. CAUTION - To reduce risk of injury, charge only deep-cycle lead acid, lead antimo

Summary of the content on the page No. 9

THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller 8 PB

Summary of the content on the page No. 10

. Installing the FLEXmax 80 FLEXware DC Enclosures TheFLEXmax 80 is designed to attach directly to OutBack’s FLEXware 500 DC and FLEXware 1000 DC enclosures (FLEXware 500 shown) or attach to its own charge control brackets (FW-CCB, FW- CCB2, and FW-CCB2T). NOTE: Install the FLEXmax 80 in an upright posi- tion out of direct sunlight. To mount directly to a FLEXware DC enclosure: • Remove the fan cover and bottom cover from the FLEXmax 80. • Insert a #10 X 3/8” sheet metal screw in the to

Summary of the content on the page No. 11

. Determining Wire Sizes Open Circuit Voltage/Wire and Disconnect Size Maximum Open Circuit Voltage (VOC) • VOC is the unloaded voltage generated by the solar array. • Greater than 145VDC g FLEXmax 80 suspends operation to protect components • 150DC g max open circuit voltage with the coldest environment NOTE: Although the FLEXmax 80 shuts down at a voltage greater than 145VDC, it can withstand up to 150VDC from the array; anything higher than 150VDC will damage the FLEXmax 80). • As every

Summary of the content on the page No. 12

. FLEXmax 80  Wiring Connections Figure 1 FLEXmax 80 wiring compartment Use up to 2 AWG 2 (33.6 mm ) wire and torque to PV+ PV- BAT- BAT+ 35-inch pounds at Wire Lugs terminals. MATE/HUB RJ45 jack Chassis/Equipment Ground Lug Battery Remote Temp Sensor (RTS) RJ11 jack Programmable AUX Output Jack (supplies up to 200mA @ 12 VDC Screw holes for attaching FLEXmax 80 The PV (-) and BAT (-) terminals are connected internally. Only one negative wire may be needed to connect to the (-)

Summary of the content on the page No. 13

Figure 2 Single Charge Controller wiring diagram with 24 volt PV array  PB

Summary of the content on the page No. 14

Figure 3 Charge Controller Wiring Diagram with an FX, HUB 4, and an RTS  PB

Summary of the content on the page No. 15

Figure 4 Charge Controller with PV array ground fault protection wiring digram.  PB

Summary of the content on the page No. 16

How to Read the FLEXmax 80 Screen Diagrams Soft keys: (#1) (#2) (#3) (#4) Solid black indicates key is to be pressed: Down arrow will lead to the next screen: Up arrow points to one or more keys that will change a value: The keys correspond to any text immediately above them.  PB

Summary of the content on the page No. 17

. Powering Up The FLEXmax 80 power-up sequence first activates the unit and the SELECT VERSION screen (to de- termine a choice of English, Espanola, or Australian settings). A SYSTEM VOLTAGE screen soon follows. However, when it auto-detects the system’s battery voltage, in some instances the FLEXmax 80 might not reflect the correct system voltage (e.g., if a 36VDC system falls to a voltage range that could be misread as a 24VDC system). The SYSTEM VOLTAGE screens allow the user to adjust th

Summary of the content on the page No. 18

SelectV ersion The FLEXmax 80 screens are offered in English (standard Elijala Version screens) and Spanish. For Australian users, some of the USA charging values are of different voltages and the FLEXmax NEXTENTER ENTRA SEL 80 accommodates these. By pressing the soft key, the user can choose USA, Australia, or Espanola versions of the screens. After pressing the soft key, a password must be entered before selecting the screen version. Password Screen Press the

Summary of the content on the page No. 19

Are you sure? Press the soft key to confirm your choice or to return to the SELECT VERSION screen. USA NOYES The FLEXmax 80 auto detects the system’s battery voltage. To confirm this voltage, press the soft System Voltage Screen key. If incorrect, press the “g” soft key to select a battery voltage. The FLEXmax 80’s default values are based on SYTEM VOLTAGE a 12VDC system. Selecting a higher voltage system will 12 24 36 48 60 change all the

Summary of the content on the page No. 20

. S  tatus Screen The STATUS Screen displays system information. See page 63 for detailed information of the different Operational Modes. The optional OutBack MATE displays CC (Charge Controller) STATUS screens for convenient distant viewing from the installation location of the FLEXmax 80. Please see pages 65-67 to view the Charge Controller screens displayed on the MATE. The PV voltage will slowly rise to the battery voltage level even when the PV breaker is off – this is normal as the


Alternative user manuals
# User manual Category Download
1 Sony 32LX1E User manual Flat Panel Television 81
2 Sony 4-180-179-16(1) User manual Flat Panel Television 13
3 Sony 4-106-868-11(1) User manual Flat Panel Television 7
4 Sony 32EX52X User manual Flat Panel Television 39
5 Sony 32EX42X User manual Flat Panel Television 24
6 Sony 37EX72X User manual Flat Panel Television 18
7 Sony 4-269-996-E5(1) User manual Flat Panel Television 2
8 Sony 4-116-578-11(1) User manual Flat Panel Television 1
9 Sony 32LX1 User manual Flat Panel Television 3
10 Sony 40EX72X User manual Flat Panel Television 22
11 Sony 40NX710 User manual Flat Panel Television 14
12 Sony 46" BRAVIA KDL-46EX500 User manual Flat Panel Television 121
13 Sony 46EX620 User manual Flat Panel Television 9
14 Sony 40EX621 User manual Flat Panel Television 2
15 Sony 40NX700 User manual Flat Panel Television 25