Summary of the content on the page No. 1
NP-610X
X86 CISC-based Operator Interface Terminal with 10.4” Flat Panel Display
User’s Manual
Summary of the content on the page No. 2
Copyright .................................................................................................................. 3 Safety Instructions..................................................................................................... 4 Chapter 1 Introduction............................................................................................... 5 1.1 Introduction ................................................................................................... 5 Chapt
Summary of the content on the page No. 3
Copyright This document is copyrighted January l, 2008, by IVC Displays, Inc. All rights are reserved. IVC Displays, Inc. reserved the right to make improvements to the products described in this manual at any time. Specifications are thus subject to change without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of IVC Displays, Inc. Information provided in this manual is intended to be a
Summary of the content on the page No. 4
Safety Instructions Overview This section states the safety instructions, which must be followed when installing, operating and servicing the NP-610X. If neglected, physical injury and death may follow, or damage may occur to controller and related equipment. The material in this chapter must be studied before attempting any work on, or with, the unit. Warnings and Notes This manual distinguishes safety instructions. Warnings are used to inform of conditions, which can, if proper steps a
Summary of the content on the page No. 5
Chapter 1 Introduction 1.1 Introduction The MT612X is a miniature and compact platform that has excellent system performance and function. The x86 CPU Core provides the maximum compatibility with the vast amount of Internet content available while the intelligent integration of several other functions, including graphics, makes the AMD Geode™ LX processor a true system level multimedia solution. The NP-610X has a 10/100 Base-T Ethernet port for responsive open communications. Th
Summary of the content on the page No. 6
• On-board 512MB DDR-400MHz SDRAM • 44-pin IDE Interface (Disk-On-Module) • 3 serial ports (2-RS232, 1-RS485 2W/4W) • 2 USB ports full-speed port (12Mbps) • 1 Ethernet port (10/100 Base-T) • AC ‘97’ 16 bit sound output • Built in RTC • NEMA4 / IP65 Front Panel • Power input: 24 VDC, 0.8A maximum • Dimensions: (W x H x D): 259 x 201 x 51mm • Weight: 1.6 KGs (3.52 lbs.) • Operating temp: 0° ~ 45°C (32° ~ 113°F) • Relative humidity: 10% ~ 90% @ 40°C, non-condensing • Shock (oper
Summary of the content on the page No. 7
• Resolution: continuous • Light transmission: above 80% • Life: 1 million activation minimal Environmental Specifications • Operating temperature: 0° ~ 45°C (32° ~ 113°F) • Relative humidity: 10% ~ 90% @ 40°C, non-condensing • Shock (operation): 10 to 25Hz(X,Y,Z direction 2G 30minutes) • EMI: Complies FCC class A • CE: Complies with EN50081-2 and EN50082-2 standards • Front panel meets NEMA4 / IP65 Operating Systems • Windows CE 5.0 .NET • Windows XP Embedded 7
Summary of the content on the page No. 8
Chapter 2 Installation Instructions 2.1 Mounting Instructions 2.1.1 Location Considerations Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC output modules, contactors, starters and relays, and any other source of electrical interference are located away from the back of the unit. Particular note should be taken to the position of variable speed drives and switching power supplies. Their input and load cables should be screened to a ce
Summary of the content on the page No. 9
2.1.3 Environmental Considerations The NP-610X are to be used indoors as built in displays. Make sure that the displays are installed correctly and that the operating limits are followed (See Specifications). Do not operate the unit in areas subject to explosion hazards due to flammable gases, vapors or dusts. The unit should not be installed where fast temperature variations and/or high humidity are present. This will cause condensation of water in the device. Do not install th
Summary of the content on the page No. 10
2.2.1 Power Requirements The NP-610X can be powered by DC power only. The specified Power voltage range is +21 to 25 Volts DC. This insures compatibility with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 700mA. If the display does not come on within 2 seconds of power up, Fusing remove power. An internal fuse will prevent damage if the polarity Requirements of the
Summary of the content on the page No. 11
clockwise until it’s tight. Connect positive DC line to the ‘+24V’ terminal and the DC ground to the ‘GND‘ terminal. FUSE Replacement: The fuse use on MT608 is: BUSSMANN Fast Acting, Glass Tube Rating: 250VAC, 1A Size: 5x20mm Warning: 1. Make sure the power off before replace the fuse. 2. Do not replace the fuse with a different rating fuse. 2.2.2 Grounding Requirements Chassis ground must be used. DC ground is not directly coupled to Earth ground internally. It is preferable
Summary of the content on the page No. 12
2.2.4 Safety Guidelines This section presents recommended installation practices, and procedures. Since no two applications are identical, these recommendations should be considered as guidelines. Hardware Considerations WARNING! The system designer should be aware that devices in Controller systems could fail and thereby create an unsafe condition. Furthermore, electrical interference in an operator interface, such as an NP-610X, can lead to equipment start-up, which could result in pro
Summary of the content on the page No. 13
The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Association from NEMA ICS 3-304 2.3 Communications Connections The ports as you look at the back of the case, are the ports for connecting to a PLC or some external device (Controller Connectors). Cable Different cables are required for various devices. Requirements Restrict cable length to less than 500’ (150m) for RS485/422 Caution devices and 50’ (15m) for RS232 d
Summary of the content on the page No. 14
2.3.1 Connector COM 1 [RS232] 2.3.2 Connector COM2[RS232], COM3[RS485] and COM3[RS232] 14
Summary of the content on the page No. 15
NP-610X COM3 [RS-485] connect RS-485 2 wire Device COM1 [RS-485] RS-485 2 wire Device 9P D-SUB Female 4 Data+ Data+ 5 Data- Data- 1 GND NP-610X COM3 [RS-485] connect RS-485 4 wire Device COM1 [RS-485] RS-485 4 wire Device 9P D-SUB Female 1 Rx- Tx- RS485 Transmit 2 Rx+ Tx+ RS485 Transmit 3 Tx- Rx- RS485 Receive 4 Tx+ Rx+ RS485 Receive 5 GND 2.3.3 USB Master port The USB Master port can connect USB mouse and USB keyboard. The USB Master port suppor
Summary of the content on the page No. 16
2.4 CE Requirements EU directives that apply to the NP-610X Series: EMC Directive (89/336/EEC, 92/31/EEC, 93/68/EEC) electromagnetic emissions and immunity Machinery Directive (89/392/EEC, 91/368/EEC, 93/44/EEC, 93/ 68/EEC) machine safety NP-610X products will be CE-marked to indicate compliance with the EMC Directive. The NP-610X Series has been designed to operate satisfactorily in electromagnetic noise (immunity) and without emitting high levels of electrical noise into the en
Summary of the content on the page No. 17
Dimensions of NP-610X Cutout dimensions: NP-610X: 352mm [13.86”] W x 279mm [10.98”] H 17
Summary of the content on the page No. 18
18
Summary of the content on the page No. 19
Chapter 3 Windows CE.NET 3.1 Introduction The NP-610X series operator interface terminal is designed to serve on the Windows CE platform. Windows CE .NET is the successor to Windows CE 3.0. Designed from the ground up for the embedded marketplace, Windows CE .NET delivers a robust real-time operating system for rapidly building the next generation of smart mobile and small footprint devices. With a complete operating system feature set and end-to-end development environment, Windows CE .N
Summary of the content on the page No. 20
3.2.2 System Settings NP-610X provides an integrated utility for users to make basic setting of the machine. Step 1. Tap the “cecp” icon from Desktop. 2. Launch the System Settings Control Panel. 20