Furuno Satellite Compass SC-50/110 user manual

User manual for the device Furuno Satellite Compass SC-50/110

Device: Furuno Satellite Compass SC-50/110
Category: Fish Finder
Manufacturer: Furuno
Size: 0.78 MB
Added : 8/1/2013
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Furuno Satellite Compass SC-50/110. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Furuno Satellite Compass SC-50/110.

For your convenience

If looking through the Furuno Satellite Compass SC-50/110 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Furuno Satellite Compass SC-50/110 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Furuno Satellite Compass SC-50/110 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Furuno Satellite Compass SC-50/110 User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Furuno Satellite Compass SC-50/110 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Furuno Satellite Compass SC-50/110. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SATELLITE COMPASS
SC-50/110

Summary of the content on the page No. 2

The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, 9-52 Ashihara-cho, Nishinomi Nishinomiy ya 662-8580, JAPAN a 662-8580, JAPAN Tele Telep phone : hone : 0798-65-2111 0798-65-2111 Fa Fax x 0798-65-4200 0798-65-4200 :: FIRST EDITION : FIRST EDITION : NOV. NOV. 2005 2005 A All ri ll rig ghts reserved. hts reserved. Printed in Japan Printed in Japan Pub. No. Pub. No. SME-72510-A SME-72510-A *000158

Summary of the content on the page No. 3

Contents 1. Overview ...................................................................................... 1 2. Maintenance Menu ....................................................................... 2 1) MONITOR display ..............................................................................2 2) COMPASS display .............................................................................3 3) R MONITOR display .......................................................................

Summary of the content on the page No. 4

Summary of the content on the page No. 5

1. Overview The satellite compass, SC-50/110 calculates the heading by using the carrier signal of the GPS satellite signals. The system also calculates the heading with three rate sensors. When the satellite signal is blocked, the system outputs the heading data based on the rate sensor signal for a maximum of 5 minutes. The system always compares GPS heading with rate sensor heading. If the difference between two exceeds the preset value, an alarm is generated. The system needs abou

Summary of the content on the page No. 6

2. Maintenance Menu The system provides TEC menu or Maintenance menu for servicing. To show TEC menu, press and hold down MENU and ENT keys simultaneously until the menu appears after three beeps. It takes about 8 seconds to hear the third beep. Release the finger from MENU key, and then ENT key. If you release the finger from ENT key first, Main menu appears. This procedure is the same as SC-60/120. TEC MENU HDG SETUP MONITOR COMPASS R MONITOR R-CALIB

Summary of the content on the page No. 7

2) COMPASS display MASK-EL is used to set a minimum elevation angle of the satellite. The satellite of which elevation angle is lower than MASK-EL is not used for heading calculation. Default: 5 degrees. DO NOT change GPS DELAY, TIME CONST, SDEV-S, SDEV-C, and CHK NEW SV. COMPASS MASK-EL : 05° GPS DELAY : 0.220 SEC TIME CONST : 01 SEC SDEV-S : 0.0016 SDEV-C : 0.0069 CHK NEW SV : 0.20 Fig.4 COMPASS display 3) R MONITOR display “Rate sensor Monitor” d

Summary of the content on the page No. 8

4) R-CALIB display R-CALIB (Rate sensor Calibration) is used to enter the calibration value of the rate sensor at factory. It is not necessary to change this value when the rate sensor is replaced with new one. However, the value on top of the original sensor is written on top of the replacement sensor for future service. R-CALIB S1 : +0.0% S2 : +0.0% S3 : +0.0% Fig.6

Summary of the content on the page No. 9

5) RATE ERR display This menu sets the level to trigger the heading error alarms; NO HEADING OUTPUT and RATE ERROR. The system compares the output of the angular rate sensor with one obtained by the GPS signal. In the following example, an error is detected when the difference is 2.0º or more. An alarm is generated according to SHIFT CONT setting. In the example below, an alarm is generated when Roll sensor has four consecutive errors. YAW LIMIT: Used to detect Yaw output error. Success

Summary of the content on the page No. 10

7) ALARM display This menu sets the ALARM port signal. When ALARM MODE is set to “STOP,” the alarm signal is not sent out after acknowledgement. When selected “Continue,” the system continues to output the alarm signal. ALARMS ALARM MODE : STOP BUZZER FREQ : 2.075 kHz Fig. 10 8) ANALOG display This menu is used to test and compensate the motion sensor output signal. Set the desired angle on the ANGLE line and the set angle data is output from “ROLL” and “PITCH

Summary of the content on the page No. 11

The display consists of four indications; a circular graph which shows direction where the tracking error rate is the highest, a bar graph which shows tracking error rates in 12 directions, mutlipath indexes, and elapsed time. Circular graph: Shows the relation of 12 directions to the bow. The direction of the highest tracking error rate and its opposite direction are painted. Note that the sectors are painted even when no heading loss problem occurs. Bar graph: Shows tracking error r

Summary of the content on the page No. 12

10) MESSAGE display Error messages appear in the display. If RATE ERROR! appears, first check Installation Setup menu for correct setting: “Mounting” method and “Direction.” MESSAGES • NO HEADING OUTPUT ! • HEADING ERROR ! • RATE ERROR ! (YAW) Fig.14 Error Message display 11) REC MONI menu The REC MONI display, Figure 15 shows whether the system works normally or not. The GPS receiver having the least tracking error rate reads 1.0. The error rate of other receivers

Summary of the content on the page No. 13

3. Replacement of Battery The processor unit has a battery which backs up the RAM contents when the power is removed. When the voltage of the battery drops to 2.5 V, the message “BATTERY!” appears on the screen. To check the message, press [MENU] key and choose “MESSAGE.” The lifetime of the batteries is 3 to 5 years. CAUTION! Take care to avoid short-circuit of the battery. This could create a burn or fire hazard. Do not dispose of the battery in a fire or an incinerator; this may ca

Summary of the content on the page No. 14

5. Program Upgrade The three programs are used for the SC-50/110. Two programs are used in the processor unit and one program is in the display unit. The program numbers are tabulated below. Note that the program number of SC-50 is the same as SC-110, but they are different. The program for SC-50 cannot be overwritten by the one for SC-110 in the field and vise versa. (As of February 2005) Unit Board Program No. How to update MAIN board 205-1341-01.02 By using a PC Processor unit GP

Summary of the content on the page No. 15

2) CPU board (Display unit) To upgrade the program on the CPU board; 1. Connect the serial port of the PC to J15 on MAIN board in the processor unit. 2. Turn on the PC. Do not as yet turn on the SC-50/110. 3. Click the SCUP.bat file in the SC-50/110 program file. 4. Turn on the SC-50/110 after the message “TARGET POWER ON” on the PC screen. 5. “NOW LOADING” appears on the SC-50/110 display unit, while “Now Erasing,” and “xxx percent completed” appear during program upgrade on the PC scre

Summary of the content on the page No. 16

6. Maintenance 6.1 Adjustment 1) PWR board Switching regulator frequency is adjusted on PWR board, 20P8181 as below. Test Point GND Rating Adjuster TP2 TP1 120.0 kHz ± 10 kHz VR79 TP5 TP3 120.0 kHz ± 10 kHz VR80 2) MAIN board Vcc-c supply voltage to Rate sensor is adjusted by VR96 on MAIN board, 20P8178. Test Point GND Rating Adjuster #1 of J20 #2 of J20 5.0 V (Vcc-c) VR96 6.2 Line voltage check Line voltages are checked at J3 on the MAIN board. Line voltage Test Points on M

Summary of the content on the page No. 17

7. Location of Parts Rate Sensor Rate Sensor (Default: Yaw) (Default: Roll) Rate Sensor (Default: Pitch) PWR Board (20P8181) GPS Receivers (1, 2, 3 from Top) Main Board (20P8178) Fig. 17 Processor Unit with cover removed F1, 3A TP2 TP1 TP4 Fig.18 PWR Board, 20P8181 TP3 TP4 VR80 VR79 (not shown) 13

Summary of the content on the page No. 18

Log/Alarm Beacon Ext D Data out 6 ata out 1 to 5 Roll (above) Data In (AD-10) (from right, IEC or AD-10 Heading data) Pitch J3 J15 for system update R96 CR3 (CPU), Blinking TP1 No short bar BT1 J20 J19 J18 (for R&D) JP1 (CR2450-F2ST2L) Fig.19 MAIN Board, 20P8178 14

Summary of the content on the page No. 19

Appendix 1 Protection of ICs in Data Output Circuit Appendix 1 describes how to prevent ICs in the data output circuit temporarily. Refer to Appendix 2 for permanent remedy. Symptom U1, U2, and U3 in the heading output circuit are damaged. Cause Ground potential difference - The cable shield, or a signal return path between the circuit grounds of the equipment is not connected securely. The shield is connected to the unit through the cable clamp on SC-50/110, while the connector

Summary of the content on the page No. 20

1. Fabrication of Signal Cable The signal cable is fabricated as below. DO NOT hold back the cable shield over the armor. The installation manual will be revised. 80 Armor 70 Twist and cut. FV1.25-M3 Solder Grounding wire 40 Remove coat for clamping. 80 Armor Twist and cut. 70 FV1.25-M3 Solder Grounding wire 40 Vinyl tape Remove coat for clamping. Fig. 2 16


Alternative user manuals
# User manual Category Download
1 Furuno Fax30 User manual Fish Finder 12
2 Furuno BBWX1 User manual Fish Finder 2
3 Furuno FCV-292 User manual Fish Finder 162
4 Furuno FI-50 Series User manual Fish Finder 100
5 Furuno FCV-1150 User manual Fish Finder 116
6 Furuno FA30 User manual Fish Finder 18
7 Furuno Color Video Sounder FCV-291/292 User manual Fish Finder 145
8 Furuno FCV295 User manual Fish Finder 49
9 Furuno 525Tid-Tmd Tm Transducer W/Temp 525TID-TMD User manual Fish Finder 9
10 Furuno Fcv620 User manual Fish Finder 155
11 Furuno GP-50 User manual Fish Finder 25
12 Furuno GPS Navigator GP-50 MARK-2 User manual Fish Finder 148
13 Furuno Fr8062 User manual Fish Finder 8
14 Furuno GP32 User manual Fish Finder 413
15 Furuno Lh3000 User manual Fish Finder 10
16 Samsung HP-P5091 User manual Fish Finder 6
17 Samsung VP-D451 User manual Fish Finder 33
18 Samsung SP-R4232 User manual Fish Finder 4
19 Alpine Type-R SWR-M100 User manual Fish Finder 3
20 Audiovox Aca200w User manual Fish Finder 1