Trion AIR BOSS 60 user manual

User manual for the device Trion AIR BOSS 60

Device: Trion AIR BOSS 60
Category: Air Cleaner
Manufacturer: Trion
Size: 1.46 MB
Added : 6/27/2014
Number of pages: 29
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trion AIR BOSS 60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trion AIR BOSS 60.

For your convenience

If looking through the Trion AIR BOSS 60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trion AIR BOSS 60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trion AIR BOSS 60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trion AIR BOSS 60 User manual - Online PDF
Advertisement
« Page 1 of 29 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trion AIR BOSS 60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trion AIR BOSS 60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Field Assembled
ELECTRONIC
AIR CLEANER
AIR BOSS Model 60 Series
without
Integral Washing System
• INSTALLATION

• OPERATION
• SERVICE
For Model Numbers
60- ___-01
Electrostatic Precipitators for
Commercial & Industrial
Applications
101 McNeill Road • Sanford, NC 27330
(919) 775-2201 • Fax: (919) 774-8771 • (800) 884-0002
www.trioninc.com
MANUAL Form No. 61-0147B • Sept 01

Summary of the content on the page No. 2

TABLE OF CONTENTS SECTION I DESIGN For The System Design Engineer Page 1. General Description ...................................................................................................................................... 3 2. System Design and Floor Layout ................................................................................................................ 3 3. Outdoor Installations .........................................................................

Summary of the content on the page No. 3

SECTION I DESIGN To maintain the selected cleaning efficiency, it is important to assure that the total air volume (capacity in FOR THE SYSTEM DESIGN ENGINEER CFM) is uniformly distributed across the entire face area of the unit. However, since most air ducts are designed 1. General Description to handle air velocities greater than the rated velocity of Model 60 equipment consists of factory-assembled the air cleaner, it is necessary to properly transition any components to be “built-up” in the

Summary of the content on the page No. 4

C.) The basin floor should be properly pitched and finished to prevent puddling. (A) Framework D.) The cross members containing the anchoring studs to receive the air cleaner base frame must be even (B) Ionizing-Collecting Cells and level to provide a proper foundation for the metal framework base. (C) Controller with Power Supplies Where the installation site is not suitable for a poured (D) Accessories concrete basin, rust resistant metal pans may be used. The metal should withstand the weight

Summary of the content on the page No. 5

will be under negative pressure and should be made air The high voltage wiring consists of interconnecting tight to prevent infiltration of contaminated air. the ionizing-collecting cells into banks with bus bars, then wiring each bank of interconnected cells After the ductwork has been installed, clear remaining to its corresponding power supply with the high material or debris from inside ducts and bottom of voltage cable. cabinet. NOTE: IT IS IMPORTANT TO WIRE EACH BANK 4. Install Ionizing-Co

Summary of the content on the page No. 6

convenient location near the door. Those located that each alternate plate is charged while the inside are wired in series with the electrical intermediate plates are electrically grounded. interlocks and used as a safety measure to control the primary power to the high voltage power Periodically, depending on the type and concentration of supplies from inside the duct. Those located outside contamination in the air, the contaminate is washed control the duct lights. from the plates by manually

Summary of the content on the page No. 7

ionizing-collecting cells and inside the controller. The Air Boss controller (Optional) contains a digital Refer to Figure 14A. LED display for kilovolt and milliampere readings. The milliammeter should be observed on a routine D. Be sure that the drain lines from the Trion cabinet basis to be sure that it is reading within the drain basin are completely connected and properly prescribed operating range as marked on the data terminated. A trap or seal of some type should be plate. For those unit

Summary of the content on the page No. 8

At the start of the cleaning process, electrical The most common outage is a short in the switches that could be accidentally activated shall secondary circuit and is best located through the be locked out. Components of the fire suppression process of elimination. Symptoms are a flickering system (if installed) shall not be rendered indicating light accompanied by an arcing noise in inoperable during the cleaning process. the ionizing-collecting cell(s) or an indicating light that is not glowin

Summary of the content on the page No. 9

separately by disconnecting them, one at a time, from Although open circuits can occur in the secondary they their respective terminals at the power supply. When usually take place in the primary. If the unit contains a lead is found to be defective, replace it in its only one power supply and the indicating light does not entirety. Do not repair or splice. glow the outage is probably one of the following. (1) Supply line power to the control disconnected. b. If the light glows steady with the l

Summary of the content on the page No. 10

Troubleshooting Reference Chart PROBLEM/ PROBABLE LOCATION REASON - CORRECTION SYMPTOM CAUSE Ionizing Section of Cell 1. Dirty insulator(s) – Clean 2. Defective insulator(s) – Replace 3. Foreign Object Between Ionizing Bar and Ground electrode - Remove Collecting Section of Cell 1. Dirty insulator(s) - Clean 2. Defective insulator(s) – Replace Short Circuit 3. Foreign Material Bridging Plates - Remove Indicating Light 4. Bent Plates – Straighten or Replace Not Glowing High Voltage Leads 1. Disco

Summary of the content on the page No. 11

Summary of the content on the page No. 12

Summary of the content on the page No. 13

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Summary of the content on the page No. 16

Summary of the content on the page No. 17

Summary of the content on the page No. 18

Summary of the content on the page No. 19

Summary of the content on the page No. 20


Alternative user manuals
# User manual Category Download
1 Trion Air Boss 12 Series User manual Air Cleaner 0
2 Trion Air Boss 22 Series User manual Air Cleaner 0
3 Trion Air Boss 75 User manual Air Cleaner 1
4 Trion Air Boss DC-112 User manual Air Cleaner 0
5 Trion Air Boss ATS User manual Air Cleaner 1
6 Trion Air Boss DC-2 User manual Air Cleaner 2
7 Trion Air Boss DC-18 User manual Air Cleaner 4
8 Trion Air Boss DC-32 User manual Air Cleaner 0
9 Trion Air Boss DC-12 User manual Air Cleaner 0
10 Trion Air Boss DC-128 User manual Air Cleaner 0
11 Trion Air Boss DC-24 User manual Air Cleaner 0
12 Trion Air Boss DC-40 User manual Air Cleaner 2
13 Trion Air Boss DC-4 User manual Air Cleaner 0
14 Trion Air Boss DC-4M User manual Air Cleaner 1
15 Trion Air Boss DC-6M User manual Air Cleaner 0
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9