Summary of the content on the page No. 1
32- 5038- 01
User’s Information Guide
TM
Trane CleanEffects Whole House Air Filtration System
TM
Congratulations – Your TRANE CleanEffects air filtration system is the most advanced,
innovative and effective whole house air filtration system on the market today. It is designed to
TM
deliver what we call TRANE Air throughout your home. It delivers air that is meticulously filtered
and cleaned of up to 99.98% of allergens to provide maximum comfort. You and your family can
breathe easier than ev
Summary of the content on the page No. 2
User’s Information TM Figure 1. COMPONENTS OF THE TRANE CLEANEFFECTS 4 5 3 3 6 1 2 3 2 1 Fig. 1 1) Pre-filter - Traps large particles such as hair and lint 5) Power Door - The solid state power supply components before they can enter the cell section. that convert the 24 Volt AC to the high-voltage, direct current required to power the field charger and cells. 2) Field Charger - Charges the contaminants. Only to be Allows access to the collection cells, field charger and pre- service
Summary of the content on the page No. 3
User’s Information SEQUENCE OF OPERATION ! ▲ CAUTION You will need to turn off your air cleaner to This equipment should be inspected clean the filters. After cleaning, turn on the unit frequently and collected dirt removed from it by pressing and releasing the Power button. regularly to prevent excessive accumulation The backlit Power and Filter Reset button will that may result in flashover or risk of fire. illuminate along with first green LED indicating The field charger should only be remo
Summary of the content on the page No. 4
User’s Information WASHING not remove the door until all lights are off. Use low-pressure water spray, such as a sink ♦ Disconnect the power cable, if required, sprayer or garden hose to clean the cells. and place the door in a secure location. Stubborn residue like tobacco smoke may ♦ Rotate the two latches and remove the require warm water to be removed. door. PRE-FILTER CLEANING: Do NOT use soap or detergent in cleaning the The pre-filter can be vacuumed collection cells. (recommended) or was
Summary of the content on the page No. 5
User’s Information SET-UP MODE You can customize the performance of the air cleaner to meet the needs of your home and family using the set-up mode. Factory settings To enter the set-up mode, press and hold DIRTY BOTH the Power and the filter RESET buttons R3 R2 Field Charger Power for a minimum of 5 seconds. The LED display R1 Maximum will light up indicating the current settings as Y4 shown in Figure 3 to the right. Y3 Collection Cell Y2 6 Months Y1 You may select the cleaning intervals of t
Summary of the content on the page No. 6
User’s Information CHANGING THE SETTINGS While in the set-up mode, press the Power button once to begin cycling through the various setting options in the following order: DIRTY DIRTY DIRTY R3 R3 R3 Pre-Filter Cleaning Interval Setting R2 R2 R2 (Figure 4) R1 R1 R1 Y4 Y4 Y4 Y3 Y3 One or more of the GREEN LED lights will Y3 Y2 Y2 Y2 illuminate. To change the reminder interval Y1 Y1 Y1 time, press the Reset button until the desired G3 G3 G3 G2 G2 setting is indicated, and then press the Power G2 C
Summary of the content on the page No. 7
User’s Information FAULT INDICATORS DIRTY R3 The air cleaner has been designed to R2 continually monitor itself to insure it is working R1 properly. If it detects a problem, all four Y4 YELLOW LED lights will flash continuously. Y3 Y2 Y1 If this occurs, turn the unit off and clean both G3 the pre-filter and the collection cells to insure G2 no large material is trapped in the filters and CLEAN G1 causing the fault. DIRTY R3 If the unit detects any other type of fault, all R2 three RED LED ligh
Summary of the content on the page No. 8
Limited Warranty CleanEffects™ Whole House Air Cleaner TFD (Parts Only) This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the CleanEffects™ Air Cleaner is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada. If any part of your CleanEffects™ Air Cleaner fails because of a manufacturing defect within five years from the date of the original purchase,