Pelco C586M user manual

User manual for the device Pelco C586M

Device: Pelco C586M
Category: Electronic Keyboard
Manufacturer: Pelco
Size: 0.5 MB
Added : 9/18/2014
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Pelco C586M. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Pelco C586M.

For your convenience

If looking through the Pelco C586M user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Pelco C586M on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Pelco C586M to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Pelco C586M User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Pelco C586M but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Pelco C586M. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

–+ – +
COLOR BRIGHTNESS KBD4000V
MADE IN USA
C A M 0C LEA R
1 23
45 6
OPE N CLOSE
78 9
A U X
U NIT M AIN S P O T S E Q VIE W PAT T ER
N E AR FAR
LIVE/VCR
MONITOR
®
KBD4000V
®
Genex Multiplexer
Keyboard
Installation/
Operation Manual
C586M (9/99)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120

Summary of the content on the page No. 2

CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................4 DESCRIPTION ...................................................................................................................4 MODELS ....................................................................................................................5 INSTALLATION................................................................................................................

Summary of the content on the page No. 3

LIST OF ILLUSTRATIONS Figure Page 1 Rear Panel of KDB4000V Keyboard ..................................................................7 2 KBD4000V Interface Mounting Hole Dimensions ..............................................7 3 Connecting KBD4000V to a Multiplexer .............................................................7 4 Connecting KBD4000Vs to a Multiplexer Server ...............................................8 5 Connecting KBD4000 Series Keyboards to a Multiplexer Server ..........

Summary of the content on the page No. 4

IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After replace

Summary of the content on the page No. 5

MODELS KBD4000V Keyboard for pan, tilt and lens control of variable speed receivers. Includes 5-inch (12.7 cm) diagonal color monitor. 120 VAC, 60 Hz. KBD4000V-X Keyboard for pan, tilt, and lens control of variable speed receivers. Includes 5-inch (12.7 cm) diagonal color monitor. 230 VAC. 50 Hz. INSTALLATION NOTE: The KBD4000V The following parts are supplied: Keyboard in combination with a Genex multiplexer 1 KBD4000V Keyboard 1 +12 VDC power supply ® 1 KBD4000V Interface 1 RJ-45 wall block p

Summary of the content on the page No. 6

PROGRAMMING MODE Set switch 8 ON to program the multiplexer and camera presets and patterns from the keyboard. Set the switch OFF to disable programming. 3. Replace the cover on the back of the keyboard. 4. Peel off the protective coverings over the LED display and the LCD monitor on the keyboard. 5. Attach the KBD4000V Interface to the wall with the screws that are provided (refer to Figure 2). The interface must be within 6 feet (1.8 m) of the keyboard and the nearest suitable electrical outle

Summary of the content on the page No. 7

RJ-45 JACK PIN FUNCTIONS TABLE PIN 1 PIN FUNCTION 1 Tx+ 2 Tx- 3 +12 VDC 4 DC COMMON 5 GROUND 6 COMP. VIDEO 7 Rx- 8 Rx+ VIDEO POWER ON OFF 1 2 3 4 5 6 7 8 KEYBOARD 1 2 3 4 5 6 7 8 DIP SWITCH MONITOR ON/OFF (BENEATH COVER) SWITCH Figure 1. Rear Panel of KDB4000V Keyboard 2.5" (6.4 cm) Figure 2. KBD4000V Interface Mounting Hole Dimensions SPOT MAIN VCR IN COM OUT NNH OCC S AUX OUT IN ALARMS 110-240 V~50/60 Hz 12 3 4 5 6 7 8 9 10 11 12 1 314 15 16 SVHS SVHS MULTIPLE

Summary of the content on the page No. 8

VIDEO OUTPUTS LOCAL MUX(S) KEYBOARD 1 2 3 4 MULTIPLEXER SERVER R+ R- LIVE/VCR T- MONITOR AUX T+ R+ UNIT MAIN SPOT SEQ VIEW PATTERN PRESET ON OFF 123 NEAR FAR R- 456 OPEN CLOSE T- KBD4000V 789 T+ KBD4000V CAM 0 CLEAR POWER SUPPLY -+ -+ COLOR BRIGHTNESS KBD4000V MADE IN U.S.A. KBD4000V INTERFACE KBD4000V R+ R- LIVE/VCR T- MONITOR AUX T+ UNIT MAIN SPOT SEQ VIEW PATTERN PRESET ON OFF R+ 123 NEAR FAR R- 456 OPEN CLOSE T- KBD4000V 789 T+ KBD4000V CAM 0 CLEAR -+ -+ POWER SUPPLY COLOR BRIGHTNESS KBD4000

Summary of the content on the page No. 9

MULTIPLEXER SERVER LOCAL T+ T- R- R+ FROM MULTIPLEXER USER- SERVER SUPPLIED CABLE SECOND KBD FIRST KBD WALL BLOCK WALL BLOCK R+ TERMINAL TERMINAL R- 1 1 TX+ 2 2 T- TX- 3 3 T+ 4 4 R+ 5 5 GND R- TO KBD4000V 6 6 7 7 KBD4000V RX- T- 8 8 RX+ T+ KBD4000V POWER SUPPLY KBD4000V WALL BLOCK TERMINALS INTERFACE 45 12 VAC 12 VAC 3 6 WALL WALL TRANSFORMER TRANSFORMER 2 7 1 8 Figure 5. Connecting KBD4000 Series Keyboards to a Multiplexer Server MULTIPLEXER SERVER LOCAL FROM MULTIPLEXER SERVER USER- SUPPLIED

Summary of the content on the page No. 10

UNUSED Switches 4 and 5 are not used in the multiplexer server mode. They must be placed in the OFF position. TURBO MODE Set switch 6 ON to enable the turbo pan feature. Set the switch OFF to disable the turbo pan feature. CAMERA ADDRESS MODE There are two modes for addressing cameras: by addressing all the cameras consecutively from 1-256 (refer to Table D) or by addressing the cameras in groups of 16 according to the multiplexer they are connected to; for example, multiplexer 1, cameras 1-16;

Summary of the content on the page No. 11

OPERATION IMPORTANT NOTE ABOUT PROGRAMMING When the keyboard is plugged into a multiplexer or multiplexer server, the keyboard is ready to operate. However, some minimal programming may be required to make your system work. MULTIPLEXER The default settings for the duplex and simplex multiplexers are not the same, and it should not be assumed that there is nothing more to do after connecting the keyboard to the system. Below are the minimum things to check. 1. To allow the keyboard to communicate

Summary of the content on the page No. 12

IMPORTANT NOTE ABOUT DIFFERENCES IN SIMPLEX AND DUPLEX MULTIPLEXER MODES OF OPERATION The simplex multiplexer has three modes of operation: live, VCR, and record. • In the live mode, the main monitor can show live video both in full-screen or multiple-screen views. You cannot record in the live mode. The multiplexer’s DISPLAY/RECORD LED is OFF. • In the VCR mode, the main monitor will show full-screen or multiple-screen views (except PIP) of videotape playback. You cannot record in the VCR mode

Summary of the content on the page No. 13

20 12 34567 8 LIVE/VCR MONITOR AUX UNIT MAIN SPOT SEQ VIEW PATTERN PRESET ON OFF 123 NEAR FAR 456 OPEN CLOSE 11 * 19 789 THE TURBO PAN FEATURE * MAY BE DISABLED. PLACE CAM 0 CLEAR SWITCH 6 ON THE REAR PANEL DIP SWITCH BLOCK -+ -+ IN THE OFF POSITION. SEE FIGURE 1. KBD4000V COLOR BRIGHTNESS MADE IN U.S.A. 18 9 10 21 16 15 13 12 17 14 For complete operational instructions, refer to Table C, Operation Guide. For programming instructions (not covered below), refer to the Programming section. 1. LED

Summary of the content on the page No. 14

Table C. Operation Guide NOTE: References to switch 7 in this table refer to the switch behind the panel on the back of the keyboard. There are two modes for addressing cameras: by addressing all the cameras consecutively from 1-256 (switch 7 ON, refer to Table D) or by addressing the cameras in groups of 9 or 16 according to the multiplexer they are connected to (switch 7 OFF); for example, multiplexer 1, cameras 1-9 or 1-16; multiplexer 2, cameras 1-9 or 1-16, etc. OPERATION KEYBOARD COMMAND

Summary of the content on the page No. 15

Table C. Operation Guide (Continued) OPERATION KEYBOARD COMMAND RESULT Exits main tracking mode. Exit main tracking. 1. Go to the Advanced System Setup menu. 2. Move the joystick so the cursor highlights SPOT MONI- TOR DISPLAY items. 3. Press the OPEN key until either SEQUENCE or BLANK is displayed. 4. Exit the Advanced System Setup menu. Call a group of cameras 1. Press the MAIN MONITOR key. The green LED over the Displays the group of cameras on to the MAIN monitor. MAIN key lights. the MAIN

Summary of the content on the page No. 16

Table C. Operation Guide (Continued) OPERATION KEYBOARD COMMAND RESULT Zoom on a camera on 1. Press the MAIN MONITOR key. The green LED over the Stops a sequence if one is in the MAIN monitor. MAIN key lights. progress. Displays a 2X or 4X zoom of the camera selected on 2. Select the camera. the MAIN monitor. Addressing by Multiplexer (Switch 7 OFF) a. On the number pad, press the address number of the multiplexer (1-16 if the keyboard is connected to a multiplexer; 1-8 if the keyboard is conne

Summary of the content on the page No. 17

Table C. Operation Guide (Continued) OPERATION KEYBOARD COMMAND RESULT Run a sequence of 1. Press the SPOT MONITOR key. The green LED over Starts the sequence of individual cameras from one the SPOT key lights. cameras on the SPOT monitor. multiplexer on the SPOT monitor. (SPOT 2. Select a camera on the multiplexer that you want to MONITOR DISPLAY in sequence. the Advance System Setup menu must be in Addressing by Multiplexer (Switch 7 OFF) SEQUENCE.) a. On the number pad, press the address num

Summary of the content on the page No. 18

Table C. Operation Guide (Continued) OPERATION KEYBOARD COMMAND RESULT Starts sequencing the multiplexers Sequence multiplexers 1. Follow the steps under “Run a sequence of cameras connected to a server from one multiplexer on the MAIN monitor” or “Run a in numerical order, displaying the main monitor first, then the spot and sequence cameras sequence of cameras from one multiplexer on the on a multiplexer(s). SPOT monitor” to start sequencing the cameras on the monitor. Monitors to be displaye

Summary of the content on the page No. 19

Table C. Operation Guide (Continued) OPERATION KEYBOARD COMMAND RESULT Start auto scan with 1. Press the SPOT MONITOR key. The green LED over Starts auto scanning. 15-bit receiver. the SPOT key lights. 2. Select the camera. Addressing by Multiplexer (Switch 7 OFF) a. On the number pad, press the address number of the multiplexer (1-16 if the keyboard is connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press the UNIT key. The LED displays the address. b. On the num

Summary of the content on the page No. 20

Table C. Operation Guide (Continued) OPERATION KEYBOARD COMMAND RESULT Begin a pattern. 1. Press the MAIN or SPOT MONITOR key. The green The pattern operates until stopped. LED over the MAIN or SPOT key lights. When using the MAIN MONITOR, the SPOT MONITOR DISPLAY menu item in the Advanced System Setup menu must be set to TRACK MAIN (refer to the Advanced System Setup section). 2. Select the camera. Addressing by Multiplexer (Switch 7 OFF) a. On the number pad, press the address number of the m


Alternative user manuals
# User manual Category Download
1 Pelco Universal Keyboard KBD300A User manual Electronic Keyboard 1598
2 Sony PEGA-KB11 User manual Electronic Keyboard 4
3 Agilent Technologies 8904A User manual Electronic Keyboard 17
4 Agilent Technologies 03336-90011 User manual Electronic Keyboard 1
5 Adagio Teas KDP8865 User manual Electronic Keyboard 6
6 Adagio Teas PDP100 User manual Electronic Keyboard 2
7 Akai FACTORY PRESET MPK49 User manual Electronic Keyboard 61
8 Alesis QX49 User manual Electronic Keyboard 285
9 Alesis qs6.1 User manual Electronic Keyboard 507
10 Alesis DG8 User manual Electronic Keyboard 16
11 Alesis Q49 User manual Electronic Keyboard 139
12 Alesis GRIP Legacy Series Audio Processor Synthesizer User manual Electronic Keyboard 4
13 Alesis QSR 64 User manual Electronic Keyboard 99
14 Anritsu MG3700A User manual Electronic Keyboard 13
15 American Dynamics ADCC1100 User manual Electronic Keyboard 16