Summary of the content on the page No. 1
™
GP
Silent Air Purifier
Germicidal Protection
SI871 Instructions
INCLUDES IMPORTANT
SAFETY INFORMATION.
READ ALL INSTRUCTIONS
BEFORE USING THIS APPLIANCE.
SAVE THESE INSTRUCTIONS.
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Dear Sharper Image Customer, Thank you for your purchase of a Sharper Image product. We appreciate your business very much. Our goal is that you will be completely satisfied with this product’s quality and performance. We offer generous return privileges and excellent warranties on all our products. Since 1977, The Sharper Image has shared the fun of discovering innovative products that make life better and more enjoyable. We’ve been in business a long time because we are an exciting place
Summary of the content on the page No. 4
Summary of the content on the page No. 5
Table of Contents Warnings ...................................................................................6 Caution .....................................................................................8 Frequently Asked Questions ...................................................9 Frequently Asked Questions About OzoneGuard™ ...............10 General Instructions .................................................................11 Setup and Operation.......................................
Summary of the content on the page No. 6
Warnings Warning: To reduce the risk of fire, electric shock or injury when using any electrical appliance, basic precautions should always be observed, including the following: • This appliance operates at 110V AC and 50Hz or 60Hz only. • Connect to a polarized outlet only. • Plug is polarized with one blade wider than the other. The plug is only designed to fit in polarized outlet. Do not attempt to defeat this safety feature. • Use indoors only. • Unplug from outlet when not in use an
Summary of the content on the page No. 7
Warnings or against sharp edges or corners. • K eep the cord away from heated surfaces. • A damaged power cord must be replaced by qualified service personnel only. There are no user-serviceable parts inside the unit. Any attempt to open the unit will void the warranty and could lead to serious damage to the unit and/or personal injury to the user. • Before unplugging the unit from the outlet, turn off all the controls. • Do not unplug by pulling the cord. Grasp the plug itself, not th
Summary of the content on the page No. 8
Caution This product generates invisible ultraviolet light. To avoid overex- posure when the lamp is on, persons must stay at least one foot away from the unit if the total duration of exposure to the unit will be more than 30 minutes per day. Shorter duration of expo- sure at close proximity is safe. If the enclosure is damaged, do not use the product. Never stare at the UV-C lamp or place your face directly against the front or rear grill during operation. Failure to follow these warnings
Summary of the content on the page No. 9
Frequently Asked Questions How often is cleaning required? ® At least every two weeks, anytime The Sharper Image GP™ Silent Air Purifier makes an audible sound or the Cleaning Overdue indicator illuminates. How should it be cleaned? Wipe the removable collection grid with a damp cloth, paper towel or sponge. It is very important that the collection grid is completely dry before returning it to the main housing. What is the clean fresh scent I smell? The scent is ozone, (O ), a combination
Summary of the content on the page No. 10
™ Frequently Asked Questions About OzoneGuard What does OzoneGuard™ do? With the OzoneGuard in place, a significant portion of ground- level ozone inside the air purifier — including any trace levels of ozone by-product — is converted into oxygen before the cleaned air circulates back into the room. Why is the OzoneGuard™ smaller than the grill itself? The majority of the air output is directed toward the center of the grill and therefore a larger OzoneGuard isn’t necessary. Please read this
Summary of the content on the page No. 11
General Instructions Setup and Operation Place The Sharper Image GP at least twelve inches from the wall Blue Glow and in a location where children coming from cannot stare directly into the unit within the at a close range. unit indicates that the 12" Plug into a polarized 110V outlet. germicidal (Read Warnings for details.) lamp is operating. Switch the POWER CONTROL to the desired setting: Power ON: The unit will clean and circulate Control the air but the germicidal
Summary of the content on the page No. 12
Setup and Operation Switch the MODE CONTROL to the desired setting: LOW: For small rooms or rooms Mode where the door is usually closed. Control MEDIUM: For average-sized rooms. HIGH: For large rooms and higher traffic areas. To override the MODE CONTROL Boost setting and to run the unit at maximum power for five minutes, press BOOST. Your previously selected power level resumes after the five minutes. 12
Summary of the content on the page No. 13
Cleaning the Collection Grid This model features 3 highly charged collection blades separated by 2 oppositely charged “driver” blades. This improves the particle capture rate. Clean the grid every one or two weeks. As a reminder, the Cleaning Overdue indicator turns amber after two weeks. If the Cleaning Overdue indicator turns red, the unit has shut down because of excessive dirt or circuitry problems. In most cases, a thorough cleaning returns the unit to normal operation. 1. Before c
Summary of the content on the page No. 14
Cleaning the Collection Grid 3. Use a dry or slightly damp towel or sponge to quickly wipe the dust from each of the three collection bars. 4. Before replacing the grid, invert the entire unit two or three times. Note: The grid may also be washed with warm soapy water, then rinsed. If this method is used, allow 24 hours for the grid to completely dry before reinserting it into the main housing. Thorough Cleaning If the unit makes noise during operation, a thorough cleaning of
Summary of the content on the page No. 15
Thorough Cleaning 3. Use a hair dryer to blow dust from the interior or a vacuum to remove dust. Note: The OzoneGuard cannot be detached from the front grill. The OzoneGuard has sharp edges; use caution when cleaning. CAUTION: Do not use the product if the ionizing wires are broken or either grill appears damaged. Release-Tab Additional Information The exterior of the unit can be cleaned using a cloth or sponge and a solution of one part household bleach to five parts water or
Summary of the content on the page No. 16
Additional Information The majority of collected particles will gather on the removable stainless steel grid. Over time, debris will accumulate inside the unit. To access the inside, remove the front and rear grills. (See section titled “Thorough Cleaning.”) ® Sharper Image Silent Air Purifiers comply with current U.S. safety requirements for low ozone emissions for consumer products. We recommend that individuals with a history of respiratory disease consult with their doctor about possi
Summary of the content on the page No. 17
Germicidal Lamp Replacement Oil from fingers will reduce the germicidal performance of the UV-C lamp. If possible, use gloves or handle only by the metal area of the lamp. Otherwise, clean the lamp after installing to remove fingerprints and oils. To clean: Wipe the lamp, using a paper towel lightly dampened with rubbing alcohol or an ammonia-based cleaner (such as Windex brand). 1. Remove the cover by lifting up on the RELEASE-TAB at the bottom of the cover and sliding the cover up.
Summary of the content on the page No. 18
Statement of FCC Compliance — Model SI871 WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
Summary of the content on the page No. 19
Statement of FCC Compliance — Model SI871 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit diffe rent from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for assistance. 19
Summary of the content on the page No. 20
One-Year Warranty What Is Covered This warranty covers any defects in materials or workmanship, with the exceptions stated below. How Long Coverage Lasts This warranty runs for one year from the date of original purchase. What Is Not Covered This warranty does not cover damage caused by misuse or use other than as intended and described in the product instruction manual, or loss or damage to batteries or removable parts. What The Sharper Image Will Do The Sharper Image warrants this product a