Summary of the content on the page No. 1
ND-45503 (E)
ISSUE 2
PART OF STOCK # 151902
®
Office Data Programming Manual
FEBRUARY, 1998
NEC America, Inc.
Summary of the content on the page No. 2
LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its em- ployees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. term NEAX and D are registered trademarks of NEC Corporation. Copyright 1998 NEC America, Inc. Printed in USA.
Summary of the content on the page No. 3
ADD. No. ADD. No. PAGE No. PAGE No. 001 002 003 004 005 006 007 008 001 002 003 004 005 006 007 008 35 i ii 36 2.2 iii 37 38 iv 1 39 2.1 2.2 2 40 41 2.1 2.2 3 4 42 2.1 5 42-1 2.1 42-2 2.1 6 7 43 8 44 45 9 10 46 11 47 48 2.1 12 13 49 14 50 51 15 16 52 17 53 54 18 19 55 20 56 57 21 22 58 23 2.1 59 60 24 25 61 26 62 63 27 28 64 29 65 2.1 66 2.1 2.2 30 31 67 32 2.2 68 69 33 34 2.1 2.2 70 ADDENDUM-001 ADDENDUM-002 ADDENDUM-003 ADDENDUM-004 DATE JULY, 1998 DATE JANUARY, 1999 DATE DATE ADDENDUM-005 ADD
Summary of the content on the page No. 4
ADD. No. ADD. No. PAGE No. PAGE No. 001 002 003 004 005 006 007 008 001 002 003 004 005 006 007 008 71 108-1 2.2 72 2.1 108-2 2.2 73 2.1 2.2 109 110 74 75 111 76 112 77 113 78 114 79 115 80 116 81 117 82 118 83 119 84 120 85 2.2 121 122 86 2.1 87 123 88 124 89 125 90 2.1 126 91 127 92 128 93 129 94 130 95 131 96 132 97 133 98 134 99 135 100 136 101 137 102 138 103 139 104 140 105 141 2.1 106 142 2.1 107 142-1 2.1 108 2.1 2.2 142-2 2.1 ADDENDUM-001 ADDENDUM-002 ADDENDUM-003 ADDENDUM-004 DATE JULY
Summary of the content on the page No. 5
ADD. No. ADD. No. PAGE No. PAGE No. 001 002 003 004 005 006 007 008 001 002 003 004 005 006 007 008 143 144 145 146 147 148 149 150 151 152 153 154 155 156 2.1 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 ADDENDUM-001 ADDENDUM-002 ADDENDUM-003 ADDENDUM-004 DATE JULY, 1998 DATE JANUARY, 1998 DATE DATE ADDENDUM-005 ADDENDUM-006 ADDENDUM-007 ADDENDUM-008 DATE DATE DATE DATE NEAX2000 IVS Office Data Programming Manual Addendum Revision Sheet 3/3 ND-45503 (E) ISSUE 2
Summary of the content on the page No. 6
ND-45503 (E) ISSUE 2 FEBRUARY, 1998 NEAX2000 IVS Office Data Programming Manual TABLE OF CONTENTS Page CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. OUTLINE OF MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 7
LIST OF FIGURES Page Figure 1-1 Reference Manuals for Office Data Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 2-1 Module Configuration (Floor Standing) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 2-2 Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 LIST OF FIGURES ND-45503 (E) Page ii Revision 2.0
Summary of the content on the page No. 8
LIST OF TABLES Page Table 1-1 Data Programming Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Table 2-1 Port Assignment Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Table 2-2 Numbering Plan Data Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 2-3 Station Data Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 9
This page is for your notes. LIST OF TABLES ND-45503 (E) Page iv Revision 2.0
Summary of the content on the page No. 10
CHAPTER 1 INTRODUCTION 1. PURPOSE This manual is used for programming office data and designing the system layout required for customizing the NEAX2000 IVS (PBX). Before engaging in installation work, the installer is required to fill in the office data sheet, and draw the system layout and floor layout in this manual according to customer’s requirements. For additional information, refer to the Command Manual and Installation Procedure Manual. 2. OUTLINE OF MANUAL This manual consists of three
Summary of the content on the page No. 11
3. REFERENCE MANUALS For office data programming, other manuals are required to obtain various information as shown in Figure 1-1. REFERENCE MANUALS DESCRIPTION COMMAND MANUAL DATA PROGRAMMING METHOD GENERAL INFORMATION ON DATA PROGRAMMING COMMAND DESCRIPTION RESIDENT SYSTEM PROGRAM CIRCUIT CARD DESCRIPTION CIRCUIT CARD MANUAL CIRCUIT CARD MOUNTING CONDITIONS SWITCH SETTING OF CIRCUIT CARD INSTALLATION PROCEDURE GENERAL INFORMATION ON INSTALLING MANUAL SYSTEM INSTALLATION PROCEDURE Figure 1-1 R
Summary of the content on the page No. 12
4. DATA PROGRAMMING PROCEDURE Table 1-1 shows the procedure and the outline of the work related data programming for the system. The various data programmed in this manual are entered into the system through the CAT/MAT. Table 1-1 Data Programming Procedure STEP WORK REMARKS 1. Obtain the customer’s requirements, and fill in the Customer Specification Sheets on Chapter 2. 2. Allocate the LC, TRUNK and other interface cards to the Port Assignment Table on Chapter 2. Make a Bay Face Layout on
Summary of the content on the page No. 13
This page is for your notes. CHAPTER 1 ND-45503 (E) Page 4 Revision 2.0
Summary of the content on the page No. 14
CHAPTER 2 CUSTOMIZING DATA 1. GENERAL This chapter explains the general information for customizing data and the various tables for customer specifications such as numbering plan, station data and trunk data, etc., and sheets for designing the system layout such as Bay Face Layout. 2. GENERAL INFORMATION ON CUSTOMIZING DATA This section provides the information for customizing data in the Office Data Programming Manual. 2.1 Numbering Plan This table specifies the service feature access codes, tr
Summary of the content on the page No. 15
• Type of Telephone The type of station telephone set is specified as shown below. TYPE OF TEL DESCRIPTION DP ........................... Dial Pulse Telephone set PB ........................... DTMF Telephone set term term D ....................... D set • SERVICE CLASS-A/B/C Specify the service class (1-15) programmed in the Service Restriction Data Table. • RESTRICTION CLASS-DAY/NIGHT Specify the Trunk Restriction Class as shown below. 1: Unrestricted 2: Non-Restricted-1 3: No
Summary of the content on the page No. 16
• DP/PB Specify the type of address signal from/to distant office, as shown below. TYPE OF TEL DESCRIPTION DP......................... Dial Pulse PB ......................... DTMF Signal • KIND OF SIGNAL Specify the kind of signaling system such as Ring Down, Loop, E & M etc. at the line. 2.4 Station Hunting Group Data This data table requires the following data: • KIND OF STATION HUNTING Specify the kind of the Station Hunting System (Pilot/Circular/Switch Back). In the case of t
Summary of the content on the page No. 17
2.7 Port Assignment Table Specify the station number or trunk number corresponding to the LEN (Line Equipment Number) as shown in Table 2-1. The LEN means physical location number within the PIM. Table 2-1 Port Assignment Method CARD TO BE PORT ASSIGNMENT TABLE REMARKS ASSIGNED PN-4LC • For the PN-4DLC, specify the My Line Numbers of term PN-4DLC D as shown below. LT00 203 Station No. LEVEL 3 FXXX 0003 My Line Number 202 LEVEL 2 0002 201 LEVEL 1 0001 200 LEVEL 0 0000 PN-AUC • The station numb
Summary of the content on the page No. 18
Table 2-1 Port Assignment Method (Continued) CARD TO BE PORT ASSIGNMENT TABLE REMARKS ASSIGNED PN-AUC The trunk number must be assigned to the 1st LEN LT00 PN-2LDT (LEVEL 0) and/or 2nd LEN (LEVEL 1) of each LT slot. — PN-2ODT Not to be LEVEL 3 0003 assigned — LEVEL 2 0002 D001 LEVEL 1 Trunk No. 0001 (D000-D255) D000 LEVEL 0 0000 PN-2DAT • The card number must be assigned to the 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT LT00 slot. — Not to be • The card numbers are allocated to e
Summary of the content on the page No. 19
Table 2-1 Port Assignment Method (Continued) CARD TO BE PORT ASSIGNMENT TABLE REMARKS ASSIGNED PN-DK00 • The card number must be assigned to the 1st LEN LT00 (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot. — Not to be LEVEL 3 assigned 0003 • The card numbers of External Equipment Interface are Card No. allocated to each PIM as shown below. E801 LEVEL 2 (E800-E831) 0002 Card Number Accommodated in E800-E807 PIM0/PIM1 — LEVEL 1 0001 E808-E815 PIM2/PIM3 E816-E823 PIM4/PIM5 E800 LEVEL 0 0
Summary of the content on the page No. 20
Table 2-1 Port Assignment Method (Continued) CARD TO BE PORT ASSIGNMENT TABLE REMARKS ASSIGNED PN-2ILC • The ISDN circuit station number must be assigned to LT00 the 1st LEN (LEVEL 0) and/or 2nd LEN (LEVEL 1) of each LT slot. — Not to be LEVEL 3 0003 assigned — LEVEL 2 0002 201 LEVEL 1 ISDN Circuit 0001 Station No. 200 LEVEL 0 0000 ND-45503 (E) CHAPTER 2 Page 11 Revision 2.0